Desa EFS33NR visit, ing Gas Connections, page, Troubleshooting, Continued, Observed Problem

Page 22
ing Gas Connections, page 13)

22

TROUBLESHOOTING

TROUBLESHOOTING

Continued

visit WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Yellow flame in front burner during burner

1.

Not enough air

1.

Check burner(s) for dirt and debris. If

combustion

 

 

 

found, clean burner(s) (see Cleaning and

 

 

 

 

Maintenance, page 19)

 

2.

Gas regulator defective

2.

Replace gas regulator

Fireplace produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Low fuel supply (propane/LP only)

 

3.

Gas leak. See Warning statement

 

 

at top of page

1.Open window to ventilate room. Stop us- ing odor causing products while heater is running

2.Refill supply tank (propane/LP only)

3.Locate and correct all leaks (see Check- ing Gas Connections, page 13)

Fireplace shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural or propane/LP gas

 

 

 

 

company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 19)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

at top of page

 

ing Gas Connections, page 13)

 

2.

Control valve or gas control defective

2.

Replace control valve or gas control

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement

 

 

at top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 13)

Dark residue on logs inside of their fireplace

1.

Improper log placement

 

1.

Properly locate logs (see Installing Logs,

Note: After removing all causes of residue

 

 

 

 

page 14)

deposits, completely clean fireplace and ap-

2.

Drafts or other air currents affecting

2.

Eliminate source of drafts around heater

pliance off residue before reusing appliance

 

flame pattern

 

 

 

 

3.

Air holes at burner inlet blocked

 

3.

Clean out air holes at burner inlet. Peri-

 

 

 

 

 

odically repeat as needed

 

4.

Burner flame holes blocked

 

4.

Remove blockage or replace burner

For

 

visit

.

 

.com

107172

Image 22
Contents Do not try to light any appliance OWNER’S OPERATION AND INSTALLATION MANUALWHAT TO DO IF YOU SMELL GAS UNVENTED VENT-FREEGAS FIREPLACESAFETY INFORMATION TABLE OF CONTENTSWARNINGS Continued PRODUCT IDENTIFICATIONSAFETY INFORMATION SAFETY DEVICE PRODUCT FEATURESOPTIONAL REMOTE CONTROL ACCESSORY OPTIONAL BLOWER ASSEMBLY ACCESSORYUnusually Tight Construction PROVIDING ADEQUATE VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION Confined and Unconfined SpaceVentilation Air From Outdoors VENTILATION AIRVentilation Air From Inside Building AIR FOR COMBUSTION AND VENTILATIONBlower Accessories, and GA3555 Internal INSTALLATIONINSTALLING HOOD CHECK GAS TYPEIncluded with Mantel Accessory INSTALLATION CLEARANCESCONVENTIONAL FIREPLACE INSTALLATION ASSEMBLING AND ATTACHING OPTIONAL BRASS TRIMAccess INSTALLATIONINSTALLATION Figure 10 - Installing Cabinet MantelINSTALLATION BUILT-INFIREPLACE INSTALLATIONMantel Clearances for Built-InInstallation ContinuedINSTALLATION INSTALLING GAS PIPING TO FIREPLACE LOCATIONInstallation Items Needed ContinuedContinued INSTALLATIONInstallation Items Needed 5/16 hex socket wrench or nut-driverCHECKING GAS CONNECTIONS Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections INSTALLATIONINSTALLATION INSTALLING LOGSContinued LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING FIREPLACE INSTALLATIONOPTIONAL REMOTE OPERATION MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE Shutting Off HeaterOPERATING FIREPLACE OPTIONAL BLOWER OPERATIONGHRCTA Series Operation ContinuedFRONT BURNER FLAME PATTERN INSPECTING BURNERSPILOT FLAME PATTERN MAIN BURNERCLEANING AND MAINTENANCE LOGSPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM REMEDYTROUBLESHOOTING Maintenance, pageRefer to Air for Combustion and Venti OBSERVED PROBLEMTROUBLESHOOTING visiting Gas Connections, page OBSERVED PROBLEMREPLACEMENT PARTS WIRING DIAGRAMSPECIFICATIONS SERVICE HINTSEFS33PR, VSGF33PR Shown LOG BASE ASSEMBLY EFS33NR, VSGF33NR4ILLUSTRATED PARTS BREAKDOWN Log Base AssemblyPART NUMBER PARTS LISTPARTS LIST EFS33NRILLUSTRATED PARTS BREAKDOWN FIREPLACE17 EFS33NR,VSGF33NR EFS33PR, VSGF33PRILLUSTRATED PARTS BREAKDOWN FireplacePARTS LIST FIREPLACE EFS33NR, VSGF33NR EFS33PR, VSGF33PRPARTS LIST PART NUMBEREQUIPMENT SHUTOFF VALVE - GA5010 ACCESSORIESBLOWER ACCESSORY GA3700 & GA3700T SERIES DUPLEX OUTLET KIT - GA3555 Not ShownCORNER HEARTH BASE BRASS TRIM ACCESSORY - GA7090 Not ShownCLEANING KIT - GCK Not Shown HARDWOOD HEARTH BASEGHRCTA SERIES WALL-MOUNTTHERMOSTAT SWITCH - GWMT1WALL-MOUNTON/OFF SWITCH - GWMS2 Not ShownOWNERS REGISTRATION FORM Postage Required 2701 Industrial Drive P.O. Box Bowling Green, KYPage NOT A UPC KEEP THIS WARRANTYLIMITED WARRANTY VENT-FREEGAS FIREPLACE Model Serial No Date Purchased