Desa EFS10TN Specifications, Service Hints, Technical Service, When Gas Pressure Is Too Low

Page 32

32

SPECIFICATIONS

SERVICE HINTS TECHNICAL SERVICE

SPECIFICATIONS

 

Thermostat Models:

Thermostat Models:

Remote-Ready Models:

Remote-Ready Models:

 

VMH10TPB, EFS10TP

VMH10TNB, EFS10TN

VMH26PRA, EFS26PR,

VMH26NRA, EFS26NR,

 

 

 

FMH26PR

FMH26NR

Btu/Hr

10,000

10,000

15,000/26,000

15,000/26,000

Type Gas

Propane/LP Gas Only

Natural Gas Only

Propane/LP Gas Only

Natural Gas Only

Ignition

Piezo

Piezo

Piezo

Piezo

Manifold Pressure

8.5" W.C.

3" W.C.

8" W.C.

3.5" W.C.

Inlet Gas Pressure

 

 

 

 

(in. of water)

 

 

 

 

Maximum

14"

10.5"

14"

10.5"

Minimum*

11"

5"

11"

5"

Dimensions, inches (HxWxD)

 

 

 

Fireplace

25 7/8 x 26 13/16 x 9 3/8

25 7/8 x 26 13/16 x 9 3/8

25 7/8 x 26 13/16 x 9 3/8

25 7/8 x 26 13/16 x 9 3/8

(including hood

 

 

 

 

and screws)

 

 

 

 

Carton

32 5/8 x 27 13/16 x 11 5/8

32 5/8 x 27 13/16 x 11 5/8

32 5/8 x 27 13/16 x 11 5/8

32 5/8 x 27 13/16 x 11 5/8

Weight, pounds

 

 

 

 

Fireplace

44 1/2 lbs.

44 1/2 lbs.

44 1/2 lbs.

44 1/2 lbs.

Shipping

48 lbs.

48 lbs.

48 lbs.

48 lbs.

* For purpose of input adjustment

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

for propane/LP units, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA International’s technical services web site at www.desatech.com.

For..com

107032-01E

Image 32
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Vent-Free Compact Classic Hearth FireplaceOptional Remote Control Accessories Product FeaturesLocal Codes UnpackingAssembly Assembling FireplaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion and VentilationProviding Adequate Ventilation Ventilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsInstallation Items Check GAS TypeFireplace Clearances Minimum Clearance to Combustible MaterialsBUILT-IN Fireplace Installation Rough Opening for Installing in WallOptional Mantel Installation Mantel Clearances for Built-In InstallationAssembling Brass Trim Brass trim shipped with mantel Removing Upper Louver Assembly and Branch SupportInstalling Blower Accessory For Built-In Installation Valve cover shield. see FigureRemoving Upper Louver Assembly Extension CordInstalling Blower Assembly Removing Valve Cover ShieldValve Cover Shield Switch PlateScrew Connecting to GAS Supply Attaching Wood Base to Solid FloorConnecting Equipment Shutoff Valve to Heater Control Installation Items NeededPressure Testing gas Supply Piping system Checking GAS ConnectionsInstalling Receiver Optional Wireless HAND-HELD Remote Control AccessoriesPressure Testing Fireplace Gas Connections Installing 9-Volt Battery in Hand-Held Remote Control Unit Optional Wall Mounted Thermostat GWMT1Installing LOG SET and Screen Back View of Thermostat BaseOperating Fireplace Lighting InstructionsManual Lighting Procedure REMOTE-READY Models For Your Safety Read Before LightingTo Turn OFF GAS to Appliance Thermostat Control OperationPropane/LPGasPilot Natural Gas Pilot Optional Remote Operation GWMT1 Wall Mounted Thermostat OptionalThermostat Control Operation Ghrcta Series OperationGWMS2 Wall Mounted Switch Optional Inspecting BurnersBurner Flame Pattern Pilot Flame PatternCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLOG SET CabinetTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause RemedyGas leak. See Warning statement Specifications Service HintsTechnical Service When Gas Pressure Is Too LowReplacement Parts Wiring Diagram Parts Under WarrantyParts not Under Warranty Remote-Ready Models OnlyIllustrated Parts Breakdown THERMOSTAT-CONTROLLED Models VMH10TPB, VMH10TNBParts List THERMOSTAT-CONTROLLED ModelsREMOTE-READY Models EFS26PR, EFS26NRParts List Accessories Cleaning KIT GCK WALL-MOUNT Thermostat Switch GWMT1WALL-MOUNT ON/OFF Switch GWMS2 Receiver and HAND-HELD Remote Control KIT GhrcFor . .com Owners Registration Form Postage Required 107032-01E Warranty Information Limited Warranty VENT-FREE Compact Classic Hearth Fireplace