Desa EFS33NR, VSGF33PR Troubleshooting, Observed Problem, Possible Cause, Remedy

Page 20
TROUBLESHOOTING

20

TROUBLESHOOTING

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

When ignitor button is pressed, there is no

1.

Ignitor electrode not connected to igni-

1.

Reconnect ignitor cable

 

spark at ODS/pilot

 

tor cable

 

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched by any

 

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor to base

 

 

 

 

 

panel of log set. Nut is located behind

 

 

 

 

 

base panel.

 

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

 

6.

Ignitor electrode broken

6.

Replace piezo ignitor

 

 

7.

Ignitor electrode positioned wrong

7.

Replace piezo ignitor

 

 

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

 

spark at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

 

PILOT position

 

position

 

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

 

removed

 

 

5.

Depleted gas supply (propane/LP only)

5.

Contact local propane/LP gas company

 

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

 

Maintenance, page 19) or replace ODS/

 

 

 

 

 

pilot assembly

 

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

 

 

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

 

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

 

knob pressed in 30 seconds

 

 

3.

Equipment shutoff valve not fully open

3.

Fully open equipment shutoff valve

 

 

4.

Pilot flame not touching thermocouple,

4.

A) Contact local natural or propane/LP

 

 

 

which allows thermocouple to cool,

 

gas company

 

 

 

causing pilot flame to go out. This prob-

 

 

 

 

 

lem could be caused by one or both of

 

B) Clean ODS/pilot (see Cleaning and

 

 

 

the following:

 

Maintenance, page 19) or replace ODS/

 

 

 

A) Low gas pressure

 

pilot assembly

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten

 

 

 

trol valve

 

1/4 turn more

 

 

6.

Thermocouple damaged

6.

Replace thermocouple

 

 

7.

Control valve damaged

7.

Replace control valve

REMEDYManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundvisitManual backgroundManual background.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

107172

Image 20
Contents OWNER’S OPERATION AND INSTALLATION MANUAL WHAT TO DO IF YOU SMELL GASDo not try to light any appliance UNVENTED VENT-FREEGAS FIREPLACEWARNINGS TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION PRODUCT IDENTIFICATIONContinued PRODUCT FEATURES OPTIONAL REMOTE CONTROL ACCESSORYSAFETY DEVICE OPTIONAL BLOWER ASSEMBLY ACCESSORYPROVIDING ADEQUATE VENTILATION DETERMINING FRESH-AIRFLOW FOR HEATER LOCATIONUnusually Tight Construction Confined and Unconfined SpaceVENTILATION AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors AIR FOR COMBUSTION AND VENTILATIONINSTALLATION INSTALLING HOODBlower Accessories, and GA3555 Internal CHECK GAS TYPEINSTALLATION CLEARANCES CONVENTIONAL FIREPLACE INSTALLATIONIncluded with Mantel Accessory ASSEMBLING AND ATTACHING OPTIONAL BRASS TRIMINSTALLATION INSTALLATIONAccess Figure 10 - Installing Cabinet MantelBUILT-INFIREPLACE INSTALLATION Mantel Clearances for Built-InInstallationINSTALLATION ContinuedINSTALLING GAS PIPING TO FIREPLACE LOCATION Installation Items NeededINSTALLATION ContinuedINSTALLATION Installation Items NeededContinued 5/16 hex socket wrench or nut-driverPressure Testing gas Supply Piping system Pressure Testing Fireplace Gas ConnectionsCHECKING GAS CONNECTIONS INSTALLATIONContinued INSTALLING LOGSINSTALLATION FOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACELIGHTING INSTRUCTIONS INSTALLATIONMANUAL LIGHTING PROCEDURE TO TURN OFF GAS TO APPLIANCEOPTIONAL REMOTE OPERATION Shutting Off HeaterOPTIONAL BLOWER OPERATION GHRCTA Series OperationOPERATING FIREPLACE ContinuedINSPECTING BURNERS PILOT FLAME PATTERNFRONT BURNER FLAME PATTERN MAIN BURNERCLEANING AND MAINTENANCE LOGSTROUBLESHOOTING OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYMaintenance, page Refer to Air for Combustion and VentiTROUBLESHOOTING OBSERVED PROBLEMvisit ing Gas Connections, pageTROUBLESHOOTING OBSERVED PROBLEMWIRING DIAGRAM SPECIFICATIONSREPLACEMENT PARTS SERVICE HINTSLOG BASE ASSEMBLY EFS33NR, VSGF33NR4 ILLUSTRATED PARTS BREAKDOWNEFS33PR, VSGF33PR Shown Log Base AssemblyPARTS LIST PARTS LISTPART NUMBER EFS33NRFIREPLACE17 EFS33NR,VSGF33NR EFS33PR, VSGF33PR ILLUSTRATED PARTS BREAKDOWNILLUSTRATED PARTS BREAKDOWN FireplaceFIREPLACE EFS33NR, VSGF33NR EFS33PR, VSGF33PR PARTS LISTPARTS LIST PART NUMBERACCESSORIES BLOWER ACCESSORY GA3700 & GA3700T SERIESEQUIPMENT SHUTOFF VALVE - GA5010 DUPLEX OUTLET KIT - GA3555 Not ShownBRASS TRIM ACCESSORY - GA7090 Not Shown CLEANING KIT - GCK Not ShownCORNER HEARTH BASE HARDWOOD HEARTH BASEWALL-MOUNTTHERMOSTAT SWITCH - GWMT1 WALL-MOUNTON/OFF SWITCH - GWMS2GHRCTA SERIES Not ShownOWNERS REGISTRATION FORM Postage Required 2701 Industrial Drive P.O. Box Bowling Green, KYPage KEEP THIS WARRANTY LIMITED WARRANTY VENT-FREEGAS FIREPLACENOT A UPC Model Serial No Date Purchased