Hampton Direct H15-NG1, H15-LP1 DURA-VENT Termination KIT, Planning Your Dura-Vent Installation

Page 22

INSTALLATION

DURA-VENT TERMINATION KIT

Planning Your Dura-Vent

Installation

There are two basic types of Dura-Vent Direct Vent System installations: horizontal termination and vertical termination. Confi rm the maximum horizontal run and maximum vertical rise from the diagrams in the "Rigid Pipe Venting Sys- tems" section.

When planning your installation, it will be nec- essary to select the proper length of vent pipe for your particular requirements. For horizontal installations, determine the minimum clearance from the rear of the unit to the wall. It is also

important to note the wall thickness. (The wall thimble is suitable for 2 x 4 or 2 x 6 wall construction.) Select the amount of vertical rise desired for "vertical-to-horizontal" type installations.

Warning: Alwaysmaintainrequired clearances (air spaces) to nearby combustibles to prevent a fire hazard. Do not fill air spaces with insulation.

The minimum clearance requirements between the outer wall of the vent pipe and nearby com- bustible surfaces is 1-1/4 inch. Be sure to check

the vent termination clearance requirements from decks, windows, soffi ts, gas regulators, air supply inlets and public walkways as specifi ed in the "Exterior VentTerminal Locations" section and in your local building codes.

To determine the length of vent pipe required for vertical installations, measure the distance from the unit fl ue outlet to the ceiling, the ceiling thickness, the vertical rise in an attic or second storey, and allow for suffi cient vertical height above the roof line.

For multi-storey applications, fi re stops are required at each fl oor level. If an offset is needed, additional pipe, elbows and supports will be required.

Do not exceed the maximum number of elbows. One 90o for horizontal terminations and two 45o for vertical termination.

Dura-Vent Basic

Horizontal Kit # 970

190o Elbow

1Wall Thimble Cover

1Horiz. Sq. Term. Cap

Alternate Horizontal

Termination Caps

AstroCap

Part# 946-523/P

Alternate

Horizontal

Riser Vent

Terminal

Part# 640-530/P

TheFPIAstroCapTMiscertifiedforinstallationsusingFPIventingsystems as well as Simpson Dura-Vent® and Direct Vent GS.

The FPI AstroCapTM is a proprietary trademark of FPI Fireplace Prod- ucts International Ltd.

Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

22

Hampton® H15-1 Direct Vent Freestanding Gas Stove

Image 22
Contents H15 Direct Vent Gas Fireplace 918-516a 12/17/07Hampton Unit DimensionsTo the New Owner Table of Contents Safety Label Requirements MA Code CO DetectorImportant Message Save These Instructions InstallationSpecifications Mobile Manufactured Homes After First SaleClearances to Combustibles General Safety InformationInstallation Checklist This includesManufactured Mobile Home Additional Requirements InstallationOptional FAN Fan Kit ContainsWires Lug Nut Rear PlateRotating Elbow PrecautionsVent Restrictor Position Remove all 4 screws WashersExterior Vent Terminal Locations 6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Horizontal Rigid Pipe Venting SystemsAlternate CapsHorizontal Venting with Two 2 90o Elbows + H1 With these options, maxMin Max Min. pipe length is 30 feet with min Vertical Venting with Two 2 90o ElbowsFeet total horizontal Venting Arrangements Straight Vertical Terminations Vertical Termination with CO-LINEAR Flex SystemRequired Parts DescriptionDV Stove Horizontal Vent KIT Qty. DescriptionOn a siding cov- ered wall, a vinyl siding standoff Kit #640-944 Kit #380-946 Planning Your Venting InstallationMinimum components for a Horizontal Installation 640-545/P Decorative Wall Trim Black Tube Mill-Pac ScrewsDura-Vent Basic Horizontal Kit # Planning Your Dura-Vent InstallationDURA-VENT Termination KIT 90o Elbow Wall Thimble Cover Horiz. Sq. Term. CapMinimum components for a Dura-Vent Verti- cal Termination Below Grade Snorkel InstallationHorizontal Terminations Snorkel TerminationsVertical Terminations Seal around the outer edge of the Riser Vent Backing PlateOffset Chart Continue to assemble pipe lengthsVent System Approved for US Installations OnlyConverting a Factory Built Metal Chimney High Elevation Cathedral CeilingsGAS Connection Valve Description Conversion KIT# 381-969 from NG to LP LPG Conversion Kit Contains QtyInstallation of the DC Sparker Velcro Remove Glass Door LOG SET InstallationInside View Left Front Log Right Front LogLogs must be oriented as shown below Final Check Wire Size Max. LengthConnect the wires as per the wiring diagram below Check for proper draftWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsPilot Adjustment MaintenanceMaintenance Instructions Normal Operating Sounds of GAS AppliancesFAN Maintenance General Vent MaintenanceGlass Replacement LOG ReplacementRemoving Valve Installing Valve AssemblyTo remove valve from valve assembly, continue ScrewsParts List Main AssemblyBurner & LOG Assembly 910-039Hampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information

H15-LP1, H15-NG1 specifications

Hampton Direct has established a reputation for producing innovative and high-quality products, and their H15-NG1 and H15-LP1 appliances are no exceptions. These two models have been thoughtfully designed to cater to different needs while sharing several essential features that promise reliability and performance.

The H15-NG1 is designed as a natural gas appliance, ideal for users who prefer the efficiency and cost-effectiveness of natural gas heating. Its advanced technology ensures that it operates smoothly and efficiently, providing consistent heating without compromising safety. Users can appreciate the integrated safety features, including automated shut-off mechanisms and flame detection systems. The H15-NG1 also has adjustable heat settings, giving users the flexibility to control the temperature according to their requirements.

On the other hand, the H15-LP1 is specifically designed for propane users. This model is perfect for those who utilize propane as a primary energy source in their households. Similar to its counterpart, the H15-LP1 boasts a powerful heating system that can quickly warm up large spaces, making it an excellent choice for both indoor and outdoor applications. It also includes safety features such as a pressure regulator, ensuring a stable flow of propane that enhances both efficiency and safety.

Both the H15-NG1 and H15-LP1 are constructed with durable materials, ensuring longevity and resilience in various conditions. They are easy to install and user-friendly, making them suitable for users of all experience levels.

Another significant feature of both models is their energy efficiency, which not only provides savings on utility bills but also contributes to an eco-friendly lifestyle. They are equipped with innovative heating technology that maximizes heat output while minimizing energy consumption. This focus on sustainability aligns with contemporary standards for energy-efficient home appliances.

In summary, the Hampton Direct H15-NG1 and H15-LP1 offer impressive features and technologies designed to meet diverse heating needs. With a commitment to safety, efficiency, and user convenience, these models stand out as reliable choices for homeowners looking for effective heating solutions. Whether you prefer natural gas or propane, both units promise a blend of performance, durability, and ease of use.