Desa VSGF33PR Operating Fireplace, Lighting Instructions, For Your Safety Read Before Lighting

Page 15
LIGHTING INSTRUCTIONS

INSTALLATION

Installing Logs (Cont.)

OPERATING FIREPLACE

For Your Safety Read Before Lighting Lighting Instructions

15

INSTALLATION

Continued

LIGHTING INSTRUCTIONS

Notches

Screws for

Mounting Screen

Figure 28 - Installing Fireplace Screen

OPERATING FIREPLACE

FOR YOUR SAFETY

READ BEFORE LIGHTING

OPERATING FIREPLACE WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

FOR YOUR SAFETY WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information in column 1.

2.Make sure equipment shutoff valve is fully open.

3.Set selector switch in OFF position.

Manual background WARNING: Burners will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

4.Press in and turn control knob clockwise Manual background to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counterclockwise Manual background to the PILOT position. Press in control knob for five (5) seconds (see Figure 29).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

Manual background CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Ignitor Button

Flame Adjustment

Knob

 

O

O

L

 

IL T

O

AUTO

P

 

F

N

 

 

 

 

OFF

F

 

 

O

 

 

ON

 

HI

 

 

 

 

Selector Switch

Control Knob

Figure 29 - Control Knob and Ignitor Button Location (Shown as Supplied, No Control Options)

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual background

107172

Image 15
Contents UNVENTED VENT-FREEGAS FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUALWHAT TO DO IF YOU SMELL GAS Do not try to light any applianceTABLE OF CONTENTS SAFETY INFORMATIONWARNINGS PRODUCT IDENTIFICATION ContinuedSAFETY INFORMATION OPTIONAL BLOWER ASSEMBLY ACCESSORY PRODUCT FEATURESOPTIONAL REMOTE CONTROL ACCESSORY SAFETY DEVICEConfined and Unconfined Space PROVIDING ADEQUATE VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION Unusually Tight ConstructionAIR FOR COMBUSTION AND VENTILATION VENTILATION AIRVentilation Air From Inside Building Ventilation Air From OutdoorsCHECK GAS TYPE INSTALLATIONINSTALLING HOOD Blower Accessories, and GA3555 InternalASSEMBLING AND ATTACHING OPTIONAL BRASS TRIM INSTALLATION CLEARANCESCONVENTIONAL FIREPLACE INSTALLATION Included with Mantel AccessoryFigure 10 - Installing Cabinet Mantel INSTALLATIONINSTALLATION AccessContinued BUILT-INFIREPLACE INSTALLATIONMantel Clearances for Built-InInstallation INSTALLATIONContinued INSTALLING GAS PIPING TO FIREPLACE LOCATIONInstallation Items Needed INSTALLATION5/16 hex socket wrench or nut-driver INSTALLATIONInstallation Items Needed ContinuedINSTALLATION Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections CHECKING GAS CONNECTIONSINSTALLING LOGS INSTALLATIONContinued INSTALLATION FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING FIREPLACE LIGHTING INSTRUCTIONSShutting Off Heater MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE OPTIONAL REMOTE OPERATIONContinued OPTIONAL BLOWER OPERATIONGHRCTA Series Operation OPERATING FIREPLACEMAIN BURNER INSPECTING BURNERSPILOT FLAME PATTERN FRONT BURNER FLAME PATTERNLOGS CLEANING AND MAINTENANCEREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEOBSERVED PROBLEM Maintenance, pageRefer to Air for Combustion and Venti TROUBLESHOOTINGOBSERVED PROBLEM visiting Gas Connections, page TROUBLESHOOTINGSERVICE HINTS WIRING DIAGRAMSPECIFICATIONS REPLACEMENT PARTSLog Base Assembly LOG BASE ASSEMBLY EFS33NR, VSGF33NR4ILLUSTRATED PARTS BREAKDOWN EFS33PR, VSGF33PR ShownEFS33NR PARTS LISTPARTS LIST PART NUMBERFireplace FIREPLACE17 EFS33NR,VSGF33NR EFS33PR, VSGF33PRILLUSTRATED PARTS BREAKDOWN ILLUSTRATED PARTS BREAKDOWNPART NUMBER FIREPLACE EFS33NR, VSGF33NR EFS33PR, VSGF33PRPARTS LIST PARTS LISTDUPLEX OUTLET KIT - GA3555 Not Shown ACCESSORIESBLOWER ACCESSORY GA3700 & GA3700T SERIES EQUIPMENT SHUTOFF VALVE - GA5010HARDWOOD HEARTH BASE BRASS TRIM ACCESSORY - GA7090 Not ShownCLEANING KIT - GCK Not Shown CORNER HEARTH BASENot Shown WALL-MOUNTTHERMOSTAT SWITCH - GWMT1WALL-MOUNTON/OFF SWITCH - GWMS2 GHRCTA SERIESOWNERS REGISTRATION FORM 2701 Industrial Drive P.O. Box Bowling Green, KY Postage RequiredPage Model Serial No Date Purchased KEEP THIS WARRANTYLIMITED WARRANTY VENT-FREEGAS FIREPLACE NOT A UPC