INSTALLATION
Installing Blower Accessory GA3450T in
13
INSTALLATION
Continued
3. | Note the wire locations on back of AUTO/OFF/ON switch. |
| The terminals on back of switch are numbered 1, 2, and 3. |
| Carefully remove red wire from terminal 3 and blue wire from |
| terminal 1. Black wire can remain on middle terminal 2 (see |
| Figure 16). |
4. | Carefully disconnect green and white wires at their insulated |
| connectors (see Figure 17). |
5. | In top of the fireplace cabinet, locate the four mounting holes |
| on the outer casing. Align these four holes with those on the |
| blower bracket assembly. Attach blower bracket assembly to |
| the outer casing with 4 #10 screws provided (see Figure 16). |
6. | Route the wire harness through the hole in left side of baffle. |
| Pull wire harness through lower opening on the side of the |
9.Install the switch plate on the valve cover shield with 2 #10 screws provided (see Figure 18). Route power cord out of the cabinet by inserting it through the bushing on the outer casing (see Figure 16). Plug fan kit into
Fan Switch
(Auto/Off/On)
1Auto
| valve cover shield. (see Figure 16). |
7. | Insert the 4 wire harnesses into one of the round holes in the rear |
| of the valve cover shield and through the rectangular hole in the |
| front of shield (see Figure 16). |
8. | Reconnect red wire to switch position 3. Reconnect blue wire |
| to switch position 1. Reconnect green and white wires. |
|
| Off | 2 |
|
|
| 3 |
|
|
| On |
110/115 | Red | ||
| V.A.C. |
| |
|
| Black |
|
|
|
| |
|
| White |
|
|
| Green |
|
Blue Thermostat
Switch
(N.O.)
Blue
Blower
Motor
Red
White
Green
Blower Bracket | Wire | Wiring Routing | ||
Harness | Hole in Baffle | |||
Assembly | ||||
|
|
| ||
Screw |
| Baffle | Blower | |
|
|
| Mounting |
Holes
Switch | Power Cord Snap |
| |
| Bushing |
3 |
|
2 |
|
1 |
|
Switch
Plate Blue
Black Red
Wire
Harness Valve
Cover
Shield
Lower Louver Door
Figure 16 - Installing Blower Bracket Assembly
Figure 17 - Wiring Diagram For Blower Accessory Standard Installation
Valve Cover
Shield
Switch
Plate
Screw
Figure 18 - Installing Switch Plate to Valve Cover Shield
For Built-In Installation
WARNING: A licensed electrician must connect the wiring harness to electrical supply following all local codes. Electrician must provide a clamp on the box cover to secure the wiring. Wiring should be routed through the bushing in the hole on the outer casing of fireplace.
1.Install a snap bushing found in hardware kit into one of the holes on rear of valve cover shield. The other hole is for a strain relief clamp (not supplied) to secure incoming electrical supply.
2.Follow steps 2 through 6 in Installing Blower Accessory, pages 12 and 13.
For morevisit www..com