OPERATING FIREPLACE
Optional Remote Operation (Cont.) Optional Blower Operation
17
OPERATING FIREPLACE
Continued
GHRCTA Series Operation:
2b. Press the AUTO/ON/OFF button on the
| Increases Room | |
Shows Temperature | Temperature in | |
AUTO Mode | ||
Setting | ||
|
will show AUTO, ON, or OFF.
• In the ON mode, the burners will ignite. The heater is in |
manual mode when ON is lit. |
• In the AUTO mode, the thermostat in the |
unit controls the room temperature. To increase the room |
temperature, press the top arrow of the TEMP button. To |
lower the room temperature, press the bottom arrow of the |
TEMP button. At higher settings the heater will run longer. |
IMPORTANT: This remote control has been specially en- |
gineered to take an air temperature sample every minute |
The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected
Decreases Room
Temperature in
AUTO Mode
Turns Burners On or Off and Allows You to Choose the Auto Setting
in the auto mode. It will not respond immediately to the |
temperature setting being turned up or down. |
IMPORTANT: The |
be near the fireplace. Do not keep the |
control unit too close to the fireplace. The thermostat on |
the |
and turn the fireplace off. |
3. To turn the burners off, press the AUTO/ON/OFF button |
until OFF lights. The pilot will remain lit. |
IMPORTANT: To turn the pilot off, manually turn the con- |
trol knob on the fireplace to the OFF position. |
| Flame Adjustment Knob | |||
ON |
|
|
| OL |
N |
|
|
| |
|
|
|
| |
OFF | O |
|
| O |
|
|
| ||
REMOTE | T |
| F | |
O |
|
| ||
| F | HI | ||
| LIP |
| ||
Selector Switch in Remote |
| Control Knob in | ||
| On Position | |||
Position (Optional Remote |
|
Control)
Figure 32 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
Figure 33 - Thermostat
OPTIONAL BLOWER OPERATION
WARNING: This fireplace has a
Locate the blower switch by opening lower louver on fireplace. Blower switch is located at lower left inside louver door.
The GA3700TA
Note for GA3700TA Only: If you are using GA3700TA blower, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.
Follow installation instructions included with the blower accessory.
For morevisit www..com
107172