Desa CD36TN-M Operating Fireplace, for your safety Read before lighting, lighting instructions

Page 28
Operating Fireplace

Operating Fireplace

for your safety

Read before lighting

for your safety WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A. This appliance has a pilot which must be

lighted by hand. When lighting the pilot,

follow these instructions exactly.

B. BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next

to the floor because some gas is heavier than

air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier

6.The pilot is located by the main burner and should not require accessing for lighting.

7.Turn gas control knob counterclockwise to

PILOT.

8.Push in gas control knob all the way and hold. Immediately light the pilot by repeatedly de- pressing the piezo spark ignitor until a flame appears. Continue to hold for about 1 minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to OFF and call your service technician or gas supplier.

9.Turn on all electric power to fireplace.

10.Turn gas control knob counterclockwise to “ON”.

11.This valve is equipped with a HI/LO fea- ture. Set fireplace input as desired.

12.Close lower louver panel.

from a neighbor's phone. Follow the gas

supplier's instructions.

C. Use only your hand to push in or turn the

gas control knob. Never use tools. If the knob

will not push in or turn by hand, don't try to

repair it, call a qualified service technician.

Force or attempted repair may result in a

fire or explosion.

D. Do not use this appliance if any part has

Gas Control Variable

Knob

Control Knob

 

OT

 

IL

 

P

 

IL

P OT

F

HI

F

O

O

 

N

 

LO

IN

OUT

Piezo Ignitor

TPTH TP TH

been under water. Immediately call a

qualified service technician to inspect the

appliance and to replace any part of the

control system and any gas control which

has been under water.

lighting

instructions

1.STOP! Read the safety information above.

2.Open lower louver panel.

3.Turn off all electric power to the fire- place.

4.Push in gas control knob slightly and turn clockwise to OFF (see Figure 48).

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas go to the next step.

Figure 48 - Control Valve

TO TURN OFF GAS

TO APPLIANCE

1.Open lower louver panel.

2.Set the wall switch to the OFF position or the HRC selector switch (when equipped) to prevent draining the battery.

3.Turn off all electric power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn clockwise to OFF.

5.Close lower louver panel.

Shutting Off Burners Only (pilot stays lit) You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn gas control knob clockwise to the PILOT position.

2.Set the wall switch to the OFF position or the HRC selector switch (when equipped) to prevent draining the battery.

28

www.desatech.com

118531-01A

Image 28
Contents WHAT TO DO IF YOU SMELL GAS Table of Contents Safety Information Product Identification Safety informationContinued Product Features Pre-Installation PreparationLocal Codes Location and space requirementsFigure 3 - Fireplace Bottom Dimensions ContinuedPackaging and Removal ClearancesInstallation Figure 6 - Unit DimensionsContinued Figure 5 - Framing Clearances for CornerContinued MANTEL CLEARANCESD E B L Figure 9 - Minimum Clearances for Termination CapInside Corner Outside CornerVenting Installation Instructions Venting Installation instructions INSTALLATION PLANNINGContinued Figure 10 - Vent Pipe ConnectionsFigure 12 - Installing Siding Standoff Figure 13 - Installing Outer Wall FirestopInner Wall Firestop Standoff Vent Cap Apply Mastic to All Four SidesConfiguration For Corner Installation Using One 90 ElbowConfiguration with Vertical Rise and One 90 Elbow Clearance at Ground Floor InstallationHORIZONTAL VENT INSTALLATIONS ContinuedInstallation for vertical termination Flat Ceiling InstallationFigure 20 - Installing Firestop ContinuedThimble Installation Vertical Termination Configurations for Top VentFigure 21 - Installing Thimble with Firestop Continuedparts list for venting kits and components Configuration Using Two 90 ElbowsContinued Figure 23 - Vertical VentingContinued ELECTRICAL SUPPLY CONNECTIONNumber DescriptionInstalling optional blower accessories Figure 27 - Blower Model BKFigure 28 - Attaching Speed Control to Firebox Millivolt ModelsContinued Model BKT InstallationFigure 30 - Blower Model BKT Wiring Diagrams Figure 31 - Blower Wiring Diagram forFigure 32 - Millivolt Ignition Wiring Diagram ContinuedInstalling optional wall Mount Switch - gwmS2 Figure 33 - Connecting Wall Switch toInstalling Remote Receiver Figure 34 - Attaching Alkaline Battery toInstalling Gas Piping to Fireplace Location Installation Items NeededContinued Check Gas TypeCONNECTING FIREPLACE TO GAS SUPPLY Installation Items NeededFigure 39 - Connecting Flexible Gas Line Pressure Testing Gas Supply Piping SystemRemoving/Replacing Glass Door Figure 40 - Equipment Shutoff ValveFigure 42 - Checking Gas Joints for Natural Gas FireplaceRemoving Lower Louver Access Panel Figure 43 - Removing Lower Louver Access PanelContinued Removing Top Louver Trim PanelInstalling LOGS, lava rock and glowing embers Figure 46 - Installing LogsContinued Figure 45 - Removing/Replacing Glass Doorfor your safety Read before lighting Operating Fireplacelighting instructions TO TURN OFF GAS TO APPLIANCEMANUAL LIGHTING PROCEDURE Figure 49 - Setting the Selector SwitchContinued optional Hand-Held REMOTE OPERATIONoperating optional blower accessory Safety FeaturesAuto Shutoff Feature Remote Control Unit HRC200pilot assembly see Troubleshooting, pageFigure 52 - Pilot Assembly Millivolt see Troubleshooting, pageFigure 54 - Removing Logs and Burner Assembly Figure 56 - Adjusting Air ShutterContinued Pilot Orifice ConversionCleaning and Maintenance Conversion InstructionsGas Control Conversion GLASS DOORCAUTION: Do not vacuum if pieces are hot Continuedpilot and burners logsTroubleshooting OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYTROUBLESHOOTING OBSERVED PROBLEMContinued POSSIBLE CAUSEWARNING If you smell gas Shut off gas supply OBSERVED PROBLEM Parts Under WarrantyParts Not Under Warranty ContinuedWALL MOUNTED ON/OFF SWITCH GWMS2 Not Shown When Gas Pressure Is Too LowMANUAL BLOWER KIT - BK THERMOSTATICALLY - CONTROLLED BLOWER KIT - BKTFireplace Assembly for Model CD36TN-M Illustrated Parts BreakdownPARTS LIST FIREPLACE ASSEMBLY FOR MODEL CD36TN-MBURNER ASSEMBLY FOR MODEL CD36TN-M Illustrated parts breakdownBURNER ASSEMBLY FOR MODEL CD36TN-M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16KEEP THIS WARRANTY Warranty InformationLIMITED WARRANTY DIRECT-VENTFIREPLACE