Vermont Casting D232 installation instructions Termination Clearances, D Cc E

Page 8
Termination Clearances

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

Inside Corner

A =

 D A Manual background Combustible 6"(152mm)

Noncombustible

V2"(50mm)

Outside Corner

B = Combustible

6"(152mm)

VNoncombustible

Manual background B Manual background

Recessed Location

Manual backgroundManual background D Manual backgroundManual background

CC

Manual background E Manual background

V

Balcony -

Balcony -

with no side wall

with perpendicular side wall

G

V Manual backgroundManual background

G=

Combustible& Non-Combustible

12"(305mm)

H

V

J

Combustible & Non-Combustible

H = 24"(610mm)

J = 20"(508mm)

C = Maximum depth of 48" (1219mm) for recessed location.

D = Minimum width for back wall of a recessed location. Combustible 38"(965mm) Noncombustible 24"(610mm)

E = Clearance from corner in recessed location. Combustible 6"(152mm) Noncombustible 2"(50mm)

- 8 -

Image 8
Contents FOR YOUR SAFETY FOR YOUR SAFETYFree-Standing Direct Vented Fireplaces MODEL D232TABLE OF CONTENTS Crimped Ends Venting ComponentsINSTALLATION AND OPERATING INSTRUCTIONS CLEARANCE TO COMBUSTIBLESLOCATING YOUR GAS FIREPLACE PLEASE REVIEW THE FOLLOWINGA K C D EG F B I J HMODEL D232 FIREPLACE DIMENSIONSGAS SPECIFICATIONS GAS LINE INSTALLATIONPREPARATION D232 CERTIFIED TOINSTALLATION OF REMOTE SWITCH FOR RN/RP GAS VALVE ON/OFF SWITCH ORVALVE MILLIVOLT THERMOSTATGENERAL VENTING INFORMATION Location of Vent TerminationF= clearance to outside comer see next page G= clearance to inside comer see next pageTermination Clearances D CC ECRIMPED END PIPES TWIST LOCK PIPESGENERAL INFORMATION ON ASSEMBLING THE VENT PIPES Screw HolesVERTICAL SIDEWALL INSTALLATIONS VERTICAL SIDEWALL APPLICATIONSTotal 270oDimensions in Feet TO USE THE VENT GRAPHSIDEWALL VENTING GRAPH HORIZONTAL DIMENSIONVENT PIPE ASSEMBLY BEAD OF SEALANTSTEP STEPBELOW GRADE INSTALLATIONS STEPSTEP STEPVERTICAL THROUGH THE ROOF APPLICATIONS run if the vertical exceedsTO INSTALL VERTICAL VENTING VERTICAL THRU THE ROOF APPLICATIONSCRIMPED ENDS VENTING COMPONENTS TWIST LOCK VENTING COMPONENTS OPERATING INSTRUCTIONS GENERAL GLASS INFORMATIONLOUVRE REMOVAL TRIM REMOVALClean glass after first two weeks of operation GLASS CLEANINGINSTALLATION OF LOGS & BURNER LAVA ROCK MATERIAL MAINTENANCE FLAME ADJUSTMENT RN/RP MODELSCLEANING PROCEDURE FLAME CHARACTERISTICSFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING AND OPERATING INSTRUCTIONSLIGHTING INSTRUCTIONS TO TURN OFF GAS TO FIREPLACETROUBLE SHOOTING THE GAS CONTROL SYSTEM HONEYWELL MILLIVOLT VALVESTART CHECKSYMPTOM SIT NOVA 820 MILLIVOLT VALVEPOSSIBLE CAUSES CORRECTIVE ACTIONDESCRIPTION REPLACEMENT PARTS LISTD232 #1 - COMPLETE LOG SET FREESTANDING REPLACEMENT PARTSD232 FAN KIT - FK24 REMOTE CONTROLOPTIONS Page CFM Majestic, Inc LIMITED WARRANTY & EXTENDED LIFE TIME PROTECTIONFor Gas Appliance Products