Vermont Casting D232 installation instructions Below Grade Installations, Step

Page 13
BELOW GRADE INSTALLATIONS

STEP 5

Measure the horizontal length requirement including a 2" overlap , i.e. from the elbow to the outside wall face plus 2" (or the distance required if installing a second 90) elbow. (Fig. 19).

Fig. 19

Always install horizontal venting on a level plane.

STEP 6

Note: If using the charcoal wall plate, Part #52202-CG, and collar, Part #52203-CG, put them in place before putting the pipe sections through the wall.

Use appropriate length of pipe sections - telescopic or fixed

-and install. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if necessary. (Fig. 20).

Fig. 20

Sealing vent pipe and firestop gaps with high temperature sealant will restrict cold air being drawn in around fireplace.

- 13

STEP 7

Apply high temperature sealant to 4" and 7" collars or the termination one inch away from crimped end. Guide the vent terminations 4" and 7" collars into their respective vent pipes. Double check that the vent pipes overlap the collars by 2". Secure the termination to the wall with screws provided and caulk around the wall plate to weatherproof.

Fig.

Support horizontal pipes every 3 feet (91 cm) with metal pipe straps.

Check fireplace to make sure it is levelled and properly positioned.

BELOW GRADE INSTALLATIONS

When it is not possible to meet the required vent terminal clearances of 12 inches (305mm) above grade level a starter vent kit is recommended. It allows installation depth of down to 7 inches (178mm) below grade level. The 7 inches is measured from the centre of the horizontal vent pipe as it penetrates through the wall.

If venting system is installed below ground, we recommend a window well with adequate and proper drainage.

Image 13
Contents FOR YOUR SAFETY FOR YOUR SAFETYFree-Standing Direct Vented Fireplaces MODEL D232Crimped Ends Venting Components TABLE OF CONTENTSCLEARANCE TO COMBUSTIBLES INSTALLATION AND OPERATING INSTRUCTIONSLOCATING YOUR GAS FIREPLACE PLEASE REVIEW THE FOLLOWINGI J H A K C D EG F BMODEL D232 FIREPLACE DIMENSIONSGAS LINE INSTALLATION GAS SPECIFICATIONSPREPARATION D232 CERTIFIED TOON/OFF SWITCH OR INSTALLATION OF REMOTE SWITCH FOR RN/RP GAS VALVEVALVE MILLIVOLT THERMOSTATLocation of Vent Termination GENERAL VENTING INFORMATIONF= clearance to outside comer see next page G= clearance to inside comer see next pageD CC E Termination ClearancesTWIST LOCK PIPES CRIMPED END PIPESGENERAL INFORMATION ON ASSEMBLING THE VENT PIPES Screw Holes VERTICAL SIDEWALL APPLICATIONS VERTICAL SIDEWALL INSTALLATIONS Total 270oTO USE THE VENT GRAPH Dimensions in FeetSIDEWALL VENTING GRAPH HORIZONTAL DIMENSIONBEAD OF SEALANT VENT PIPE ASSEMBLYSTEP STEPSTEP BELOW GRADE INSTALLATIONSSTEP STEPrun if the vertical exceeds VERTICAL THROUGH THE ROOF APPLICATIONSVERTICAL THRU THE ROOF APPLICATIONS TO INSTALL VERTICAL VENTINGCRIMPED ENDS VENTING COMPONENTS TWIST LOCK VENTING COMPONENTS GENERAL GLASS INFORMATION OPERATING INSTRUCTIONSLOUVRE REMOVAL TRIM REMOVALINSTALLATION OF LOGS & BURNER LAVA ROCK MATERIAL GLASS CLEANINGClean glass after first two weeks of operation FLAME ADJUSTMENT RN/RP MODELS MAINTENANCECLEANING PROCEDURE FLAME CHARACTERISTICSLIGHTING AND OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO TURN OFF GAS TO FIREPLACEHONEYWELL MILLIVOLT VALVE TROUBLE SHOOTING THE GAS CONTROL SYSTEMSTART CHECKSIT NOVA 820 MILLIVOLT VALVE SYMPTOMPOSSIBLE CAUSES CORRECTIVE ACTIOND232 REPLACEMENT PARTS LISTDESCRIPTION D232 FREESTANDING REPLACEMENT PARTS#1 - COMPLETE LOG SET OPTIONS REMOTE CONTROLFAN KIT - FK24 Page For Gas Appliance Products LIMITED WARRANTY & EXTENDED LIFE TIME PROTECTIONCFM Majestic, Inc