TROUBLESHOOTING

21

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

 

 

Burner does not light after ODS/pilot is lit

1.

Inlet gas pressure is too low

1.

Contact local natural or propane/LP gas

 

 

 

 

 

 

company

 

 

 

2.

Burner orifice(s) clogged

2. Clean burner(s) (see Cleaning and Mainte-

 

 

 

 

 

 

nance, page 19) or replace burner orifice(s)

 

 

 

3.

Burner orifice diameter is too small

3.

Replace burner orifice

 

 

 

4.

Thermopile leads disconnected or im-

4.

Reconnect leads (see Wiring Diagram,

 

 

 

 

properly connected

 

page 23)

 

 

 

5.

Burner will not come on in remote po-

5.

Replace battery in transmitter and receiver

 

 

 

 

sition

 

 

 

 

 

 

 

 

 

 

Delayed ignition of one or both burners

1.

Manifold pressure is too low

1.

Contact local natural or propane/LP gas

 

 

 

 

 

 

company

 

 

 

2.

Burner orifice(s) clogged

2.

Clean burner(s) (see Cleaning and Main-

 

 

 

 

 

 

tenance, page 19) or replace burner

 

 

 

 

 

 

orifice(s)

 

 

 

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Main-

 

 

 

 

 

 

tenance, page 19) or replace burner

 

 

 

 

 

 

orifice(s)

 

 

 

2.

Damaged burner

2.

Replace damaged burner

 

 

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

 

 

Maintenance, page 19)

 

 

 

2.

Gas regulator defective

2.

Replace gas control

 

 

 

3.

Residues from manufacturing processes

3.

Problem will stop after a few hours of

 

 

 

 

and logs curing

 

operation

 

 

 

 

 

 

 

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Venti-

 

 

 

 

 

 

lation requirements (page 4)

 

 

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

 

burners are lit

 

when burners are cold

 

let warm up for a minute

 

 

 

2.

Air in gas line

2.

Operate burners until air is removed

 

 

 

 

 

 

from line. Have gas line checked by lo-

 

 

 

 

 

 

cal natural or propane/LP gas company

 

 

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

 

 

ances (see pages 8 through 11)

 

 

 

4.

Dirty or partially clogged burner

4.

Clean burners (see Cleaning and Main-

 

 

 

 

orifice(s)

 

tenance, page 19) or replace burner

 

 

 

 

 

 

orifice(s)

 

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. may turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

Remote does not function (GHRC and GHRCTA only)

1.Battery is not installed. Battery power is low

1.Replace 9-volt batteries in receiver and remote control

Refer to Air for Combustion and Venti-For moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual background

107172

Image 21
Contents WHAT TO DO IF YOU SMELL GAS OWNER’S OPERATION AND INSTALLATION MANUALDo not try to light any appliance UNVENTED VENT-FREEGAS FIREPLACETABLE OF CONTENTS SAFETY INFORMATIONWARNINGS PRODUCT IDENTIFICATION ContinuedSAFETY INFORMATION OPTIONAL REMOTE CONTROL ACCESSORY PRODUCT FEATURESSAFETY DEVICE OPTIONAL BLOWER ASSEMBLY ACCESSORYDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION PROVIDING ADEQUATE VENTILATIONUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building VENTILATION AIRVentilation Air From Outdoors AIR FOR COMBUSTION AND VENTILATIONINSTALLING HOOD INSTALLATIONBlower Accessories, and GA3555 Internal CHECK GAS TYPECONVENTIONAL FIREPLACE INSTALLATION INSTALLATION CLEARANCESIncluded with Mantel Accessory ASSEMBLING AND ATTACHING OPTIONAL BRASS TRIMINSTALLATION INSTALLATIONAccess Figure 10 - Installing Cabinet MantelMantel Clearances for Built-InInstallation BUILT-INFIREPLACE INSTALLATIONINSTALLATION ContinuedInstallation Items Needed INSTALLING GAS PIPING TO FIREPLACE LOCATIONINSTALLATION ContinuedInstallation Items Needed INSTALLATIONContinued 5/16 hex socket wrench or nut-driverPressure Testing Fireplace Gas Connections Pressure Testing gas Supply Piping systemCHECKING GAS CONNECTIONS INSTALLATIONINSTALLING LOGS INSTALLATIONContinued OPERATING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS INSTALLATIONTO TURN OFF GAS TO APPLIANCE MANUAL LIGHTING PROCEDUREOPTIONAL REMOTE OPERATION Shutting Off HeaterGHRCTA Series Operation OPTIONAL BLOWER OPERATIONOPERATING FIREPLACE ContinuedPILOT FLAME PATTERN INSPECTING BURNERSFRONT BURNER FLAME PATTERN MAIN BURNERLOGS CLEANING AND MAINTENANCEOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYRefer to Air for Combustion and Venti Maintenance, pageTROUBLESHOOTING OBSERVED PROBLEMing Gas Connections, page visitTROUBLESHOOTING OBSERVED PROBLEMSPECIFICATIONS WIRING DIAGRAMREPLACEMENT PARTS SERVICE HINTSILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY EFS33NR, VSGF33NR4EFS33PR, VSGF33PR Shown Log Base AssemblyPARTS LIST PARTS LISTPART NUMBER EFS33NRILLUSTRATED PARTS BREAKDOWN FIREPLACE17 EFS33NR,VSGF33NR EFS33PR, VSGF33PRILLUSTRATED PARTS BREAKDOWN FireplacePARTS LIST FIREPLACE EFS33NR, VSGF33NR EFS33PR, VSGF33PRPARTS LIST PART NUMBERBLOWER ACCESSORY GA3700 & GA3700T SERIES ACCESSORIESEQUIPMENT SHUTOFF VALVE - GA5010 DUPLEX OUTLET KIT - GA3555 Not ShownCLEANING KIT - GCK Not Shown BRASS TRIM ACCESSORY - GA7090 Not ShownCORNER HEARTH BASE HARDWOOD HEARTH BASEWALL-MOUNTON/OFF SWITCH - GWMS2 WALL-MOUNTTHERMOSTAT SWITCH - GWMT1GHRCTA SERIES Not ShownOWNERS REGISTRATION FORM 2701 Industrial Drive P.O. Box Bowling Green, KY Postage RequiredPage LIMITED WARRANTY VENT-FREEGAS FIREPLACE KEEP THIS WARRANTYNOT A UPC Model Serial No Date Purchased