Drolet DG05437/DG05447 manual Installation, Safety Notice, Positioning The Fireplace

Page 11
INSTALLATION

ULTRA FLAME DV “0” Clearance Fireplace

INSTALLATION

SAFETY NOTICE

Improper installation may result in a house fire. Follow installation directions. Installation must be in accordance with local building codes or, in the absence of local codes, with current CAN/CGA B 149 installation codes for gas appliances in Canada and current National Fuel Gas Code ANSI Z223.1 in the USA.

INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER.

THIS GAS FIREPLACE MUST BE VENTED OUTSIDE.

THIS GAS FIREPLACE, WHEN INSTALLED WITH OPTIONAL BLOWER OR HAND HELD REMOTE, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE National Electrical Code, ANSI/FPA 70, or the CANADIAN ELECTRICAL CODE, CSA C22.1.

POSITIONING THE FIREPLACE

WARNING: Because of high operating temperatures, the ULTRA FLAME should be located away from high traffic areas, furniture, curtains, and other combustible material.

Always locate the fireplace as near as possible to an outside wall to keep vent length to a minimum.

Provide adequate accessibility clearances for servicing and proper operation.

Provide adequate clearances around air openings into the combustion chamber.

The ULTRA FLAME may be installed in a bedroom provided that all required clearances are met and a wall thermostat is installed.

Never install the fireplace in a hallway or near a staircase as it may block the way in case of a fire.

If the appliance is being installed on combustible flooring, such as directly on carpeting, tile, or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

A GAS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID-FUEL BURNING APPLIANCE.

11

Image 11
Contents DIRECT VENT 0 CLEARANCE GAS FIREPLACE INSTALLATION AND OPERATING INSTRUCTIONSFOR YOUR SAFETY FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GASGLASS MAINTENANCE SPECIFICATIONSLIGHTING PROCEDURE MAINTENANCE INSTRUCTIONSKEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE GENERAL INFORMATIONDO NOT MODIFY THIS APPLIANCE SPECIFICATIONS THE FIRST FIRE LIGHTING PROCEDUREOPERATION BEFORE LIGHTINGBLOWER WALL THERMOSTATSHUTDOWN Use only a cleaner recommended by your dealer MAINTENANCE INSTRUCTIONSGLASS MAINTENANCE Never clean this glass with abrasive cleanersBURST DISC REPLACEMENT SIDE VIEW TOP, FRONT AND SIDE VIEWSFRONT VIEW TOP VIEWPOSITIONING THE FIREPLACE INSTALLATIONSAFETY NOTICE VENT TERMINAL LOCATION MINIMUM CLEARANCE TO COMBUSTIBLES INSTALLATION OF THE UNIT WARNING DO NOT USE OPEN FLAME TO CHECK LEAKS BASEMENT VENTING KITSSTRAIGH OUT CORNER2 CORNER INSTALLATION 1 STRAIGHT OUT INSTALLATION3 BASEMENT INSTALLATION ULTRA FLAME DV “0” Clearance Fireplace VENTING SYSTEMVENT TERMINAL, BASEMENT INSTALLATION OPTIONAL BLOWER INSTALLATION VENT TERMINAL, ROOF INSTALLATIONBURNER REMOVAL AND INSTALLATION GLASS FRONT REMOVAL, CLEANING AND INSTALLATIONEMBER KIT INSTALLATION LOG INSTALLATION LOUVRE INSTALLATION ULTRA FLAME DV “0” Clearance Fireplace OPTIONAL REFRACTORY PANEL INSTALLATION1.Remove the glass front assembly 6.Install the glass front assemblyELEVATION ADJUSTMENTSNatural Gas Pressure Settings Propane Pressure SettingsRemember to replace all covers ADJUSTING THE GAS PRESSUREWALL THERMOSTAT ADJUSTING AIR SHUTTERITEM DESCRIPTION REPLACEMENT PARTSOPTIONAL PARTS ITEM DESCRIPTIONDROLET STOVES AND FIREPLACES INC LIMITED 5 YEAR WARRANTY