Desa CD36TN-M installation manual Continued, Electrical Supply Connection, Number, Description

Page 18
Number

Venting Installation

instructions

 

Continued

Number

Description

CVVK-58

Ceiling Vertical Vent Kit

 

(Includes: 30° Offset Return, 7"-12"

 

Adjustable Pipe, Flue Restrictor,

 

Vertical High Wind Termination,

 

3' Pipe, 4' Pipe, Firestop Plate,

 

Firestop Thimble, Storm Collar,

 

Roof Flashing [0/12 - 6/12], 38

 

Screws)

CHVK-58

Corner Horizontal Vent Kit,

 

(Includes 90° Elbow, 7"-12"

 

Adjustable Pipe, Wall Firestop,

 

Horizontal Square Termination,

 

6" Pipe, 18 Screws)

HHTK-58

High Wind Round Horizontal

 

Termination Kit (Includes Round

 

Termination, Wall Firestop, 45°

 

Elbow)

HHT-58

High Wind Round Horizontal

 

Termination Kit, Galv.

HTS-58

Horizontal Square Termination,

 

Galv. HTKS-58 Horizontal Square

 

Termination Kit (Includes: Square

 

Termination, Wall Firestop, 45°

 

Elbow)

VT-58

Vertical Round Termination, Galv.

SC-58

Storm Collar, Galv.

WF-58

Wall Firestop, Galv.

RF-58-6

Roof Flashing - 0 to 6/12 Pitch,

 

Galv.

RF-58-12

Roof Flashing - 6/12 to 12/12

 

Pitch, Galv.

VR-58

Vertical Restrictor, Galv.

S-58

Vinyl Siding Standoff, Galv.

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

FP-58

Firestop Plate

SF-58

Stucco Flashing -

 

For use with HTS-58

RF-58

Flat Roof Flashing

Fireplace

Installation

ELECTRICAL SUPPLY CONNECTION

Description CAUTION: Disconnect the electrical power to the supply circuit before attempting to con- nect or service this appliance.

ELECTRICAL SUPPLY CONNECTION WARNING: This appliance, when installed must be electri- cally grounded in accordance with local code or in the ab- sence of local code, with the current National Electric Code, ANSI/NFPA 70, or the Canadian Electric Code, CSA C22.1.

A prewired junction box receptacle with strain relief is provided on the right side of the cabinet for hard wiring the unit to a 15 Amp, 120VAC, 60Hz grounded branch circuit. If the installation demands that the electrical supply be connected from the left side, the entire receptacle box can be relocated to the left side by following these instructions:

Note: If you do not need to relocate the junction box, to connect the electric supply follow steps 8 through 11 only:

1.Remove 2 screws and outer cover with strain relief bushing on right side of cabinet (see Figure 26).

2.Remove inner retaining screw on junction box mounting tab.

3.Slide junction box up until screw mounting tab is lined up to notch in outer cabinet.

J-Box Cover

J-Box

with Strain

Cover

Relief

J-Box Cover with

 

 

Strain Relief

Romex Cable

Figure 26 - Relocating Junction Box J-Box with

Receptacle Receptacle and Electrical Supply

Manual backgroundScrew/Tab Manual background Retainer

Figure 26 - Relocating Junction Box

Receptacle and Electrical Supply

Connection

18

www.desatech.com

118531-01A

Image 18
Contents WHAT TO DO IF YOU SMELL GAS Table of Contents Safety Information Safety information Product IdentificationContinued Local Codes Product FeaturesPre-Installation Preparation Location and space requirementsPackaging and Removal Figure 3 - Fireplace Bottom DimensionsContinued ClearancesContinued InstallationFigure 6 - Unit Dimensions Figure 5 - Framing Clearances for CornerContinued MANTEL CLEARANCESInside Corner D E B LFigure 9 - Minimum Clearances for Termination Cap Outside CornerVenting Installation Instructions Continued Venting Installation instructionsINSTALLATION PLANNING Figure 10 - Vent Pipe ConnectionsInner Wall Firestop Figure 12 - Installing Siding StandoffFigure 13 - Installing Outer Wall Firestop Standoff Vent Cap Apply Mastic to All Four SidesConfiguration with Vertical Rise and One 90 Elbow Configuration For Corner InstallationUsing One 90 Elbow Clearance at Ground Floor InstallationHORIZONTAL VENT INSTALLATIONS ContinuedFigure 20 - Installing Firestop Installation for vertical terminationFlat Ceiling Installation ContinuedFigure 21 - Installing Thimble with Firestop Thimble InstallationVertical Termination Configurations for Top Vent ContinuedContinued parts list for venting kits and componentsConfiguration Using Two 90 Elbows Figure 23 - Vertical VentingNumber ContinuedELECTRICAL SUPPLY CONNECTION DescriptionFigure 28 - Attaching Speed Control to Installing optional blower accessoriesFigure 27 - Blower Model BK Firebox Millivolt ModelsModel BKT Installation ContinuedFigure 30 - Blower Model BKT Figure 32 - Millivolt Ignition Wiring Diagram Wiring DiagramsFigure 31 - Blower Wiring Diagram for ContinuedInstalling Remote Receiver Installing optional wall Mount Switch - gwmS2Figure 33 - Connecting Wall Switch to Figure 34 - Attaching Alkaline Battery toContinued Installing Gas Piping to Fireplace LocationInstallation Items Needed Check Gas TypeFigure 39 - Connecting Flexible Gas Line CONNECTING FIREPLACE TO GAS SUPPLYInstallation Items Needed Pressure Testing Gas Supply Piping SystemFigure 42 - Checking Gas Joints for Removing/Replacing Glass DoorFigure 40 - Equipment Shutoff Valve Natural Gas FireplaceContinued Removing Lower Louver Access PanelFigure 43 - Removing Lower Louver Access Panel Removing Top Louver Trim PanelContinued Installing LOGS, lava rock and glowing embersFigure 46 - Installing Logs Figure 45 - Removing/Replacing Glass Doorlighting instructions for your safety Read before lightingOperating Fireplace TO TURN OFF GAS TO APPLIANCEContinued MANUAL LIGHTING PROCEDUREFigure 49 - Setting the Selector Switch optional Hand-Held REMOTE OPERATIONAuto Shutoff Feature operating optional blower accessorySafety Features Remote Control Unit HRC200Figure 52 - Pilot Assembly Millivolt pilot assemblysee Troubleshooting, page see Troubleshooting, pageContinued Figure 54 - Removing Logs and Burner AssemblyFigure 56 - Adjusting Air Shutter Pilot Orifice ConversionGas Control Conversion Cleaning and MaintenanceConversion Instructions GLASS DOORpilot and burners CAUTION: Do not vacuum if pieces are hotContinued logsPOSSIBLE CAUSE TroubleshootingOBSERVED PROBLEM REMEDYContinued TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEWARNING If you smell gas Shut off gas supply Parts Not Under Warranty OBSERVED PROBLEMParts Under Warranty ContinuedMANUAL BLOWER KIT - BK WALL MOUNTED ON/OFF SWITCH GWMS2 Not ShownWhen Gas Pressure Is Too Low THERMOSTATICALLY - CONTROLLED BLOWER KIT - BKTFireplace Assembly for Model CD36TN-M Illustrated Parts BreakdownPARTS LIST FIREPLACE ASSEMBLY FOR MODEL CD36TN-MBURNER ASSEMBLY FOR MODEL CD36TN-M Illustrated parts breakdownBURNER ASSEMBLY FOR MODEL CD36TN-M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16Warranty Information KEEP THIS WARRANTYLIMITED WARRANTY DIRECT-VENTFIREPLACE