Vermont Casting Preparation, Gas Specifications, D232 CERTIFIED TO, Gas Line Installation

Page 5
GAS SPECIFICATIONS

GAS SPECIFICATIONS

 

 

 

MAX.

MIN.

 

 

 

INPUT

INPUT

MODEL

FUEL

GAS CONTROL

B.T.U.H

B.T.U.H.

 

 

 

 

 

D232RN

Natural Gas

Millivolt Hi/Lo

30,000

21,000

D232RP

Propane Gas

Millivolt Hi/Lo

30,000

22,500

 

 

 

 

 

This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is available and used.

The installation of your Fireplace must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1 latest edition, or CAN 1 B1-149.1 and .2 Installation Code. (EXCEPTION: Do not derate this appliance for elevations up to 4,500 ft (1,370m). Maintain the manifold pressure at 3.5 inches W.C. for Natural Gas and 10 inches W.C. for LP gas.)

D232 CERTIFIED TO

ANSI.Z21.88b-1999 / CSA 2.33b - M99

Vented Gas Fireplace Heaters

GAS INLET & MANIFOLD PRESSURES

 

NATURAL
LP (Propane)
Input Minimum
4.5" wc
11" wc
Input Maximum
7" wc
13" wc

 

 

 

Manifold Pressure
3.5" wc
10" wc

PREPARATION

The use of wall paper adjacent to this fire- place is not recommended, as the high heat given off by this fireplace may adversely effect the binders in the adhesive used to apply the wallpaper.

Before beginning, remove the glass door from the fireplace. Also check to make sure there is no hidden damage to the fireplace. Take a minute and plan out the gas, vent and electrical supply. See Glass Removal Section.

GAS LINE INSTALLATION

When purging gas line, the front glass must be removed.

The gas pipeline can be brought in through the rear of the fireplace as well as the bottom. Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection. It is most convenient to bring the gas line in from the rear right side of the valve, as this allows fan installation or removal without disconnecting the gas line.

The gas line connection can be made with properly tinned 3/8" copper tubing, 3/8" rigid pipe or an approved flex connector. Since some municipalities have some additional local codes, it is always best to consult your local authority and the CAN/CGA- B149 (.1 or

.2) installation code.

FOR U.S.A Installations consult the current National Fuel Gas Code, ANSI Z223.1

Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.

The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control.

1/2" Gas Supply

1/2" X 3/8" Reducer

3/8" Nipple

3/8" X 3/8" Shut Off Valve

3/8" Nipple

3/8" Union

TYPICAL GAS LINE CONNECTION 3/8" Nipple

Fig. 2

- 5 -

Image 5
Contents FOR YOUR SAFETY FOR YOUR SAFETYFree-Standing Direct Vented Fireplaces MODEL D232Crimped Ends Venting Components TABLE OF CONTENTSCLEARANCE TO COMBUSTIBLES INSTALLATION AND OPERATING INSTRUCTIONSLOCATING YOUR GAS FIREPLACE PLEASE REVIEW THE FOLLOWINGI J H A K C D EG F BMODEL D232 FIREPLACE DIMENSIONSGAS LINE INSTALLATION GAS SPECIFICATIONSPREPARATION D232 CERTIFIED TOON/OFF SWITCH OR INSTALLATION OF REMOTE SWITCH FOR RN/RP GAS VALVEVALVE MILLIVOLT THERMOSTATLocation of Vent Termination GENERAL VENTING INFORMATIONF= clearance to outside comer see next page G= clearance to inside comer see next pageD CC E Termination ClearancesTWIST LOCK PIPES CRIMPED END PIPESGENERAL INFORMATION ON ASSEMBLING THE VENT PIPES Screw HolesVERTICAL SIDEWALL APPLICATIONS VERTICAL SIDEWALL INSTALLATIONSTotal 270oTO USE THE VENT GRAPH Dimensions in FeetSIDEWALL VENTING GRAPH HORIZONTAL DIMENSIONBEAD OF SEALANT VENT PIPE ASSEMBLYSTEP STEPSTEP BELOW GRADE INSTALLATIONSSTEP STEPrun if the vertical exceeds VERTICAL THROUGH THE ROOF APPLICATIONSVERTICAL THRU THE ROOF APPLICATIONS TO INSTALL VERTICAL VENTINGCRIMPED ENDS VENTING COMPONENTS TWIST LOCK VENTING COMPONENTS GENERAL GLASS INFORMATION OPERATING INSTRUCTIONSLOUVRE REMOVAL TRIM REMOVALClean glass after first two weeks of operation GLASS CLEANINGINSTALLATION OF LOGS & BURNER LAVA ROCK MATERIAL FLAME ADJUSTMENT RN/RP MODELS MAINTENANCECLEANING PROCEDURE FLAME CHARACTERISTICSLIGHTING AND OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO TURN OFF GAS TO FIREPLACEHONEYWELL MILLIVOLT VALVE TROUBLE SHOOTING THE GAS CONTROL SYSTEMSTART CHECKSIT NOVA 820 MILLIVOLT VALVE SYMPTOMPOSSIBLE CAUSES CORRECTIVE ACTIONDESCRIPTION REPLACEMENT PARTS LISTD232 #1 - COMPLETE LOG SET FREESTANDING REPLACEMENT PARTSD232 FAN KIT - FK24 REMOTE CONTROLOPTIONS Page CFM Majestic, Inc LIMITED WARRANTY & EXTENDED LIFE TIME PROTECTIONFor Gas Appliance Products