Desa EFS10TP, EFS26NR, FMH26PR, EFS10TN, FMH26NR Extension Cord, Removing Upper Louver Assembly

Page 14

14

INSTALLATION

Installing Blower Accessory GA3450T in Remote-Ready Models (Cont.) Installing Blower Accessory GA3450T in Thermostat-Controlled Models

INSTALLATION

Continued

3.A licensed electrician must follow the wiring diagram to con- nect incoming electrical supply to fan kit wiring harness (see Figure 19).

4.Plug power cord to the outlet receptacle (not provided) as shown in Figure 20. Wind the extra cable in power cord and and tie it up with the plastic wire strap (see Figure 20). Set the cable bundle between the burner bracket and outer casing, away from the burner.

5.Test to make sure the blower is working properly.

6.Reinstall upper louver assembly (see Figure 15, page 12) and close lower louver.

 

Fan Switch

 

 

 

 

 

 

 

(Auto/Off/On)

 

 

 

 

 

 

 

 

1 Auto

 

 

 

 

 

 

 

Off

2

 

 

 

 

 

 

 

 

 

 

 

3

Blue

 

Thermostat

 

 

 

On

 

 

 

Switch

 

 

 

 

 

 

(N.O.)

110/115

 

 

Red

 

 

 

 

Blue

V.A.C.

 

 

 

 

Blower

 

Black

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

 

 

White

 

 

 

 

 

 

White

 

 

Green

 

 

 

 

 

 

Green

Extension Cord

Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An undersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

INSTALLING OPTIONAL BLOWER ACCESSORY GA3450T IN THERMOSTAT- CONTROLLED MODELS

Removing Upper Louver Assembly

To install the blower accessory, you must first remove the upper louver assembly.

1.Remove 4 screws from upper louver assembly (see Figure 21). Save these screws.

2.Pull upper louver assembly straight out from the cabinet. Be care- ful not to scratch the paint. Set louver assembly and screws aside.

Figure 19 - Wiring Diagram For Blower Accessory Built-In Installation

Blower Bracket

 

Assembly

Wire Harness

Screw

Switch

Power

Outlet Receptacle

Cord

 

(Not Supplied)

 

 

Blower Bracket

Mounting Holes

Brass

Screws

Upper Louver Assembly

Switch

Plate Blue

Black

Red

Plastic

 

 

Wire Strap

Wire Harness

Clamp Connector

 

 

(not included)

 

Lower Louver Door

Figure 20 - Installing Blower Bracket Assembly

Figure 21 - Removing Upper Louver Assembly

For..com

107032-01E

Image 14
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Vent-Free Compact Classic Hearth FireplaceLocal Codes Optional Remote Control AccessoriesProduct Features UnpackingAssembly Assembling FireplaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion and VentilationProviding Adequate Ventilation Ventilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsFireplace Clearances Installation ItemsCheck GAS Type Minimum Clearance to Combustible MaterialsBUILT-IN Fireplace Installation Rough Opening for Installing in WallOptional Mantel Installation Mantel Clearances for Built-In InstallationAssembling Brass Trim Brass trim shipped with mantel Removing Upper Louver Assembly and Branch SupportInstalling Blower Accessory For Built-In Installation Valve cover shield. see FigureRemoving Upper Louver Assembly Extension CordInstalling Blower Assembly Removing Valve Cover ShieldValve Cover Shield Switch PlateScrew Connecting to GAS Supply Attaching Wood Base to Solid FloorConnecting Equipment Shutoff Valve to Heater Control Installation Items NeededPressure Testing gas Supply Piping system Checking GAS ConnectionsInstalling Receiver Optional Wireless HAND-HELD Remote Control AccessoriesPressure Testing Fireplace Gas Connections Installing 9-Volt Battery in Hand-Held Remote Control Unit Optional Wall Mounted Thermostat GWMT1Installing LOG SET and Screen Back View of Thermostat BaseOperating Fireplace Lighting InstructionsTo Turn OFF GAS to Appliance Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting Thermostat Control OperationPropane/LPGasPilot Natural Gas Pilot Thermostat Control Operation Optional Remote OperationGWMT1 Wall Mounted Thermostat Optional Ghrcta Series OperationBurner Flame Pattern GWMS2 Wall Mounted Switch OptionalInspecting Burners Pilot Flame PatternLOG SET Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole CabinetTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause RemedyGas leak. See Warning statement Technical Service SpecificationsService Hints When Gas Pressure Is Too LowParts not Under Warranty Replacement Parts Wiring DiagramParts Under Warranty Remote-Ready Models OnlyIllustrated Parts Breakdown THERMOSTAT-CONTROLLED Models VMH10TPB, VMH10TNBParts List THERMOSTAT-CONTROLLED ModelsREMOTE-READY Models EFS26PR, EFS26NRParts List Accessories WALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT GCKWALL-MOUNT Thermostat Switch GWMT1 Receiver and HAND-HELD Remote Control KIT GhrcFor . .com Owners Registration Form Postage Required 107032-01E Warranty Information Limited Warranty VENT-FREE Compact Classic Hearth Fireplace