MAINTENANCE

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These com- ponents should be replaced immediately.

2)Remove the Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or other foreign material.

3)Checkforevidencesofexcessivecondensa- tion, such as water droplets forming in the innerliner,andsubsequentlydrippingoutthe joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive lateral runs, toomanyelbows,andexteriorportionsofthe system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fi ttings have been disturbed, and conse- quently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

5)Verify proper operation after servicing.

GLASS REPLACEMENT

Your stove is supplied with high temperature, 5

mmNeoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement door from an au- thorized Hampton® dealer only, and follow our step-by-step instructions for replacement.

1)Lift off Cast Top.

2)Open the 2 latches to remove Glass Front. Angle out and then lift, same as Cast Front.

FAN MAINTENANCE

Ifyourfanrequiresmaintenanceorreplacement, access to the fan is through the rear access panel on the back of the unit.

IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming out the fan squirrel cages, around the motor, and around the grills on the back of the stove.

WARNING:

Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into

aproperly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

IMPORTANT

Disconnect power supply

before servicing

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under warranty.

Latches

3)Remove glass and replace with new glass.

4)Re-install Cast Top.

WARNING:Donotoperateappliance with glass panel removed, cracked orbroken.Replacementoftheglass should be done by a licensed or qualified service person.

Note: Wearing gloves will protect your hands while handling glass.

40

Hampton® H15-1 Direct Vent Freestanding Gas Stove

Image 40
Contents H15 Direct Vent Gas Fireplace 918-516a 12/17/07Hampton Unit DimensionsTo the New Owner Table of Contents Safety Label Requirements MA Code CO DetectorInstallation SpecificationsImportant Message Save These Instructions Mobile Manufactured Homes After First SaleGeneral Safety Information Installation ChecklistClearances to Combustibles This includesInstallation Optional FANManufactured Mobile Home Additional Requirements Fan Kit ContainsWires Lug Nut Rear PlatePrecautions Vent Restrictor PositionRotating Elbow Remove all 4 screws WashersExterior Vent Terminal Locations 6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Rigid Pipe Venting Systems AlternateHorizontal CapsHorizontal Venting with Two 2 90o Elbows + H1 With these options, maxMin Max Min. pipe length is 30 feet with min Vertical Venting with Two 2 90o ElbowsFeet total horizontal Venting Arrangements Vertical Termination with CO-LINEAR Flex System Required PartsStraight Vertical Terminations DescriptionDV Stove Horizontal Vent KIT Qty. DescriptionOn a siding cov- ered wall, a vinyl siding standoff Planning Your Venting Installation Minimum components for a Horizontal InstallationKit #640-944 Kit #380-946 640-545/P Decorative Wall Trim Black Tube Mill-Pac ScrewsPlanning Your Dura-Vent Installation DURA-VENT Termination KITDura-Vent Basic Horizontal Kit # 90o Elbow Wall Thimble Cover Horiz. Sq. Term. CapBelow Grade Snorkel Installation Horizontal TerminationsMinimum components for a Dura-Vent Verti- cal Termination Snorkel TerminationsVertical Terminations Seal around the outer edge of the Riser Vent Backing PlateOffset Chart Continue to assemble pipe lengthsVent System Approved for US Installations OnlyConverting a Factory Built Metal Chimney High Elevation Cathedral CeilingsGAS Connection Valve Description Conversion KIT# 381-969 from NG to LP LPG Conversion Kit Contains QtyInstallation of the DC Sparker Velcro LOG SET Installation Inside ViewRemove Glass Door Left Front Log Right Front LogLogs must be oriented as shown below Wire Size Max. Length Connect the wires as per the wiring diagram belowFinal Check Check for proper draftWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsMaintenance Maintenance InstructionsPilot Adjustment Normal Operating Sounds of GAS AppliancesGeneral Vent Maintenance Glass ReplacementFAN Maintenance LOG ReplacementInstalling Valve Assembly To remove valve from valve assembly, continueRemoving Valve ScrewsParts List Main AssemblyBurner & LOG Assembly 910-039Hampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information

H15-LP1, H15-NG1 specifications

Hampton Direct has established a reputation for producing innovative and high-quality products, and their H15-NG1 and H15-LP1 appliances are no exceptions. These two models have been thoughtfully designed to cater to different needs while sharing several essential features that promise reliability and performance.

The H15-NG1 is designed as a natural gas appliance, ideal for users who prefer the efficiency and cost-effectiveness of natural gas heating. Its advanced technology ensures that it operates smoothly and efficiently, providing consistent heating without compromising safety. Users can appreciate the integrated safety features, including automated shut-off mechanisms and flame detection systems. The H15-NG1 also has adjustable heat settings, giving users the flexibility to control the temperature according to their requirements.

On the other hand, the H15-LP1 is specifically designed for propane users. This model is perfect for those who utilize propane as a primary energy source in their households. Similar to its counterpart, the H15-LP1 boasts a powerful heating system that can quickly warm up large spaces, making it an excellent choice for both indoor and outdoor applications. It also includes safety features such as a pressure regulator, ensuring a stable flow of propane that enhances both efficiency and safety.

Both the H15-NG1 and H15-LP1 are constructed with durable materials, ensuring longevity and resilience in various conditions. They are easy to install and user-friendly, making them suitable for users of all experience levels.

Another significant feature of both models is their energy efficiency, which not only provides savings on utility bills but also contributes to an eco-friendly lifestyle. They are equipped with innovative heating technology that maximizes heat output while minimizing energy consumption. This focus on sustainability aligns with contemporary standards for energy-efficient home appliances.

In summary, the Hampton Direct H15-NG1 and H15-LP1 offer impressive features and technologies designed to meet diverse heating needs. With a commitment to safety, efficiency, and user convenience, these models stand out as reliable choices for homeowners looking for effective heating solutions. Whether you prefer natural gas or propane, both units promise a blend of performance, durability, and ease of use.