Desa EFS33NR Continued, Installation Items Needed, 5/16 hex socket wrench or nut-driver

Page 12
•5/16" hex socket wrench or nut-driver

12

INSTALLATION

Installing Gas Piping to Fireplace Location (Cont.) Connecting Fireplace to Gas Supply

INSTALLATION

Continued

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 18).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves. Never use sealant on flare threads.

Manual background CAUTION: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 18. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

CSA Design-Certified Equipment

Manual background Shutoff Valve With 1/8" NPT Tap*

Natural Gas From Gas Meter

(5" W.C.** to 10.5" W.C. Pressure)

3" Minimum

Propane/LP

From External Regulator

 

 

(11" W.C.** to 14" W.C.

 

Pressure)

Cap Pipe

Tee

Nipple

Joint

Sediment Trap

Figure 18 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, pages 28 through 30.

**Minimum inlet pressure for purpose of input adjustment.

CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROL

Installation Items Needed

5/16" hex socket wrench or nut-driver

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1.Remove fireplace screen. Remove two screws that hold fire- place screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.Remove screws that attach log base assembly to fireplace (see Figure 19). Carefully lift up log base assembly and remove from fireplace (see Figure 19).

Note: If adding the G8000A series brick liner accessory, install it now. Follow instructions in G8000A accessory kit.

Manual background CAUTION: Do not pick up log base assembly by burner. This could damage burner. Only handle base by grates.

3.Route gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one of the access holes.

NOTICE: Most building codes do not permit concealed gas connections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 20, page 13). The flexible gas supply line connection to the equipment shutoff valve should be accessible.

Figure 19 - Removing Log Base Assembly From Fireplace

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundvisitManual backgroundManual background.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

107172

Image 12
Contents OWNER’S OPERATION AND INSTALLATION MANUAL WHAT TO DO IF YOU SMELL GASDo not try to light any appliance UNVENTED VENT-FREEGAS FIREPLACETABLE OF CONTENTS SAFETY INFORMATIONWARNINGS PRODUCT IDENTIFICATION ContinuedSAFETY INFORMATION PRODUCT FEATURES OPTIONAL REMOTE CONTROL ACCESSORYSAFETY DEVICE OPTIONAL BLOWER ASSEMBLY ACCESSORYPROVIDING ADEQUATE VENTILATION DETERMINING FRESH-AIRFLOW FOR HEATER LOCATIONUnusually Tight Construction Confined and Unconfined SpaceVENTILATION AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors AIR FOR COMBUSTION AND VENTILATIONINSTALLATION INSTALLING HOODBlower Accessories, and GA3555 Internal CHECK GAS TYPEINSTALLATION CLEARANCES CONVENTIONAL FIREPLACE INSTALLATIONIncluded with Mantel Accessory ASSEMBLING AND ATTACHING OPTIONAL BRASS TRIMINSTALLATION INSTALLATIONAccess Figure 10 - Installing Cabinet MantelBUILT-INFIREPLACE INSTALLATION Mantel Clearances for Built-InInstallationINSTALLATION ContinuedINSTALLING GAS PIPING TO FIREPLACE LOCATION Installation Items NeededINSTALLATION ContinuedINSTALLATION Installation Items NeededContinued 5/16 hex socket wrench or nut-driverPressure Testing gas Supply Piping system Pressure Testing Fireplace Gas ConnectionsCHECKING GAS CONNECTIONS INSTALLATIONINSTALLING LOGS INSTALLATIONContinued FOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACELIGHTING INSTRUCTIONS INSTALLATIONMANUAL LIGHTING PROCEDURE TO TURN OFF GAS TO APPLIANCEOPTIONAL REMOTE OPERATION Shutting Off HeaterOPTIONAL BLOWER OPERATION GHRCTA Series OperationOPERATING FIREPLACE ContinuedINSPECTING BURNERS PILOT FLAME PATTERNFRONT BURNER FLAME PATTERN MAIN BURNERCLEANING AND MAINTENANCE LOGSTROUBLESHOOTING OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYMaintenance, page Refer to Air for Combustion and VentiTROUBLESHOOTING OBSERVED PROBLEMvisit ing Gas Connections, pageTROUBLESHOOTING OBSERVED PROBLEMWIRING DIAGRAM SPECIFICATIONSREPLACEMENT PARTS SERVICE HINTSLOG BASE ASSEMBLY EFS33NR, VSGF33NR4 ILLUSTRATED PARTS BREAKDOWNEFS33PR, VSGF33PR Shown Log Base AssemblyPARTS LIST PARTS LISTPART NUMBER EFS33NRFIREPLACE17 EFS33NR,VSGF33NR EFS33PR, VSGF33PR ILLUSTRATED PARTS BREAKDOWNILLUSTRATED PARTS BREAKDOWN FireplaceFIREPLACE EFS33NR, VSGF33NR EFS33PR, VSGF33PR PARTS LISTPARTS LIST PART NUMBERACCESSORIES BLOWER ACCESSORY GA3700 & GA3700T SERIESEQUIPMENT SHUTOFF VALVE - GA5010 DUPLEX OUTLET KIT - GA3555 Not ShownBRASS TRIM ACCESSORY - GA7090 Not Shown CLEANING KIT - GCK Not ShownCORNER HEARTH BASE HARDWOOD HEARTH BASEWALL-MOUNTTHERMOSTAT SWITCH - GWMT1 WALL-MOUNTON/OFF SWITCH - GWMS2GHRCTA SERIES Not ShownOWNERS REGISTRATION FORM Postage Required 2701 Industrial Drive P.O. Box Bowling Green, KYPage KEEP THIS WARRANTY LIMITED WARRANTY VENT-FREEGAS FIREPLACENOT A UPC Model Serial No Date Purchased