Desa VSGF33PR Wiring Diagram, Specifications, Replacement Parts, Service Hints, Technical Service

Page 23
WIRING DIAGRAM

WIRING DIAGRAM SPECIFICATIONS REPLACEMENT PARTS SERVICE HINTS TECHNICAL SERVICE

23

WIRING DIAGRAM

Note: For proper operation of optional accessories, the wires from the switch to the control must be connected exactly as shown.

A

 

UT

O

OF

ON

F

 

Thermopile

SPECIFICATIONS

MODELS EFS33NR & VSGF33NR

Btu (Variable)

20,000/33,000

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

Minimum*

5"

Shipping Weight

122 lbs.

* For input adjustment

 

MODELS EFS33PR & VSGF33PR

Btu (Variable)

20,000/33,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Manifold

7.9" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

13"

Minimum*

11"

Shipping Weight

122 lbs.

* For input adjustment

 

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-866-672-6040. When calling DESA Inter- national, have ready

your name and address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International at 1-866-672-6040 for referral information. When calling DESA International, have ready

model number of your fireplace

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low for propane/LP unit

You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting.

If so, contact DESA International’s Technical Service Department at 1-866-672-6040.

You can also visit DESA International’s technical services web site at www.desatech.com.

SPECIFICATIONSFor moreMODELS EFS33NR & VSGF33NRMODELS EFS33PR & VSGF33PRREPLACEMENT PARTSvisit www.PARTS UNDER WARRANTYPARTS NOT UNDER WARRANTYSERVICE HINTS.comWhen Gas Pressure Is Too LowTECHNICAL SERVICEManual backgroundManual background

107172

Image 23
Contents UNVENTED VENT-FREEGAS FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUALWHAT TO DO IF YOU SMELL GAS Do not try to light any applianceWARNINGS TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION PRODUCT IDENTIFICATIONContinued OPTIONAL BLOWER ASSEMBLY ACCESSORY PRODUCT FEATURESOPTIONAL REMOTE CONTROL ACCESSORY SAFETY DEVICEConfined and Unconfined Space PROVIDING ADEQUATE VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION Unusually Tight ConstructionAIR FOR COMBUSTION AND VENTILATION VENTILATION AIRVentilation Air From Inside Building Ventilation Air From OutdoorsCHECK GAS TYPE INSTALLATIONINSTALLING HOOD Blower Accessories, and GA3555 InternalASSEMBLING AND ATTACHING OPTIONAL BRASS TRIM INSTALLATION CLEARANCESCONVENTIONAL FIREPLACE INSTALLATION Included with Mantel AccessoryFigure 10 - Installing Cabinet Mantel INSTALLATIONINSTALLATION AccessContinued BUILT-INFIREPLACE INSTALLATIONMantel Clearances for Built-InInstallation INSTALLATIONContinued INSTALLING GAS PIPING TO FIREPLACE LOCATIONInstallation Items Needed INSTALLATION5/16 hex socket wrench or nut-driver INSTALLATIONInstallation Items Needed ContinuedINSTALLATION Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections CHECKING GAS CONNECTIONSContinued INSTALLING LOGSINSTALLATION INSTALLATION FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING FIREPLACE LIGHTING INSTRUCTIONSShutting Off Heater MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE OPTIONAL REMOTE OPERATIONContinued OPTIONAL BLOWER OPERATIONGHRCTA Series Operation OPERATING FIREPLACEMAIN BURNER INSPECTING BURNERSPILOT FLAME PATTERN FRONT BURNER FLAME PATTERNLOGS CLEANING AND MAINTENANCEREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEOBSERVED PROBLEM Maintenance, pageRefer to Air for Combustion and Venti TROUBLESHOOTINGOBSERVED PROBLEM visiting Gas Connections, page TROUBLESHOOTINGSERVICE HINTS WIRING DIAGRAMSPECIFICATIONS REPLACEMENT PARTSLog Base Assembly LOG BASE ASSEMBLY EFS33NR, VSGF33NR4ILLUSTRATED PARTS BREAKDOWN EFS33PR, VSGF33PR ShownEFS33NR PARTS LISTPARTS LIST PART NUMBERFireplace FIREPLACE17 EFS33NR,VSGF33NR EFS33PR, VSGF33PRILLUSTRATED PARTS BREAKDOWN ILLUSTRATED PARTS BREAKDOWNPART NUMBER FIREPLACE EFS33NR, VSGF33NR EFS33PR, VSGF33PRPARTS LIST PARTS LISTDUPLEX OUTLET KIT - GA3555 Not Shown ACCESSORIESBLOWER ACCESSORY GA3700 & GA3700T SERIES EQUIPMENT SHUTOFF VALVE - GA5010HARDWOOD HEARTH BASE BRASS TRIM ACCESSORY - GA7090 Not ShownCLEANING KIT - GCK Not Shown CORNER HEARTH BASENot Shown WALL-MOUNTTHERMOSTAT SWITCH - GWMT1WALL-MOUNTON/OFF SWITCH - GWMS2 GHRCTA SERIESOWNERS REGISTRATION FORM 2701 Industrial Drive P.O. Box Bowling Green, KY Postage RequiredPage Model Serial No Date Purchased KEEP THIS WARRANTYLIMITED WARRANTY VENT-FREEGAS FIREPLACE NOT A UPC