Desa EFS26NR, FMH26PR Optional Wireless HAND-HELD Remote Control Accessories, Installing Receiver

Page 20

20

INSTALLATION

Checking Gas Connections (Cont.)

Optional Wireless Hand-Held Remote Control Accessories [Remote-Ready Models Only]

INSTALLATION

Continued

3.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/LP (see Figures 34 or 35). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4.Correct all leaks at once.

OPTIONAL WIRELESS HAND-HELD REMOTE

CONTROL ACCESSORIES

Remote-Ready Models Only

(GHRC Series & GHRCTA Series)

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 33, page 19).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to gas regulator (Thermostat-Controlled Models), or to gas control valve (Remote- Ready Models) (see Figures 34 or 35). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operating Fireplace, pages 23 through 27). Check all other internal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 24 for Thermostat-Controlled Models or page 25 for Remote- Ready Models).

Equipment

Gas Regulator or

Gas Control Valve

Shutoff Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Propane/LP

Supply

Tank

Installing Receiver

1.Remove screws.

2.Disconnect switch wires from the control valve.

3.Remove switch plate (see Figure 36). Discard switch plate after removing. Save the screws.

4.Locate the battery clip mounted on the back of the receiver (see Figure 37).

5.Slide 9-volt battery (not included) through the clip.

6.Attach the terminal wires to the battery (see Figure 37).

7.Connect wires as shown in Figure 38, page 21.

8.Install remote receiver unit onto fireplace base using the two screws removed in step one (see Figure 38, page 21).

Switch Plate

Screw

Red Wire

Black Wire

Figure 36 - Switch Plate and Wiring Harness

Receiver

Figure 34 - Checking Gas Joints (Propane/LP Only)

 

Gas Regulator or

 

Gas Control Valve

 

Equipment

Terminal

Shutoff Valve

Wires

 

 

Battery Clip

Gas Meter

9-Volt Battery

 

 

Figure 37 - Attaching Battery to Receiver

Figure 35 - Checking Gas Joints (Natural Gas Only)

 

For..com

107032-01E

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Vent-Free Compact Classic Hearth FireplaceOptional Remote Control Accessories Product FeaturesLocal Codes UnpackingAssembly Assembling FireplaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion and VentilationProviding Adequate Ventilation Ventilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsInstallation Items Check GAS TypeFireplace Clearances Minimum Clearance to Combustible MaterialsBUILT-IN Fireplace Installation Rough Opening for Installing in WallOptional Mantel Installation Mantel Clearances for Built-In InstallationAssembling Brass Trim Brass trim shipped with mantel Removing Upper Louver Assembly and Branch SupportInstalling Blower Accessory For Built-In Installation Valve cover shield. see FigureRemoving Upper Louver Assembly Extension CordInstalling Blower Assembly Removing Valve Cover ShieldValve Cover Shield Switch PlateScrew Connecting to GAS Supply Attaching Wood Base to Solid FloorConnecting Equipment Shutoff Valve to Heater Control Installation Items NeededPressure Testing gas Supply Piping system Checking GAS ConnectionsInstalling Receiver Optional Wireless HAND-HELD Remote Control AccessoriesPressure Testing Fireplace Gas Connections Installing 9-Volt Battery in Hand-Held Remote Control Unit Optional Wall Mounted Thermostat GWMT1Installing LOG SET and Screen Back View of Thermostat BaseOperating Fireplace Lighting InstructionsManual Lighting Procedure REMOTE-READY Models For Your Safety Read Before LightingTo Turn OFF GAS to Appliance Thermostat Control OperationPropane/LPGasPilot Natural Gas Pilot Optional Remote Operation GWMT1 Wall Mounted Thermostat OptionalThermostat Control Operation Ghrcta Series OperationGWMS2 Wall Mounted Switch Optional Inspecting BurnersBurner Flame Pattern Pilot Flame PatternCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLOG SET CabinetTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause RemedyGas leak. See Warning statement Specifications Service HintsTechnical Service When Gas Pressure Is Too LowReplacement Parts Wiring Diagram Parts Under WarrantyParts not Under Warranty Remote-Ready Models OnlyIllustrated Parts Breakdown THERMOSTAT-CONTROLLED Models VMH10TPB, VMH10TNBParts List THERMOSTAT-CONTROLLED ModelsREMOTE-READY Models EFS26PR, EFS26NRParts List Accessories Cleaning KIT GCK WALL-MOUNT Thermostat Switch GWMT1WALL-MOUNT ON/OFF Switch GWMS2 Receiver and HAND-HELD Remote Control KIT GhrcFor . .com Owners Registration Form Postage Required 107032-01E Warranty Information Limited Warranty VENT-FREE Compact Classic Hearth Fireplace