LIGHTING AND OPERATING INSTRUCTIONS

LIGHTING AND OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This fireplace has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.

B.BEFORE LIGHTING smell all around the fireplace area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHATTODOIFYOUSMELLGAS

Do not try to light any fireplace.

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this page.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to off position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn clockwise

to FOR YOUR SAFETY READ BEFORE LIGHTING "OFF". Do not force.

OFF

PILOT

LO

HI

it

ON

N

 

OFF

 

 

 

 

 

O

 

F

 

PILOT

T

P

OF

 

 

OLI

 

 

EURO SIT

SIT NOVA

HONEYWELL

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this page. If you don't smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal in manual).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwiseLIGHTING INSTRUCTIONS

to "PILOT".

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

OR

If knob does not pop up when released, stop and immediately call your service technician or gas

supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to "On"TO TURN OFF GAS TO FIREPLACE position.

13.For RN/RP appliances turn the On/Off switch to "On" position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

TO TURN OFF GAS TO FIREPLACE

1.

Turn the On/Off switch to Off position or set the

4.

Push in gas control knob slightly

 

thermostat to lowest setting.

 

and turn clockwise

to

2.

Turn off all electric power to the fireplace if service

 

"OFF". Do not force.

 

 

is to be performed.

5.

Close control access panel.

 

3.Open control access panel.

- 21 -

Image 21
Contents FOR YOUR SAFETY FOR YOUR SAFETYFree-Standing Direct Vented Fireplaces MODEL D232Crimped Ends Venting Components TABLE OF CONTENTSCLEARANCE TO COMBUSTIBLES INSTALLATION AND OPERATING INSTRUCTIONSLOCATING YOUR GAS FIREPLACE PLEASE REVIEW THE FOLLOWINGI J H A K C D EG F BMODEL D232 FIREPLACE DIMENSIONSGAS LINE INSTALLATION GAS SPECIFICATIONSPREPARATION D232 CERTIFIED TOON/OFF SWITCH OR INSTALLATION OF REMOTE SWITCH FOR RN/RP GAS VALVEVALVE MILLIVOLT THERMOSTATLocation of Vent Termination GENERAL VENTING INFORMATIONF= clearance to outside comer see next page G= clearance to inside comer see next pageD CC E Termination ClearancesTWIST LOCK PIPES CRIMPED END PIPESGENERAL INFORMATION ON ASSEMBLING THE VENT PIPES Screw HolesVERTICAL SIDEWALL APPLICATIONS VERTICAL SIDEWALL INSTALLATIONSTotal 270oTO USE THE VENT GRAPH Dimensions in FeetSIDEWALL VENTING GRAPH HORIZONTAL DIMENSIONBEAD OF SEALANT VENT PIPE ASSEMBLYSTEP STEPSTEP BELOW GRADE INSTALLATIONSSTEP STEPrun if the vertical exceeds VERTICAL THROUGH THE ROOF APPLICATIONSVERTICAL THRU THE ROOF APPLICATIONS TO INSTALL VERTICAL VENTINGCRIMPED ENDS VENTING COMPONENTS TWIST LOCK VENTING COMPONENTS GENERAL GLASS INFORMATION OPERATING INSTRUCTIONSLOUVRE REMOVAL TRIM REMOVALGLASS CLEANING INSTALLATION OF LOGS & BURNER LAVA ROCK MATERIALClean glass after first two weeks of operation FLAME ADJUSTMENT RN/RP MODELS MAINTENANCECLEANING PROCEDURE FLAME CHARACTERISTICSLIGHTING AND OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO TURN OFF GAS TO FIREPLACEHONEYWELL MILLIVOLT VALVE TROUBLE SHOOTING THE GAS CONTROL SYSTEMSTART CHECKSIT NOVA 820 MILLIVOLT VALVE SYMPTOMPOSSIBLE CAUSES CORRECTIVE ACTIONREPLACEMENT PARTS LIST D232DESCRIPTION FREESTANDING REPLACEMENT PARTS D232#1 - COMPLETE LOG SET REMOTE CONTROL OPTIONSFAN KIT - FK24 Page LIMITED WARRANTY & EXTENDED LIFE TIME PROTECTION For Gas Appliance ProductsCFM Majestic, Inc