Empire Comfort Systems VF24FP2-1, VF24FP3-1 Appliance produces unwanted odors, No gas to pilot

Page 18

TROUBLESHOOTING

SYMPTOMS, POSSIBLE CAUSES AND CORRECTIONS

Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater.

1.When ignitor button is pressed, there is no spark at ODS/ pilot.

a.Ignitor electrode positioned wrong - Replace pilot.

b.Ignitor electrode is broken - Replace pilot.

c.Ignitor electrode not connected to ignitor cable - Reconnect ignitor cable.

d.Ignitor cable pinched or wet. Keep ignitor cable dry - Free ignitor cable if pinched by any metal or tubing.

e.Broken ignitor cable - Replace ignitor cable.

f.Bad piezo ignitor - Replace piezo ignitor.

2.Appliance produces unwanted odors.

a.Appliance burning vapors from paint, hair spray, glues, etc.

-Ventilate room. Stop using odor causing products while heater is running.

b.Gas leak - Locate and correct all leaks.

3.Appliance shuts off during use. (Pilot and main burner are off.)

a.Not enough fresh air is available for ODS/pilot to operate

-Open window and/or door for ventilation.

b.Low line pressure - Contact local gas company.

c.ODS/pilot is partially clogged - Clean ODS/pilot.

d.Defective thermocouple - Replace pilot.

4.Appliance shuts off during use. (Pilot stays on.)

a.Low line pressure - Check line pressure to the valve.

b.Defective thermopile - Check pilot flame, check wire con- nections, output should be a minimum of 325 millivolts across. TH/TP and TP terminals with ON/OFF switch off.

5.Gas odor even when control knob is in OFF position.

a.Gas leak - Locate and correct all leaks.

b.Control valve defective - Replace control valve.

6.When ignitor button is pressed, there is spark at ODS/pilot, but no ignition.

a.Gas supply turned off or manual shutoff valve closed - Turn on gas supply or open manual shutoff valve.

b.Control knob not in PILOT position - Turn control knob to PILOT position.

c.Control knob not pressed in while in PILOT position - Press in control knob while in PILOT position.

d.Air in gas lines when installed - Continue holding down con- trol knob. Repeat igniting operation until air is removed.

e.ODS/pilot is clogged - Replace ODS/pilot assembly or get it serviced.

f.Gas regulator setting is not correct - Replace gas regula- tor.

7.ODS/pilot lights but flame goes out when control knob is released.

a.Control knob not fully pressed in - Press in control knob fully.

b.Control knob not pressed in long enough - After ODS/pilot lights, keep control knob pressed in 30 seconds.

c.Manual Shutoff valve not fully open - Fully open manual

shutoff valve.

d.Thermocouple connection loose at control valve - Hand tighten until snug, then tighten 1/4 turn more.

e.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by either low gas pressure or dirty or partially clogged ODS/pilot - Contact local gas company.

f.Thermocouple damaged - Replace thermocouple.

g.Control valve damaged - Replace control valve.

8.Burner does not light after ODS/pilot is lit.

a.Burner orifice clogged - Clean burner or replace main burner orifice.

b.Burner orifice diameter is too small - Replace burner ori- fice.

c.Inlet gas pressure is too low - Contact qualified service person.

9.If burning at main burner orifice occurs (a loud, roaring blow torch noise).

a.You must turn off burner assembly and contact a qualified service person.

b.Manifold pressure is too low - Contact local gas com- pany.

c.Burner orifice clogged - Clean burner or replace burner orifice.

10.Logs appear to smoke after initial operation.

a.Vapors from paint or curing process of logs - Problem will stop after a few hours of operation. Run the heater with the damper open if you have one, or open a window for the first few hours.

Log heater is intended to be smokeless. Turn OFF heater and call qualified service person.

11.Heater produces a whistling noise when main burner is lit.

a.Turning control knob to HIGH position when main burner is cold - Turn control knob to LOW position and let warm up for a minute.

b.Air in gas line - Operate burner until air is removed from line. Have gas line checked by local gas company.

c.Dirty or partially clogged burner orifice - Clean burner or replace burner orifice.

12.No gas to pilot.

a.LP-regulator shut down due to inlet pressure too high - Verify LP tank regulator is installed and set at 11" to 13" w.c. Replace regulator on heater.

If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately.

Page 18

20248-2-0806

Image 18
Contents Installation Instructions Table of Contents Carbon Monoxide Poisoning MAY Lead to Important Safety InformationDo not Tamper with Pilot Light Safety DeathSafety Information for Users of LP-GAS LP-GAS Warning OdorIntroduction Specifications Water Vapor a BY-PRODUCT of Unvented Room HeatersVentilation AIR Ventilation Air From Inside BuildingOutdoors Ventilation Air From OutdoorsGAS Supply Recommended Gas Pipe DiameterClearances Combustible MaterialInstallation of Fireplace Into Mantel Installation of TrimInstalling Fireplace in Mantel Rough Opening for Installing in Wall BUILT-IN Fireplace InstallationBuilt-In Fireplace Installation Rough Opening for Installing in CornerReplacement Loose Material glowing embers Part Number LOG PlacementPlacement of Glowing Embers Rock Wool Operation INSTRUCTIONS/FLAME AppearanceVF24FP3-1 Lighting Instructions What to do if YOU Smell GASVF24FP2-1 Lighting Instructions Lighting InstructionsPilot Flame Characteristics VF24FP3-1 PilotVF24FP2-1 Pilot VF24FP2-1 Bedroom Installation VF24FP2-1 OnlyMain Burner and Thermostat Operation VF24FP3-1 Main Burner OperationCheck 750 Millivolt System Operation Remote ReceiverAppliance produces unwanted odors Gas odor even when control knob is in OFF positionHeater produces a whistling noise when main burner is lit Appliance shuts off during use. Pilot stays onParts List HOW to Order Repair PartsIndex Part Description Number Parts View Optional Brick Liner Installation Instructions Installing Optional Brick Liner EHL-24-1Parts List for EHL-24-1, Brick Liner KIT Optional Blower Installation Instructions Installing Optional Blower VFS-BK20248-2-0806 Optional Blower Installation Instructions Wiring VFS-BK Parts ListOiling Blower Motor Parts List and Parts View for Optional Trim Kits VPF24SS Stainless SteelService Notes