Vermont Casting D232 Maintenance, Flame Adjustment Rn/Rp Models, Cleaning Procedure

Page 20
MAINTENANCE

MAINTENANCE

1.

It is important to keep the burner and the burner

 

compartment clean. This must be done periodically, at

 

least once per season. (See Cleaning Procedure).

2.

Clean the brass trim using a soft clean cloth, slightly

 

dampened with lemon oil and buff with a soft clean

 

cloth. Do NOT use brass polish or household cleaners

FLAME ADJUSTMENT (RN/RP MODELS)

For units equipped with Hi/Lo valves, flame adjustment is accomplished by rotating the Hi/Lo adjustment knob located near the centre of the gas control. (Fig. 38 & 39)

 

as these products will damage the brass trim. Lemon

 

oil can be obtained at supermarkets or hardware

 

stores.

3.

The optional FK12 and FK24 Fan requires periodic

 

cleaning. Check the fan and the area around the fan

 

assembly and wipe or vacuum at least once per month

 

during the operating season.

4.

Contact your local representative to arrange an annual

 

service program.

I

Turn

counterclockwise

to increase

flame height.

L

H

O

Turn clockwise

to lower

flame height.

Fig. 38

CLEANING PROCEDURE

1.Turn off pilot light at gas valve.

2.Remove front glass.

3.Remove logs.

CAUTION: LOGS MAY BE HOT

4.Vacuum burner compartment especially around orifice/primary air openings.

5.Reinstall logs.

6.Check pilot and main burner operation.

7.Reinstall glass front.

8.Recheck pilot and main burner operation.

9.Check visually the flame pattern and compare with Fig. 39, 40a & b or 41.

Turn

 

 

Turn clockwise

counterclockwise

 

 

 

 

to increase

to decrease

 

 

I

L

flame height.

flame height.

H

 

 

O

 

 

 

 

Fig. 39

FLAME CHARACTERISTICS

It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to the pictorials illustrated below (Fig. 40a & b, or 41). If any of the flames appear abnormal call a service person.

3/8" - 1/2"

 

SIT PILOT

PSE PILOT

 

Fig. 40a

Fig. 40b

D232

 

Fig. 41

- 20 -

Image 20
Contents FOR YOUR SAFETY FOR YOUR SAFETYFree-Standing Direct Vented Fireplaces MODEL D232TABLE OF CONTENTS Crimped Ends Venting ComponentsINSTALLATION AND OPERATING INSTRUCTIONS CLEARANCE TO COMBUSTIBLESLOCATING YOUR GAS FIREPLACE PLEASE REVIEW THE FOLLOWINGA K C D EG F B I J HMODEL D232 FIREPLACE DIMENSIONSGAS SPECIFICATIONS GAS LINE INSTALLATIONPREPARATION D232 CERTIFIED TOINSTALLATION OF REMOTE SWITCH FOR RN/RP GAS VALVE ON/OFF SWITCH ORVALVE MILLIVOLT THERMOSTATGENERAL VENTING INFORMATION Location of Vent TerminationF= clearance to outside comer see next page G= clearance to inside comer see next pageTermination Clearances D CC ECRIMPED END PIPES TWIST LOCK PIPESGENERAL INFORMATION ON ASSEMBLING THE VENT PIPES Screw HolesVERTICAL SIDEWALL INSTALLATIONS VERTICAL SIDEWALL APPLICATIONSTotal 270oDimensions in Feet TO USE THE VENT GRAPHSIDEWALL VENTING GRAPH HORIZONTAL DIMENSIONVENT PIPE ASSEMBLY BEAD OF SEALANTSTEP STEPBELOW GRADE INSTALLATIONS STEPSTEP STEPVERTICAL THROUGH THE ROOF APPLICATIONS run if the vertical exceedsTO INSTALL VERTICAL VENTING VERTICAL THRU THE ROOF APPLICATIONSCRIMPED ENDS VENTING COMPONENTS TWIST LOCK VENTING COMPONENTS OPERATING INSTRUCTIONS GENERAL GLASS INFORMATIONLOUVRE REMOVAL TRIM REMOVALClean glass after first two weeks of operation GLASS CLEANINGINSTALLATION OF LOGS & BURNER LAVA ROCK MATERIAL MAINTENANCE FLAME ADJUSTMENT RN/RP MODELSCLEANING PROCEDURE FLAME CHARACTERISTICSFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING AND OPERATING INSTRUCTIONSLIGHTING INSTRUCTIONS TO TURN OFF GAS TO FIREPLACETROUBLE SHOOTING THE GAS CONTROL SYSTEM HONEYWELL MILLIVOLT VALVESTART CHECKSYMPTOM SIT NOVA 820 MILLIVOLT VALVEPOSSIBLE CAUSES CORRECTIVE ACTIONDESCRIPTION REPLACEMENT PARTS LISTD232 #1 - COMPLETE LOG SET FREESTANDING REPLACEMENT PARTSD232 FAN KIT - FK24 REMOTE CONTROLOPTIONS Page CFM Majestic, Inc LIMITED WARRANTY & EXTENDED LIFE TIME PROTECTIONFor Gas Appliance Products