Drolet DG05437/DG05447 manual Specifications

Page 5
SPECIFICATIONS

ULTRA FLAME DV “0” Clearance Fireplace

 

SPECIFICATIONS

Dimensions:

height 39", width 36", depth 20"

Glass:

29-1/8" x 17-3/4" 1400oF clear ceramic

Minimum opening in wall for installing the units: height: 39-1/2"

width: 36-1/2"

Fuel:

Natural Gas

Propane

 

Input :

30,000/ 20,000

26,000/20,000

Btu/h

Manifold pressure :

3.5/1.8

 

10.5/7.0

in w.c.

Min. inlet pressure :

5

 

11

in w.c.

Max. inlet pressure :

7

 

14

in w.c.

Efficiency:

75%

 

 

 

Vent size:

4" inner 8" outer coaxial vent pipes

 

Valve:

SIT Model Nova 820 adjustable millivolt valve

 

Blower:

Variable speed, 200 CFM

 

 

Thermo-switch:

120oF "ON", 90oF "OFF" bi-metal type

 

Pressure relief device: Burst disc

 

 

 

Maximum length of venting pipe allowed:

 

 

Straight out installation:

- Vertical rise: 0’

 

 

 

- Max horizontal length: 5'

 

 

 

- Max combination of both: 5’

 

Corner installation:

- Vertical rise: 0’

 

 

 

- Max horizontal length: 5'

 

 

 

- Max combination of both: 5’

 

Basement installation:

- Max vertical rise: 25'

 

 

 

- Max horizontal length: 10'

 

 

 

- Max combination of both: 25'

 

Maximum number of elbows 90° or 45°: 3

5

Image 5
Contents FOR YOUR SAFETY INSTALLATION AND OPERATING INSTRUCTIONSFOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS DIRECT VENT 0 CLEARANCE GAS FIREPLACELIGHTING PROCEDURE SPECIFICATIONSMAINTENANCE INSTRUCTIONS GLASS MAINTENANCEKEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE GENERAL INFORMATIONDO NOT MODIFY THIS APPLIANCE SPECIFICATIONS OPERATION LIGHTING PROCEDUREBEFORE LIGHTING THE FIRST FIREBLOWER WALL THERMOSTATSHUTDOWN GLASS MAINTENANCE MAINTENANCE INSTRUCTIONSNever clean this glass with abrasive cleaners Use only a cleaner recommended by your dealerBURST DISC REPLACEMENT FRONT VIEW TOP, FRONT AND SIDE VIEWSTOP VIEW SIDE VIEWPOSITIONING THE FIREPLACE INSTALLATIONSAFETY NOTICE VENT TERMINAL LOCATION MINIMUM CLEARANCE TO COMBUSTIBLES INSTALLATION OF THE UNIT WARNING DO NOT USE OPEN FLAME TO CHECK LEAKS STRAIGH OUT VENTING KITSCORNER BASEMENT2 CORNER INSTALLATION 1 STRAIGHT OUT INSTALLATION3 BASEMENT INSTALLATION ULTRA FLAME DV “0” Clearance Fireplace VENTING SYSTEMVENT TERMINAL, BASEMENT INSTALLATION OPTIONAL BLOWER INSTALLATION VENT TERMINAL, ROOF INSTALLATIONBURNER REMOVAL AND INSTALLATION GLASS FRONT REMOVAL, CLEANING AND INSTALLATIONEMBER KIT INSTALLATION LOG INSTALLATION LOUVRE INSTALLATION 1.Remove the glass front assembly OPTIONAL REFRACTORY PANEL INSTALLATION6.Install the glass front assembly ULTRA FLAME DV “0” Clearance FireplaceNatural Gas Pressure Settings ADJUSTMENTSPropane Pressure Settings ELEVATIONRemember to replace all covers ADJUSTING THE GAS PRESSUREWALL THERMOSTAT ADJUSTING AIR SHUTTEROPTIONAL PARTS REPLACEMENT PARTSITEM DESCRIPTION ITEM DESCRIPTIONDROLET STOVES AND FIREPLACES INC LIMITED 5 YEAR WARRANTY