Desa EFS33NR, VSGF33PR installation manual Installing Logs, Installation, Continued

Page 14
INSTALLING LOGS

14

INSTALLATION

Checking Gas Connections (Cont.) Installing Logs

INSTALLATION

Continued

Gas Control Valve

Equipment Shutoff Valve

Gas Meter

1.

Place front log (#1) on top of the grate. Make sure the notches

 

in the bottom of the log fit over the grate prongs (see Figure

 

24). Push back of log flush with metal grate bar.

2.

Rest middle log (#2) behind metal posts on front burner. Make

 

sure the grooves in the bottom of the log fit over the grate.

 

Bring the log forward next to the metal posts (see Figure 25).

3.

Slide the grooves in the back of the rear log (#3) against the

 

rear grate prongs. Make sure the peg on the log is on top (see

 

Figure 26).

4.

Place the crossover log (#4) on the rear log and the middle log.

 

Make sure the peg on the rear log is in the hole in the bottom

 

of the crossover log. The crossover log should fit in the cutout

 

of the middle log (see Figure 27).

Figure 22 - Checking Gas Joints for Natural Gas

Equipment

 

Shutoff

Propane/LP

Valve

Supply

 

 

Tank

Gas Control Valve

 

Figure 23 - Checking Gas Joints for Propane/LP Gas

INSTALLING LOGS

Manual background WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Manual background CAUTION: Do not remove the metal data plates attached to the heater base assembly. The data plates contain important safety and warranty information.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

5. Install fireplace screen by slipping notches of fireplace screen

over screws on front of fireplace (see Figure 28, page 15).

Manual background WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is in place before running fireplace.

 

 

 

Middle Log (#2)

Front Log (#1)

 

 

Groove

 

 

Groove

 

Notch

 

Metal

 

 

Post

 

 

 

 

Grate

 

 

 

 

Prongs

 

 

 

 

Metal Grate Bar

 

 

Metal Post

Grate

Figure 24 - Installing Front

Figure 25 - Installing Middle

Log (#1)

 

Log (#2)

 

Peg

Rear Log

 

 

Crossover

Groove

(#3)

 

 

Log (#4)

in Back

Groove

 

 

in Back

 

Hole

of Log

 

Grate

of Log

Cutout

 

 

 

Peg

Prong

 

 

 

Grate

 

 

 

 

 

 

Prong

 

 

Rear

Burner

Figure 26 - Installing Rear

Figure 27 - Installing Crossover

Log (#3)

Log (#4)

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundvisitManual backgroundManual background.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

107172

Image 14
Contents Do not try to light any appliance OWNER’S OPERATION AND INSTALLATION MANUALWHAT TO DO IF YOU SMELL GAS UNVENTED VENT-FREEGAS FIREPLACEWARNINGS TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION PRODUCT IDENTIFICATIONContinued SAFETY DEVICE PRODUCT FEATURESOPTIONAL REMOTE CONTROL ACCESSORY OPTIONAL BLOWER ASSEMBLY ACCESSORYUnusually Tight Construction PROVIDING ADEQUATE VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION Confined and Unconfined SpaceVentilation Air From Outdoors VENTILATION AIRVentilation Air From Inside Building AIR FOR COMBUSTION AND VENTILATIONBlower Accessories, and GA3555 Internal INSTALLATIONINSTALLING HOOD CHECK GAS TYPEIncluded with Mantel Accessory INSTALLATION CLEARANCESCONVENTIONAL FIREPLACE INSTALLATION ASSEMBLING AND ATTACHING OPTIONAL BRASS TRIMAccess INSTALLATIONINSTALLATION Figure 10 - Installing Cabinet MantelINSTALLATION BUILT-INFIREPLACE INSTALLATIONMantel Clearances for Built-InInstallation ContinuedINSTALLATION INSTALLING GAS PIPING TO FIREPLACE LOCATIONInstallation Items Needed ContinuedContinued INSTALLATIONInstallation Items Needed 5/16 hex socket wrench or nut-driverCHECKING GAS CONNECTIONS Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections INSTALLATIONContinued INSTALLING LOGSINSTALLATION LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING FIREPLACE INSTALLATIONOPTIONAL REMOTE OPERATION MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE Shutting Off HeaterOPERATING FIREPLACE OPTIONAL BLOWER OPERATIONGHRCTA Series Operation ContinuedFRONT BURNER FLAME PATTERN INSPECTING BURNERSPILOT FLAME PATTERN MAIN BURNERCLEANING AND MAINTENANCE LOGSPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM REMEDYTROUBLESHOOTING Maintenance, pageRefer to Air for Combustion and Venti OBSERVED PROBLEMTROUBLESHOOTING visiting Gas Connections, page OBSERVED PROBLEMREPLACEMENT PARTS WIRING DIAGRAMSPECIFICATIONS SERVICE HINTSEFS33PR, VSGF33PR Shown LOG BASE ASSEMBLY EFS33NR, VSGF33NR4ILLUSTRATED PARTS BREAKDOWN Log Base AssemblyPART NUMBER PARTS LISTPARTS LIST EFS33NRILLUSTRATED PARTS BREAKDOWN FIREPLACE17 EFS33NR,VSGF33NR EFS33PR, VSGF33PRILLUSTRATED PARTS BREAKDOWN FireplacePARTS LIST FIREPLACE EFS33NR, VSGF33NR EFS33PR, VSGF33PRPARTS LIST PART NUMBEREQUIPMENT SHUTOFF VALVE - GA5010 ACCESSORIESBLOWER ACCESSORY GA3700 & GA3700T SERIES DUPLEX OUTLET KIT - GA3555 Not ShownCORNER HEARTH BASE BRASS TRIM ACCESSORY - GA7090 Not ShownCLEANING KIT - GCK Not Shown HARDWOOD HEARTH BASEGHRCTA SERIES WALL-MOUNTTHERMOSTAT SWITCH - GWMT1WALL-MOUNTON/OFF SWITCH - GWMS2 Not ShownOWNERS REGISTRATION FORM Postage Required 2701 Industrial Drive P.O. Box Bowling Green, KYPage NOT A UPC KEEP THIS WARRANTYLIMITED WARRANTY VENT-FREEGAS FIREPLACE Model Serial No Date Purchased