Empire Comfort Systems VF24FP2-1, VF24FP3-1 Main Burner and Thermostat Operation

Page 16
10,000 BTU/HR
7,000 BTU/HR

Cleaning and Maintenance/Pilot Oxygen Depletion Sensor Pilot

When the pilot has a large yellow tip flame, clean the Oxygen Depletion Sensor as follows:

1.Clean the ODS pilot by loosening nut B from the pilot tubing. When this procedure is required, grasp nut A with an open end wrench.

2.Blow air pressure through the holes indicated by the arrows. This will blow out foreign materials such as dust, lint and spider webs. Tighten nut B also by grasping nut A.

Warning:

Never use needles, wires, or similar cylindrical objects to clean the pilot to avoid damaging the calibrated ruby that controls the gas flow.

Figure 19

MAIN BURNER AND THERMOSTAT OPERATION

The VF24FP2-1 gas control maximum and minimum inputs are listed below.

OFF is the OFF position.

PILOT is the PILOT position.

VF24FP2-1

Max.

20,000 BTU/HR

Min.

7,000 BTU/HR

VF24FP2-1 can be converted to 10,000 BTU for Bedroom Installation

Max.

Min.

VF24FP3-1 Main Burner Operation

The gas control modulates from a minimum input of 14,000 BTU/HR (LO setting) to a maximum input of 20,000 BTU/HR (HI setting).

Cleaning and Maintenance / Main Burner Warning: Turn off heater and let cool before cleaning.

Caution: You must keep control areas, burner and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding materials, etc.

Logs

Be careful cleaning and handling logs so as not to damage them. If logs break or fall apart in handling, spray the broken pieces and fibers with water, sweep up and discard.

VF24FP2-1: CONVERSION TO 10,000 BTU'S FOR BEDROOM INSTALLATION

For installation in a bedroom the VF24FP2-1, 20,000 BTU input must be converted to a 10,000 input fireplace.

Attention: Main burner orifice for conversion to 10,000 BTU's is located in your Owner's Envelope.

Bedroom Installation: VF24FP2-1 Only

The bedroom must be an unconfined space. ANSI Z223.1/NFPA54 defines an unconfined space as “a space whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space.”

Refer to "Provisions for Adequate Combustion and Ventilation Air," Page 6.

Instructions for Conversion of a VF24FP2-1 into a 10,000 BTU unit:

1.If installed, turn OFF gas supply to fireplace.

2.Lift upward to remove screen front.

3.Remove logs from fireplace.

4.Remove rear log support from inner casing [three (3) 10 x 1/2" screws].

5.Disconnect supply tubing from orifice fitting.

6.Remove air shutter and orifice fitting from venturi (throat) of main burner by removing one (1) Phillips screw.

7.For Natural gas only, remove coupling from orifice fitting.

8.Remove air shutter from orifice fitting.

9.For Natural gas only, remove 20,000 BTU main burner orifice marked 49 from orifice fitting and replace with 10,000 BTU

main burner orifice marked 1.30mm.

9.For Propane (LP) gas only, remove 20,000 BTU, main burner orifice marked 55 from orifice fitting and replace with 10,000 BTU main burner orifice marked 64.

10. Replace air shutter onto orifice fitting.

11. For Natural gas only, replace coupling onto orifice fitting. 12. Attach air shutter and orifice fitting onto venturi (throat) of

main burner with one (1) Phillips screw from Step 6. Attention: Air shutter will have a 1/16" opening on Natural gas. Air shutter will be fully open on Propane (LP) gas.

13. Attach supply tubing onto orifice fitting.

14. Attach rear log support to inner casing with three (3) 10 x 1/2" screws from Step 4.

15. Turn on gas supply to fireplace and check all gas connections for leaks with soap solution, watching for bubbles on all gas connections.

16. Install logs into fireplace, refer to "Log Placement", Page 12.

17. Replace screen front onto fireplace.

18. Check main burner flame for proper flame characteristics. Refer to "Operation Instructions/Flame Appearance, Page 20.

19. Refer to rating plate in order to check box for which installation applies, either 20,000 or 10,000 BTU input.

20. Conversion from 20,000 BTU to 10,000 BTU input fireplace is completed.

Page 16

20248-2-0806

Image 16
Contents Installation Instructions Table of Contents Important Safety Information Do not Tamper with Pilot Light SafetyCarbon Monoxide Poisoning MAY Lead to DeathSafety Information for Users of LP-GAS LP-GAS Warning OdorIntroduction Specifications Water Vapor a BY-PRODUCT of Unvented Room HeatersVentilation Air From Inside Building OutdoorsVentilation AIR Ventilation Air From OutdoorsGAS Supply Recommended Gas Pipe DiameterClearances Combustible MaterialInstallation of Trim Installation of Fireplace Into MantelInstalling Fireplace in Mantel BUILT-IN Fireplace Installation Built-In Fireplace InstallationRough Opening for Installing in Wall Rough Opening for Installing in CornerLOG Placement Placement of Glowing Embers Rock WoolReplacement Loose Material glowing embers Part Number Operation INSTRUCTIONS/FLAME AppearanceVF24FP3-1 Lighting Instructions What to do if YOU Smell GASVF24FP2-1 Lighting Instructions Lighting InstructionsVF24FP3-1 Pilot Pilot Flame CharacteristicsVF24FP2-1 Pilot Bedroom Installation VF24FP2-1 Only Main Burner and Thermostat OperationVF24FP2-1 VF24FP3-1 Main Burner OperationCheck 750 Millivolt System Operation Remote ReceiverGas odor even when control knob is in OFF position Heater produces a whistling noise when main burner is litAppliance produces unwanted odors Appliance shuts off during use. Pilot stays onHOW to Order Repair Parts Parts ListIndex Part Description Number Parts View Installing Optional Brick Liner EHL-24-1 Optional Brick Liner Installation InstructionsParts List for EHL-24-1, Brick Liner KIT Optional Blower Installation Instructions Installing Optional Blower VFS-BK20248-2-0806 Optional Blower Installation Instructions VFS-BK Parts List WiringOiling Blower Motor Parts List and Parts View for Optional Trim Kits VPF24SS Stainless SteelService Notes