Continued

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob pro- vided on shaft.

7.Turn on power to duplex outlet if previously turned off per the warningon page 19.

8.Plug in blower power cord.

a.If your firebox is installed as a free- standing unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox.

b.If your firebox installation is recessed and/or prewired, plug the power cord into the duplex outlet provided. Refer to your firebox owner’s manual for instructions on wiring the duplex outlet.

Figure 30 - Blower Model BKT CAUTION: Never touch the blower wheel while in operation.

9.Check to make sure that the power cord is com- pletely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by turning knob fully counterclock- wise before continuing.

10.Peel off the backing paper and stick the sup- plied wiring diagram decal on the firebox bot- tom approximately 12" in front of the blower (see Figure 29).

Model BKT Installation

Note: When installing the BKT thermostati- cally-controlled blower, you must first secure the thermal switch bracket to the blower if it has not already been factory installed.

1.Place the green ground wire with ring terminal between the bottom hole on the thermal switch bracket and the top ear hole on the blower as- sembly. Insert the phillips screw into all three pieces and tighten securely (see Figure 30).

2.Connect wire harness and power cord ter- minals. Connect the blue jumper wire to the blower motor terminal and the right side ter- minal of the thermal switch. Connect the black wire to the left side of the thermal switch and the white wire to the other remaining blower motor terminal.

Note: The power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connections. DO NOT trim excessive length away. Just enable enough to make all connections securely.

Power Cord

 

Thermal

White Wire Blue Wire

 

Magnetic

Switch

 

 

Strips

Bracket

 

 

 

Black

 

Air Flow

 

Direction

Wire

 

 

Phillips

 

Ring Terminal on

Screw Thermal

Green Wire

Switch

 

Air Flow

Direction

Wiring Diagram Decal

6" in Front of Blower

Figure 29 - Location of Wiring Diagram Decal (Model May Vary From Illustration)

Thermodisc

 

Route BKT Blower

Blower

Magnets

Through This Area

Location

Side View Firebox Bottom

Figure 30 - Blower Model BKT

20

www.desatech.com

118531-01A

Image 20
Contents WHAT TO DO IF YOU SMELL GAS Table of Contents Safety Information Continued Safety informationProduct Identification Product Features Pre-Installation PreparationLocal Codes Location and space requirementsFigure 3 - Fireplace Bottom Dimensions ContinuedPackaging and Removal ClearancesInstallation Figure 6 - Unit DimensionsContinued Figure 5 - Framing Clearances for CornerContinued MANTEL CLEARANCESD E B L Figure 9 - Minimum Clearances for Termination CapInside Corner Outside CornerVenting Installation Instructions Venting Installation instructions INSTALLATION PLANNINGContinued Figure 10 - Vent Pipe ConnectionsFigure 12 - Installing Siding Standoff Figure 13 - Installing Outer Wall FirestopInner Wall Firestop Standoff Vent Cap Apply Mastic to All Four SidesConfiguration For Corner Installation Using One 90 ElbowConfiguration with Vertical Rise and One 90 Elbow Clearance at Ground Floor InstallationHORIZONTAL VENT INSTALLATIONS ContinuedInstallation for vertical termination Flat Ceiling InstallationFigure 20 - Installing Firestop ContinuedThimble Installation Vertical Termination Configurations for Top VentFigure 21 - Installing Thimble with Firestop Continuedparts list for venting kits and components Configuration Using Two 90 ElbowsContinued Figure 23 - Vertical VentingContinued ELECTRICAL SUPPLY CONNECTIONNumber DescriptionInstalling optional blower accessories Figure 27 - Blower Model BKFigure 28 - Attaching Speed Control to Firebox Millivolt ModelsFigure 30 - Blower Model BKT Model BKT InstallationContinued Wiring Diagrams Figure 31 - Blower Wiring Diagram forFigure 32 - Millivolt Ignition Wiring Diagram ContinuedInstalling optional wall Mount Switch - gwmS2 Figure 33 - Connecting Wall Switch toInstalling Remote Receiver Figure 34 - Attaching Alkaline Battery toInstalling Gas Piping to Fireplace Location Installation Items NeededContinued Check Gas TypeCONNECTING FIREPLACE TO GAS SUPPLY Installation Items NeededFigure 39 - Connecting Flexible Gas Line Pressure Testing Gas Supply Piping SystemRemoving/Replacing Glass Door Figure 40 - Equipment Shutoff ValveFigure 42 - Checking Gas Joints for Natural Gas FireplaceRemoving Lower Louver Access Panel Figure 43 - Removing Lower Louver Access PanelContinued Removing Top Louver Trim PanelInstalling LOGS, lava rock and glowing embers Figure 46 - Installing LogsContinued Figure 45 - Removing/Replacing Glass Doorfor your safety Read before lighting Operating Fireplacelighting instructions TO TURN OFF GAS TO APPLIANCEMANUAL LIGHTING PROCEDURE Figure 49 - Setting the Selector SwitchContinued optional Hand-Held REMOTE OPERATIONoperating optional blower accessory Safety FeaturesAuto Shutoff Feature Remote Control Unit HRC200pilot assembly see Troubleshooting, pageFigure 52 - Pilot Assembly Millivolt see Troubleshooting, pageFigure 54 - Removing Logs and Burner Assembly Figure 56 - Adjusting Air ShutterContinued Pilot Orifice ConversionCleaning and Maintenance Conversion InstructionsGas Control Conversion GLASS DOORCAUTION: Do not vacuum if pieces are hot Continuedpilot and burners logsTroubleshooting OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYTROUBLESHOOTING OBSERVED PROBLEMContinued POSSIBLE CAUSEWARNING If you smell gas Shut off gas supply OBSERVED PROBLEM Parts Under WarrantyParts Not Under Warranty ContinuedWALL MOUNTED ON/OFF SWITCH GWMS2 Not Shown When Gas Pressure Is Too LowMANUAL BLOWER KIT - BK THERMOSTATICALLY - CONTROLLED BLOWER KIT - BKTFireplace Assembly for Model CD36TN-M Illustrated Parts BreakdownPARTS LIST FIREPLACE ASSEMBLY FOR MODEL CD36TN-MBURNER ASSEMBLY FOR MODEL CD36TN-M Illustrated parts breakdownBURNER ASSEMBLY FOR MODEL CD36TN-M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16LIMITED WARRANTY DIRECT-VENTFIREPLACE Warranty InformationKEEP THIS WARRANTY