Country Flame FP37, FP42, Fireplace FP33 manual 4Chapter, Fireplace Furnace Maintenance Requirements

Page 40

4Chapter

FIREPLACE FURNACE MAINTENANCE REQUIREMENTS

SYSTEM

The majority of fires and accidents occurring with solid fuel-wood burning appliances are a result of improper maintenance of a fireplace. Visual inspections of the fireplace furnace, the chimney, the chimney connectors and the chimney cap on a semi-annual basis will reduce the probability of a fire or accident.

A visual inspection should be made on monthly basis. All dampers and moving parts should move freely without sticking. All metal parts should be checked for corrosion or air leaks. Any weak or damaged metal should be replaced with equal or greater thickness metal. The inside of the chimney should be checked regularly for the buildup of any creosote. If the inside of the chimney has a flat black appearance it should be considered relatively clean. If the inside of the chimney has a shiny black appearance this would indicate that creosote is building up and the chimney needs to be properly cleaned.

All factory-built chimney and chimney connectors should be professionally cleaned at least once each year. Certified chimney sweeps advertise in the local yellow pages and should be contacted for professional cleaning services. The efficiency of a fireplace is directly impacted by the maintenance performed. Failure to keep the fireplace clean will limit the fireplace furnace heat output.

BLOWERS

The two (2) blower assemblies each have an electrical motor that has one oil hole. These motors will require annual lubrication. High temperature blower motor systems are lubricated at the factory and should require no further lubrication during the first year; however, at higher inlet temperatures and with time, increased bearing life can be achieved by annually lubricating the motors with 10 to 20 drops of Anderol Number 465 high temperature synthetic lubricant. DO NOT USE petroleum-based oil, as bearing failure will result. Lubrication can be accomplished by removing the each grille from the blower box face. WARNING: Electrical power must be removed from the fireplace furnace to avoid shock hazard when lubricating the fans. Performing this simple annual maintenance on motors will ensure smoother, quieter, and longer life from each of these electrical devices.

OVER FIRING

Important: If any part of the fireplace furnace metal frame glows red, it is being over fired. Over firing is dangerous. It not only reduces the life expectancy of the product, it can also overheat the immediate area and increases the potential for creating dangerous conditions that can ignite surrounding areas. Close the draft control to reduce a fire by limiting the amount of airflow through the firebox.

In the event of a power failure the blower motors will not operate. This will limit the amount of heat that is being distributed through the duct system and will cause the fireplace furnace to burn hotter. In case of a power outage, it is suggested that a medium to small fire be maintained in the firebox. DO NOT OVERFIRE. Do not expect to heat the house to a desired temperature during a power outage.

Version 7.1

29

 

Image 40
Contents Installation,Operation MaintenanceManual Installation, Operation & Maintenance Manual Table of Contents Version Iii Please keep a copy for your personal records Date Purchased Model No# Serial No# Installed By Trained By Foreword Safety Notes Version Viii Fireplace Furnace Safety Label PP-741 Chimney SizeIntroduction Country Flame Technologies1Chapter WHAT’S Included with Your Smart FIREPLACE?Fireplace Furnace Specifications ModelFireplace Dimensions Steps to Install a Smart Fireplace Footings and FoundationsSingle Opening Fireplace Systems Outside Wall PAD Installation Concrete PAD & Hearth ExtensionsInside Wall PAD Installation Fireplace Position on the Concrete PAD Fireplace Wall & Chimney ConstructionChimney Flue Installation Masonry Wall InstallationTypical HT Adapter optional Installation Model No Angle Iron Duct Size Flue Size Height Depth Masonry Chimney Installation Blower Installations Blower InstallationAIR Intake Grille Installation Heat Discharge Boot Completion of Masonry Brick Front Flue Damper Control Installation Damper PartsDamper Door Removal Damper Door Control Electrical System Thermal Snap Disk LocationElectrical System Version 2Chapter Ducting OptionsDucting Systems Examples Ducting Systems Examples Fireplace Furnace Operational Requirements Internal Thermostat Wood Fireplace Furnace Maintenance Requirements 4ChapterOutside Combustion AIR Troubleshooting Guide Problem Cause SolutionCombustion. Open your draft controls for up Replacement Parts Replacement Parts cont’d Part Drawings Ceramic Snap DISK, PP-91 THERMOSTAT, PP-563 Insulation for TOP, SIDES, FRONT, and BACK, PP-35 ASH Dump COVER, FP-0000-916 Yoke Bracket ASSEMBLY, FP-0000-923 Damper ROD ASSEMBLY, FP-0000-920 FP-33 & FP-37 Flue to HT Chimney ADAPTER, F-218 Grille BACK, FP-0000-33 Grille FRONT, FP-0000-32 AIR Intake GRILLE, PP-560 Adjustable Heat Discharge Boot OPTIONAL, FP-0000-925 LOG Grate optional, LG-900 Company Label Grate Warning Label Country Flame Technologies Required Warranty Information

Fireplace FP33, FP42, FP37 specifications

The Country Flame FP37, FP33, and FP42 fireplaces represent the pinnacle of modern heating technology, with each model expertly designed to meet the diverse demands of homeowners. These fireplaces offer not only warmth but also an aesthetic flair that enhances any living space.

The FP37 is renowned for its substantial heat output, making it an ideal option for larger areas. With a heating capacity of up to 2,800 square feet, it incorporates advanced combustion technology that ensures efficient fuel consumption while maximizing heat production. The innovative air wash system keeps the glass pane clear, providing a spectacular view of the dancing flames. Its multi-fuel capability allows users to burn wood, coal, or pellets, providing flexibility and convenience based on individual preferences.

In contrast, the FP33 is designed for smaller spaces without sacrificing performance. This compact model is capable of heating areas up to 2,000 square feet. Its efficient design promotes quick and easy installation, making it a favorite among homeowners looking for an effective heating solution with a smaller footprint. The FP33 features an adjustable firebox, enabling users to control the intensity of the flames and the heat output according to their needs, ensuring a cozy environment throughout the chilly months.

Meanwhile, the FP42 is a robust option for those seeking a powerful heating source. With a capacity to heat spaces exceeding 3,000 square feet, it features a larger firebox allowing for longer burn times and reduced refueling frequency. Like its counterparts, the FP42 employs a state-of-the-art catalytic converter that enhances burn efficiency and reduces harmful emissions, making it an environmentally responsible choice for heating.

All three models prioritize user-friendliness, with easy-to-use controls and straightforward maintenance. Their durable construction, designed to withstand high temperatures, ensures longevity and reliability. Additionally, all Country Flame fireplaces are backed by an industry-leading warranty, providing peace of mind for owners.

With sleek designs and a variety of options to suit different aesthetics, Country Flame FP37, FP33, and FP42 fireplaces truly embody the blend of functionality and beauty. Whether for a cozy living room or a spacious family area, these fireplaces guarantee a warm and inviting atmosphere, making them an exquisite addition to any home. Choosing any of these models means investing in quality warmth and unmatched comfort for years to come.