INSTALLATION

Optional Wireless Hand-Held Remote Control Accessories [Remote-Ready Models Only] (Cont.) Optional Wall Mounted Thermostat - GWMT1 [Remote-Ready Models Only]

21

INSTALLATION

Continued

Remote

Receiver

Red Wire

Black Wire

Wire Harness*

Wires from

Valve

Red Wire

Black Wire

Figure 38 - Installing Remote Receiver

* Wire harness provided in the fireplace hardware pack.

Installing 9-Volt Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery (not included). Place bat- tery into the battery housing.

3.Replace battery cover onto remote control unit.

Terminal

Battery Cover

Remote

Wires

Control Unit

9-Volt

 

Battery

 

Battery

Housing

Figure 39 - Installing Battery in Hand-Held Remote Control Unit (GHRC Series)

Terminal Wires

9-Volt

Remote

Battery

Control Unit

 

Battery

Battery Cover

 

Housing

 

Figure 40 - Installing Battery in Hand-Held Remote Control Unit (GHRCTA Series)

OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

(Remote-Ready Models Only)

WARNING: Read and follow installation instruc- tions. Installation should be done by a qualified installer familiar with low-voltage wiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Connect one terminal of 25 ft. wire to bottom contact of switch (see Figure 41).

2.Connect remaining wire terminal to the “TH” terminal on the control valve. Make sure that wire terminals are in the posi- tions on your unit as pictured in Figure 41. If wires are not “crossed” the thermostat will not work.

3.Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall). IMPORTANT: The wire may be shortened but must not be lengthened.

The thermostat should be mounted 54" above the floor in a loca- tion where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air conditioning ducts.

4.Gently remove the cover of the thermostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.

5.Feed the electrical wires through the rectangular slots on each side of the base (see Figure 42, page 22).

WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.

Switch on Gas

 

 

Fireplace

Control

 

 

 

 

Valve

 

AUTO

 

 

O

 

 

FF

 

 

ON

To Wall

 

One

 

Thermostat

To Wall

terminal

or Switch

Thermostat

of 25 ft.

 

or Switch

wire

 

 

Figure 41 - Connecting Wire Terminals

For morevisit www..com

107032-01E

Image 21
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsVent-Free Compact Classic Hearth Fireplace Product IdentificationProduct Features Optional Remote Control AccessoriesLocal Codes UnpackingAssembling Fireplace AssemblyAIR for Combustion and Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Installation ItemsFireplace Clearances Minimum Clearance to Combustible MaterialsRough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationRemoving Upper Louver Assembly and Branch Support Installing Blower AccessoryAssembling Brass Trim Brass trim shipped with mantel Valve cover shield. see Figure For Built-In InstallationExtension Cord Removing Upper Louver AssemblyRemoving Valve Cover Shield Installing Blower AssemblyValve Cover Shield Switch PlateScrew Attaching Wood Base to Solid Floor Connecting to GAS SupplyInstallation Items Needed Connecting Equipment Shutoff Valve to Heater ControlChecking GAS Connections Pressure Testing gas Supply Piping systemOptional Wireless HAND-HELD Remote Control Accessories Pressure Testing Fireplace Gas ConnectionsInstalling Receiver Optional Wall Mounted Thermostat GWMT1 Installing 9-Volt Battery in Hand-Held Remote Control UnitBack View of Thermostat Base Installing LOG SET and ScreenLighting Instructions Operating FireplaceREMOTE-READY Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Turn OFF GAS to Appliance Thermostat Control OperationPropane/LPGasPilot Natural Gas Pilot GWMT1 Wall Mounted Thermostat Optional Optional Remote OperationThermostat Control Operation Ghrcta Series OperationInspecting Burners GWMS2 Wall Mounted Switch OptionalBurner Flame Pattern Pilot Flame PatternCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLOG SET CabinetObserved Problem Possible Cause Remedy TroubleshootingRemedy Observed Problem Possible CauseGas leak. See Warning statement Service Hints SpecificationsTechnical Service When Gas Pressure Is Too LowParts Under Warranty Replacement Parts Wiring DiagramParts not Under Warranty Remote-Ready Models OnlyTHERMOSTAT-CONTROLLED Models VMH10TPB, VMH10TNB Illustrated Parts BreakdownTHERMOSTAT-CONTROLLED Models Parts ListEFS26PR, EFS26NR REMOTE-READY ModelsParts List Accessories WALL-MOUNT Thermostat Switch GWMT1 Cleaning KIT GCKWALL-MOUNT ON/OFF Switch GWMS2 Receiver and HAND-HELD Remote Control KIT GhrcFor . .com Owners Registration Form Postage Required 107032-01E Limited Warranty VENT-FREE Compact Classic Hearth Fireplace Warranty Information