3Installing the Fireplace
Step 1. Locating the Fireplace
The diagram below shows space and clearance require- ments for locating a fireplace within a room.
A |
| B | C | D | E |
42” | 22” | 36” | 51” | 72” | |
Figure 2. | Fireplace Dimensions, Locations, | ||||
|
| and Space Requirements |
|
Clearance Requirements
The top, back, and sides of the fireplace are defined by
Minimum Clearances
from the Fireplace to Combustible Materials
| Inches | mm |
Glass Front | ........................ 36 | 914 |
Floor | 0 | 0 |
Rear | 1/2 | 13 |
Sides | 1/2 | 13 |
Top | 3 1/2 | 89 |
Ceiling* | 31 | 787 |
*The clearance to the ceiling is measured from the top of the unit, excluding the standoffs (see Figure 35).
The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the combustible construction, NOT from the screw heads that secure the unit together.
Minimum Clearances
from the Vent Pipe to Combustible Materials
| Inches | mm |
Vertical Sections | 1 | 25 |
Horizontal Sections |
|
|
Top | 3 | 75 |
Bottom | 1 | 25 |
Sides | 1 | 25 |
At Wall Firestops |
|
|
Top | 2 1/2 | 63.7 |
Bottom | 1/2 | 13 |
Sides | 1 | 25 |
For minimum clearances, see the direct vent termination clearance diagrams on pages 22 and 23 in this manual.