INSTALLATION
RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES
MINIMUM HORIZONTAL TERMINATION INSTALLATIONS
Planning Your Venting Installation
See the "Exterior Vent Terminal Locations" section for requirements.
When planning your installation, it will be nec- essary to select the proper length of vent pipe for your particular requirements. Determine the minimum clearance to combustibles from the rear of the unit to the wall. It is also important to note the wall thickness. Before cutting the vent hole through the wall ensure that ALL vent and termination clearances (Refer to the "Exterior Vent Terminal Locations" section) will be met.
*Ifthisisanoutsidecorner,theminimumdistance between the vent and the outside corner is 6" (15cm). See "F" on the diagram in the "Exterior Vent Terminal Locations" section.
You will require the following components with your new Hampton® Direct Vent Freestanding Gas Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer. Decorative brass or chrome trim kits are available from Simpson
Note: These are the minimum pieces required. Other parts may be required for your par- ticular installation.
NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met.
Kit #640-944
Kit #380-946
Minimum components for a Horizontal Installation:
1
14" Dia. x 18" Aluminum Vent
1
1
1
1
1
14" Dia. x 12" Aluminum Vent
1
1 | AstroCap |
1640-545/P Decorative Wall Trim (Black)
1948-128 Tube Mill-Pac Screws
Optional Components: |
|
| |
45o Elbow - | AstroCap | ||
| and 4" Aluminum Vent | Vinyl Siding Standoff (AstroCap) | |
Vinyl Siding Shield for Riser Vent | Vent Guard (AstroCap) | ||
| Terminal |
|
|
Vent Guard (Riser Vent Terminal) |
|
| |
940 | Square Wall Thimble Cover* |
|
|
981Snorkel Termination (36")*
982Snorkel Termination (14")*
942 Wall Penetration
Heat Shield*
* Simpson