INSTALLATION

VENTING

INSTALLATION

SAFETY PRECAUTIONS

INTRODUCTION

PRECAUTIONS

FOR THE INSTALLER

The HorizontalTermination Kit and the Simpson Dura-Vent Direct Vent System Model DV-GS venting systems, in combination with the Direct Vent Freestanding Gas Stoves, H15-NG1, and H15-LP1, have been tested and listed as direct vent heater systems by Warnock Hersey.

These units use the "balanced fl ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combus- tion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

Note: These flue pipes must not be connected to any other appliance.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

IMPORTANT

Read all instructions carefully before starting the installation. Failure to follow these instruc- tions may create a fi re or other safety hazard, and will void the warranty. Be sure to check the venting and clearance to combustible require- ments. Consult your local building codes before beginning installation.

The location of the termination cap must con- form to the requirements in the "Exterior Vent Terminal Locations" section.

These venting systems are engineered products that have been designed and tested for use with the H15-NG1, and H15-LP1. The warranty will be voided and serious fi re, health or other safety hazards may result from any of the fol- lowing actions:

1)Installation of any damaged Rigid Pipe component.

2)Unauthorized modification of any Rigid Pipe System.

3)Installation other than as instructed by Simp- son Dura-Vent and FPI Fireplace Products International Ltd.

Warning: Always maintain required clearances (air spaces) to nearby combustibles to prevent a fire hazard. Do not fill air spaces with insulation.

Be sure to check the vent termination clearance requirements from decks, windows, soffi ts, gas regulators, air supply inlets and public walkways as specifi ed in the "Exterior Vent Terminal Locations" section and in your local building codes.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appli- ance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

1)Wear gloves and safety glasses for protec- tion.

2)Exercise extreme caution when using lad- ders or on roof tops.

3)Be aware of electrical wiring locations in walls and ceilings.

VENT RESTRICTOR

POSITION

To set the Vent restriction as indicated in the Venting Arrangement diagrams in the "Rigid Pipe Venting System" section, simply loosen the screws and push the vent restrictor plate to the correct position. Tighten the screws. This will be located inside the fi rebox.

1)Remove top casting.

2)Remove all 4 screws that secure the elbow to the unit using a 1/4" magnetic nut driver.

Remove all 4 screws

and washers

ROTATING ELBOW

3)Rotate the elbow 180o

4)Secure the elbow by securing it with the 4 screws.

10

Hampton® H15-1 Direct Vent Freestanding Gas Stove

Image 10
Contents H15 Direct Vent Gas Fireplace 918-516a 12/17/07Hampton Unit DimensionsTo the New Owner Table of Contents Safety Label Requirements MA Code CO DetectorImportant Message Save These Instructions InstallationSpecifications Mobile Manufactured Homes After First SaleClearances to Combustibles General Safety InformationInstallation Checklist This includesManufactured Mobile Home Additional Requirements InstallationOptional FAN Fan Kit ContainsWires Lug Nut Rear PlateRotating Elbow PrecautionsVent Restrictor Position Remove all 4 screws WashersExterior Vent Terminal Locations 6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Horizontal Rigid Pipe Venting SystemsAlternate CapsHorizontal Venting with Two 2 90o Elbows + H1 With these options, maxMin Max Min. pipe length is 30 feet with min Vertical Venting with Two 2 90o ElbowsFeet total horizontal Venting Arrangements Straight Vertical Terminations Vertical Termination with CO-LINEAR Flex SystemRequired Parts DescriptionDV Stove Horizontal Vent KIT Qty. DescriptionOn a siding cov- ered wall, a vinyl siding standoff Kit #640-944 Kit #380-946 Planning Your Venting InstallationMinimum components for a Horizontal Installation 640-545/P Decorative Wall Trim Black Tube Mill-Pac ScrewsDura-Vent Basic Horizontal Kit # Planning Your Dura-Vent InstallationDURA-VENT Termination KIT 90o Elbow Wall Thimble Cover Horiz. Sq. Term. CapMinimum components for a Dura-Vent Verti- cal Termination Below Grade Snorkel InstallationHorizontal Terminations Snorkel TerminationsVertical Terminations Seal around the outer edge of the Riser Vent Backing PlateOffset Chart Continue to assemble pipe lengthsVent System Approved for US Installations OnlyConverting a Factory Built Metal Chimney High Elevation Cathedral CeilingsGAS Connection Valve Description Conversion KIT# 381-969 from NG to LP LPG Conversion Kit Contains QtyInstallation of the DC Sparker Velcro Remove Glass Door LOG SET InstallationInside View Left Front Log Right Front LogLogs must be oriented as shown below Final Check Wire Size Max. LengthConnect the wires as per the wiring diagram below Check for proper draftWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsPilot Adjustment MaintenanceMaintenance Instructions Normal Operating Sounds of GAS AppliancesFAN Maintenance General Vent MaintenanceGlass Replacement LOG ReplacementRemoving Valve Installing Valve AssemblyTo remove valve from valve assembly, continue ScrewsParts List Main AssemblyBurner & LOG Assembly 910-039Hampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information

H15-LP1, H15-NG1 specifications

Hampton Direct has established a reputation for producing innovative and high-quality products, and their H15-NG1 and H15-LP1 appliances are no exceptions. These two models have been thoughtfully designed to cater to different needs while sharing several essential features that promise reliability and performance.

The H15-NG1 is designed as a natural gas appliance, ideal for users who prefer the efficiency and cost-effectiveness of natural gas heating. Its advanced technology ensures that it operates smoothly and efficiently, providing consistent heating without compromising safety. Users can appreciate the integrated safety features, including automated shut-off mechanisms and flame detection systems. The H15-NG1 also has adjustable heat settings, giving users the flexibility to control the temperature according to their requirements.

On the other hand, the H15-LP1 is specifically designed for propane users. This model is perfect for those who utilize propane as a primary energy source in their households. Similar to its counterpart, the H15-LP1 boasts a powerful heating system that can quickly warm up large spaces, making it an excellent choice for both indoor and outdoor applications. It also includes safety features such as a pressure regulator, ensuring a stable flow of propane that enhances both efficiency and safety.

Both the H15-NG1 and H15-LP1 are constructed with durable materials, ensuring longevity and resilience in various conditions. They are easy to install and user-friendly, making them suitable for users of all experience levels.

Another significant feature of both models is their energy efficiency, which not only provides savings on utility bills but also contributes to an eco-friendly lifestyle. They are equipped with innovative heating technology that maximizes heat output while minimizing energy consumption. This focus on sustainability aligns with contemporary standards for energy-efficient home appliances.

In summary, the Hampton Direct H15-NG1 and H15-LP1 offer impressive features and technologies designed to meet diverse heating needs. With a commitment to safety, efficiency, and user convenience, these models stand out as reliable choices for homeowners looking for effective heating solutions. Whether you prefer natural gas or propane, both units promise a blend of performance, durability, and ease of use.