Hampton Direct H15-NG1, H15-LP1 On a siding cov- ered wall, a vinyl siding standoff

Page 20

INSTALLATION

3)Attach the 4" dia. fl ex liner to the vent ter- minal ensuring that the fl ex overlaps the collar of the vent terminal by a minimum of 1-3/8"(35mm). Use Mill-Pac to seal and secure with 3 of the #8 x 1/2" screws (stainless steel).

4)Attach the adjustable pipe section to the vent terminal using Mill-Pac and/or high temperature silicone and attach with 3 of the #8 x 1/2" screws (stainless steel).

NOTE: For best results and optimum per- formance with each approved vent- ingsystem,itishighlyrecommended toapply“Mill-Pac”sealant(supplied) to every inner pipe connection. Fail- ure to do so may result in drafting or performance issues not covered under warranty. Silicone (red RTV) is optional.

Note: The pipe seam should be fac- ing down.

Note: To make the installation more aes- thetically pleasing, we recommend framing out a square that the cap can be mounted on.

Note: If installing termination

on a siding cov- ered wall, a vinyl siding standoff

or furring strips must be used to ensure that the termination is not recessed into the siding. For vinyl siding standoff

installation refer to the Dura-Vent Termination instructions.

5)Slide the partially connected pipe and vent terminal assembly through the wall thimbles (from the exterior into the interior) and secure the cap to the exterior wall with 4 of the supplied screws (#8 x 1-1/2" drill point, stainless steel). Note: pilot holes will need to be drilled through the wall thimble on all 4 corners.

Note: The four screws provided for the vent cap should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

6)A bead of non-hardening mastic should be run around both the termination and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff.

7)Stretch the 4" dia. fl ex liner out fully and get a trial fi t of the liner onto the 4" dia. starter collar.

8)Cut the 4" dia. fl ex liner to the desired size. Hint: leave an extra 12" to 16" of length, this will make the fi nal assembly easier to work with.

9)Secure the 4" dia. fl ex liner to the 4" adapter with Mill-Pac and 3 of the #8 x 1/2" screws (stainless steel).

10)Slide the decorativeThimble Cover over the pipe sections and secure with 4 screws (#8 x 1-1/2" drill point, black) to the wall.

11)Slide the 90o elbow (crimp end up), the 45o elbow and the 4 ft. pipe section (crimp end up) over the 4" dia. fl ex liner.

12)Install the spring spacers onto the pipe sections.

13)Secure the 4" dia. fl ex liner with adapter onto the stove collar. Put a bead of Mill-Pac around the appliance adapter and secure with 3 screws (#8 x 1/2, stainless steel).

14)Attach the 45o elbow onto the starter col- lar by sealing with Mill-Pac and/or high temperature silicone and securing with 3 of the #8 x 1/2" (black) screws.

15)Attach the pipe section to the 45o elbow by sealing with Mill-Pac and/or high tempera- ture silicone and securing with 3 of the #8 x 1/2" screws (black). Pipe seams should be facing the wall.

16)Attach the 90o elbow onto the pipe section by sealing with Mill-Pac and/or high tem- perature silicone and securing with 3 of the #8 x 1/2" screws (black).

17)Slide the adjustable pipe section onto the 90o elbow. Slide the trim collar over the adjustable pipe sections to cover the joint of the telescopic section.) The fl ex may have to be compressed back in order for the adjustable pipe to properly mate to the elbow. Seal with Mill-Pac and/or high temperature silicone and secure with 3 of the #8 x 1/2" screws (black). Pipe seams facing down.

18)Install the trim collar over the starter col- lar and secure with a #8 x 1/2" screw (black).

If the pipe needs to be touched up, use only Stove Brite High Temperature Metallic Black Stove Paint.

20

Hampton® H15-1 Direct Vent Freestanding Gas Stove

Image 20
Contents H15 Direct Vent Gas Fireplace 918-516a 12/17/07To the New Owner Unit DimensionsHampton Table of Contents Safety Label Requirements MA Code CO DetectorInstallation SpecificationsImportant Message Save These Instructions Mobile Manufactured Homes After First SaleGeneral Safety Information Installation ChecklistClearances to Combustibles This includesInstallation Optional FANManufactured Mobile Home Additional Requirements Fan Kit ContainsWires Lug Nut Rear PlatePrecautions Vent Restrictor PositionRotating Elbow Remove all 4 screws WashersExterior Vent Terminal Locations 6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Rigid Pipe Venting Systems AlternateHorizontal CapsHorizontal Venting with Two 2 90o Elbows + H1 With these options, maxFeet total horizontal Vertical Venting with Two 2 90o ElbowsMin Max Min. pipe length is 30 feet with min Venting Arrangements Vertical Termination with CO-LINEAR Flex System Required PartsStraight Vertical Terminations DescriptionDV Stove Horizontal Vent KIT Qty. DescriptionOn a siding cov- ered wall, a vinyl siding standoff Planning Your Venting Installation Minimum components for a Horizontal InstallationKit #640-944 Kit #380-946 640-545/P Decorative Wall Trim Black Tube Mill-Pac ScrewsPlanning Your Dura-Vent Installation DURA-VENT Termination KITDura-Vent Basic Horizontal Kit # 90o Elbow Wall Thimble Cover Horiz. Sq. Term. CapBelow Grade Snorkel Installation Horizontal TerminationsMinimum components for a Dura-Vent Verti- cal Termination Snorkel TerminationsVertical Terminations Seal around the outer edge of the Riser Vent Backing PlateOffset Chart Continue to assemble pipe lengthsConverting a Factory Built Metal Chimney Approved for US Installations OnlyVent System GAS Connection Cathedral CeilingsHigh Elevation Valve Description Conversion KIT# 381-969 from NG to LP LPG Conversion Kit Contains QtyInstallation of the DC Sparker Velcro LOG SET Installation Inside ViewRemove Glass Door Left Front Log Right Front LogLogs must be oriented as shown below Wire Size Max. Length Connect the wires as per the wiring diagram belowFinal Check Check for proper draftWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsMaintenance Maintenance InstructionsPilot Adjustment Normal Operating Sounds of GAS AppliancesGeneral Vent Maintenance Glass ReplacementFAN Maintenance LOG ReplacementInstalling Valve Assembly To remove valve from valve assembly, continueRemoving Valve ScrewsParts List Main AssemblyBurner & LOG Assembly 910-039Hampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information

H15-LP1, H15-NG1 specifications

Hampton Direct has established a reputation for producing innovative and high-quality products, and their H15-NG1 and H15-LP1 appliances are no exceptions. These two models have been thoughtfully designed to cater to different needs while sharing several essential features that promise reliability and performance.

The H15-NG1 is designed as a natural gas appliance, ideal for users who prefer the efficiency and cost-effectiveness of natural gas heating. Its advanced technology ensures that it operates smoothly and efficiently, providing consistent heating without compromising safety. Users can appreciate the integrated safety features, including automated shut-off mechanisms and flame detection systems. The H15-NG1 also has adjustable heat settings, giving users the flexibility to control the temperature according to their requirements.

On the other hand, the H15-LP1 is specifically designed for propane users. This model is perfect for those who utilize propane as a primary energy source in their households. Similar to its counterpart, the H15-LP1 boasts a powerful heating system that can quickly warm up large spaces, making it an excellent choice for both indoor and outdoor applications. It also includes safety features such as a pressure regulator, ensuring a stable flow of propane that enhances both efficiency and safety.

Both the H15-NG1 and H15-LP1 are constructed with durable materials, ensuring longevity and resilience in various conditions. They are easy to install and user-friendly, making them suitable for users of all experience levels.

Another significant feature of both models is their energy efficiency, which not only provides savings on utility bills but also contributes to an eco-friendly lifestyle. They are equipped with innovative heating technology that maximizes heat output while minimizing energy consumption. This focus on sustainability aligns with contemporary standards for energy-efficient home appliances.

In summary, the Hampton Direct H15-NG1 and H15-LP1 offer impressive features and technologies designed to meet diverse heating needs. With a commitment to safety, efficiency, and user convenience, these models stand out as reliable choices for homeowners looking for effective heating solutions. Whether you prefer natural gas or propane, both units promise a blend of performance, durability, and ease of use.