CHECKING GAS CONNECTIONS

INSTALLATION

Connecting Fireplace to Gas Supply (Cont.) Checking Gas Connections

13

INSTALLATION

Continued

4.Attach the flexible gas line to gas supply (see Figure 20). Check tightness of flexible gas line attached to gas regulator of fire- place (see Figure 20).

5.Check all gas connections for leaks. See Checking Gas Con- nections.

6.Replace log base assembly back into fireplace. Feed flexible gas line into fireplace base area while replacing log base as- sembly. Make sure the entire flexible gas line is in fireplace base area. Reattach log base assembly to fireplace with screws removed in step 2, page 12.

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using com- pressed air.

4.Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect fireplace and equipment shutoff valve to gas sup- ply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

To Fireplace

Gas Regulator

Pressure Testing gas Supply Piping system

Flexible Gas Line from Fireplace Gas Regulator

Equipment Shutoff Valve Provided by Installer

 

Propane/LP

To External

Regulator

 

 

Natural Gas

 

To Gas Meter

1.

Close equipment shutoff valve (see Figure 21).

2.

Pressurize supply piping system by either opening propane/LP

 

supply tank valve for propane/LP gas or opening main gas valve

 

located on or near gas meter for natural gas, or using com-

 

pressed air.

3.

Check all joints from gas meter to equipment shutoff valve for

 

natural gas or propane/LP supply to equipment shutoff valve

 

for propane/LP (see Figures 22 and 23, page 14). Apply non-

 

corrosive leak detection fluid to all joints. Bubbles forming

 

show a leak.

Figure 20 - Attaching Flexible Gas Lines Together

CHECKING GAS CONNECTIONS

Pressure Testing Fireplace Gas Connections WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

Manual background WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Manual background CAUTION: Make sure external regulator has been installed between propane/LP supply and fireplace. See guidelines under Connecting Fireplace to Gas Supply, page 12.

Pressure Testing gas Supply Piping system

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect fireplace with its main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pres- sures in excess of 1/2 psig will damage fireplace regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

4. Correct all leaks at once.

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 21).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to gas control valve (see Figures 22 or 23, page 14). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operating Fireplace, pages 15 through 17. Check all other internal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 16).

Equipment

ShutoffOpen

Valve

Closed

Figure 21 - Equipment Shutoff Valve

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual background

107172

Image 13
Contents WHAT TO DO IF YOU SMELL GAS OWNER’S OPERATION AND INSTALLATION MANUALDo not try to light any appliance UNVENTED VENT-FREEGAS FIREPLACESAFETY INFORMATION TABLE OF CONTENTSWARNINGS Continued PRODUCT IDENTIFICATIONSAFETY INFORMATION OPTIONAL REMOTE CONTROL ACCESSORY PRODUCT FEATURESSAFETY DEVICE OPTIONAL BLOWER ASSEMBLY ACCESSORYDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION PROVIDING ADEQUATE VENTILATIONUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building VENTILATION AIRVentilation Air From Outdoors AIR FOR COMBUSTION AND VENTILATIONINSTALLING HOOD INSTALLATIONBlower Accessories, and GA3555 Internal CHECK GAS TYPECONVENTIONAL FIREPLACE INSTALLATION INSTALLATION CLEARANCESIncluded with Mantel Accessory ASSEMBLING AND ATTACHING OPTIONAL BRASS TRIMINSTALLATION INSTALLATIONAccess Figure 10 - Installing Cabinet MantelMantel Clearances for Built-InInstallation BUILT-INFIREPLACE INSTALLATIONINSTALLATION ContinuedInstallation Items Needed INSTALLING GAS PIPING TO FIREPLACE LOCATIONINSTALLATION ContinuedInstallation Items Needed INSTALLATIONContinued 5/16 hex socket wrench or nut-driverPressure Testing Fireplace Gas Connections Pressure Testing gas Supply Piping systemCHECKING GAS CONNECTIONS INSTALLATIONINSTALLATION INSTALLING LOGSContinued OPERATING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS INSTALLATIONTO TURN OFF GAS TO APPLIANCE MANUAL LIGHTING PROCEDUREOPTIONAL REMOTE OPERATION Shutting Off HeaterGHRCTA Series Operation OPTIONAL BLOWER OPERATIONOPERATING FIREPLACE ContinuedPILOT FLAME PATTERN INSPECTING BURNERSFRONT BURNER FLAME PATTERN MAIN BURNERLOGS CLEANING AND MAINTENANCEOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYRefer to Air for Combustion and Venti Maintenance, pageTROUBLESHOOTING OBSERVED PROBLEMing Gas Connections, page visitTROUBLESHOOTING OBSERVED PROBLEMSPECIFICATIONS WIRING DIAGRAMREPLACEMENT PARTS SERVICE HINTSILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY EFS33NR, VSGF33NR4EFS33PR, VSGF33PR Shown Log Base AssemblyPARTS LIST PARTS LISTPART NUMBER EFS33NRILLUSTRATED PARTS BREAKDOWN FIREPLACE17 EFS33NR,VSGF33NR EFS33PR, VSGF33PRILLUSTRATED PARTS BREAKDOWN FireplacePARTS LIST FIREPLACE EFS33NR, VSGF33NR EFS33PR, VSGF33PRPARTS LIST PART NUMBERBLOWER ACCESSORY GA3700 & GA3700T SERIES ACCESSORIESEQUIPMENT SHUTOFF VALVE - GA5010 DUPLEX OUTLET KIT - GA3555 Not ShownCLEANING KIT - GCK Not Shown BRASS TRIM ACCESSORY - GA7090 Not ShownCORNER HEARTH BASE HARDWOOD HEARTH BASEWALL-MOUNTON/OFF SWITCH - GWMS2 WALL-MOUNTTHERMOSTAT SWITCH - GWMT1GHRCTA SERIES Not ShownOWNERS REGISTRATION FORM 2701 Industrial Drive P.O. Box Bowling Green, KY Postage RequiredPage LIMITED WARRANTY VENT-FREEGAS FIREPLACE KEEP THIS WARRANTYNOT A UPC Model Serial No Date Purchased