Desa VSGF33PR Installation, Check Gas Type, Electrical Hookup, Installing Hood, Duplex Kit

Page 7
INSTALLATION

INSTALLATION

Check Gas Type

Electrical Hookup

Installing Hood

7

INSTALLATION

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

CHECK GAS TYPE WARNING: A qualified service person must in- stall fireplace. Follow all local codes.

ELECTRICAL HOOKUP WARNING: Never install the fireplace

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your fireplace. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

ELECTRICAL HOOKUP

(Models GA3700 Series and GA3700T Series

Blower Accessories, and GA3555 Internal

Duplex Kit)

This fireplace accepts a blower assembly with an electrical cord. The electrical cord is five feet in length. You must locate fireplace within reach of a 120 volt grounded electrical outlet. If not, you must install an electrical outlet within reach of fireplace power cord. The GA3555 outlet accessory may be used for built-in applications with blower accessory installed.

INSTALLING HOOD

Install hood to rail already installed in fireplace as shown in Figure 5. Use 3 Phillips screws provided.

(Models GA3700 Series and GA3700T Series CAUTION: This fireplace creates warm air cur- rents. These currents move heat to wall surfaces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited, to tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

Hood

Rail

Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials.

Use the dimensions shown for rough openings to create the easiest installation. See Built-In Fireplace Installation, pages 10 and 11.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6.

IMPORTANT: Make sure the fireplace is level. If fireplace is not level, log set will not work properly.

Screw

Figure 5 - Installing Hood

Blower Accessories, and GA3555 InternalFor moreDuplex Kit)INSTALLING HOODManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual background

107172

Image 7
Contents UNVENTED VENT-FREEGAS FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUALWHAT TO DO IF YOU SMELL GAS Do not try to light any applianceSAFETY INFORMATION TABLE OF CONTENTSWARNINGS Continued PRODUCT IDENTIFICATIONSAFETY INFORMATION OPTIONAL BLOWER ASSEMBLY ACCESSORY PRODUCT FEATURESOPTIONAL REMOTE CONTROL ACCESSORY SAFETY DEVICEConfined and Unconfined Space PROVIDING ADEQUATE VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION Unusually Tight ConstructionAIR FOR COMBUSTION AND VENTILATION VENTILATION AIRVentilation Air From Inside Building Ventilation Air From OutdoorsCHECK GAS TYPE INSTALLATIONINSTALLING HOOD Blower Accessories, and GA3555 InternalASSEMBLING AND ATTACHING OPTIONAL BRASS TRIM INSTALLATION CLEARANCESCONVENTIONAL FIREPLACE INSTALLATION Included with Mantel AccessoryFigure 10 - Installing Cabinet Mantel INSTALLATIONINSTALLATION AccessContinued BUILT-INFIREPLACE INSTALLATIONMantel Clearances for Built-InInstallation INSTALLATIONContinued INSTALLING GAS PIPING TO FIREPLACE LOCATIONInstallation Items Needed INSTALLATION5/16 hex socket wrench or nut-driver INSTALLATIONInstallation Items Needed ContinuedINSTALLATION Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections CHECKING GAS CONNECTIONSINSTALLATION INSTALLING LOGSContinued INSTALLATION FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING FIREPLACE LIGHTING INSTRUCTIONSShutting Off Heater MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE OPTIONAL REMOTE OPERATIONContinued OPTIONAL BLOWER OPERATIONGHRCTA Series Operation OPERATING FIREPLACEMAIN BURNER INSPECTING BURNERSPILOT FLAME PATTERN FRONT BURNER FLAME PATTERNLOGS CLEANING AND MAINTENANCEREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEOBSERVED PROBLEM Maintenance, pageRefer to Air for Combustion and Venti TROUBLESHOOTINGOBSERVED PROBLEM visiting Gas Connections, page TROUBLESHOOTINGSERVICE HINTS WIRING DIAGRAMSPECIFICATIONS REPLACEMENT PARTSLog Base Assembly LOG BASE ASSEMBLY EFS33NR, VSGF33NR4ILLUSTRATED PARTS BREAKDOWN EFS33PR, VSGF33PR ShownEFS33NR PARTS LISTPARTS LIST PART NUMBERFireplace FIREPLACE17 EFS33NR,VSGF33NR EFS33PR, VSGF33PRILLUSTRATED PARTS BREAKDOWN ILLUSTRATED PARTS BREAKDOWNPART NUMBER FIREPLACE EFS33NR, VSGF33NR EFS33PR, VSGF33PRPARTS LIST PARTS LISTDUPLEX OUTLET KIT - GA3555 Not Shown ACCESSORIESBLOWER ACCESSORY GA3700 & GA3700T SERIES EQUIPMENT SHUTOFF VALVE - GA5010HARDWOOD HEARTH BASE BRASS TRIM ACCESSORY - GA7090 Not ShownCLEANING KIT - GCK Not Shown CORNER HEARTH BASENot Shown WALL-MOUNTTHERMOSTAT SWITCH - GWMT1WALL-MOUNTON/OFF SWITCH - GWMS2 GHRCTA SERIESOWNERS REGISTRATION FORM 2701 Industrial Drive P.O. Box Bowling Green, KY Postage RequiredPage Model Serial No Date Purchased KEEP THIS WARRANTYLIMITED WARRANTY VENT-FREEGAS FIREPLACE NOT A UPC