Hampton Direct H15-LP1, H15-NG1 installation manual DV Stove Horizontal Vent KIT, Qty. Description

Page 19

INSTALLATION

DV STOVE HORIZONTAL VENT KIT

DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed to install the H15-1 Direct Vent unit with up & out horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown in the "Dura-Vent Termina- tion Kit" and "Dura-Vent Venting Components" sections.

Qty. Description

1)1 Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length,

 

 

Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm)

 

 

inside diameter

2)

1

Flex Liner, compressed aluminium 2 ply liner, 4" (102mm)

 

 

inside diameter

3)

4

spring spacers

4)

1

90 deg. Elbow

5)

1

Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2 pcs.

6)

1

Thimble Cover

7)

1

Wall Thimble (2 pcs.)

8)

1

Adapter

9)

1

AstroCap Termination Cap

10)

2

Trim Collars

11)

1

tube of Mill-Pac, high temperature sealant

12)

12

Screws, #8 x 1/2" Self tapping, Stainless Steel

13)14 Screws, #8 x 1/2" Self tapping, Black

14) 4 Screws #8 x 1-1/2" Drill Point, Black

15) 4 Screws #8 x 1-1/2" Drill Point, Stainless Steel

16) 8 Wood screws #8 x 1"

Note:

a)Liner sections should be con- tinuous without any joints or seams.

b)This is an approved system, therefore components in this system must not be substituted for any other manufacturer's products.

DV STOVE HORIZONTAL VENT KIT (#946-116 & #946-216) INSTALLATION

Review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wall thick- ness. Refer to the "Exterior Vent Terminal

Locations"and"RigidPipeVentingSystems" sections for vent location and clearance dimensions, and the "Vent Restrictor Posi- tion" for the correct positioning.

1)Set the unit in its desired location. Check to determine if wall studs will be in the way of the venting system, adjust location until all clearances are met and there are no obstructions.

Note: A1-1/2"(38mm) clearance around the outerpipemustbemaintainedexcept that only a 1" (25mm) clearance is needed at the termination end.

IMPORTANT:

Do not locate termination hood where excessive snow or ice buildupmayoccur.Besuretocheck vent termination area after snow falls,andcleartopreventaccidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

2)Assemble a trial fit to determine the vertical center-line for the vent termination.

a)Cut a 9-1/2" x 9-1/2" (241mm x 241

mm)square hole on both the interior and exterior wall.

b)Install wall thimbles on both interior and exterior wall with 4 wood screws (#8 x 1") per thimble.

c)Attach the 2 piece adjustable pipe sec- tion to the vent terminal and slide into position from the exterior. The larger diameter end of the adjustable pipe goes to the vent terminal.

d)Install the 90o elbow onto the adjust- able pipe to determine the vertical centerline.

Note:ifthecenterlinecannotbemet, the adjustable sections will have to be cut.

e)Cut the 4 ft. section of rigid pipe to length.Attach the 45o elbow to the rigid pipe, and ensure that the pipe length when cut (with the 45o elbow) will seat onto both the starter collar and the 90o elbow. Crimped section of rigid pipe seats into the 90o elbow. Only cut the uncrimped side of pipe.

Dismantle all pipe sections including vent terminal.

Hampton® H15-1 Direct Vent Freestanding Gas Stove

19

Image 19
Contents 918-516a 12/17/07 H15 Direct Vent Gas FireplaceHampton Unit DimensionsTo the New Owner Table of Contents Safety Label MA Code CO Detector RequirementsMobile Manufactured Homes After First Sale InstallationSpecifications Important Message Save These InstructionsThis includes General Safety InformationInstallation Checklist Clearances to CombustiblesFan Kit Contains InstallationOptional FAN Manufactured Mobile Home Additional RequirementsRear Plate Wires Lug NutRemove all 4 screws Washers PrecautionsVent Restrictor Position Rotating ElbowExterior Vent Terminal Locations Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Caps Rigid Pipe Venting SystemsAlternate Horizontal+ H1 With these options, max Horizontal Venting with Two 2 90o ElbowsMin Max Min. pipe length is 30 feet with min Vertical Venting with Two 2 90o ElbowsFeet total horizontal Venting Arrangements Description Vertical Termination with CO-LINEAR Flex SystemRequired Parts Straight Vertical TerminationsQty. Description DV Stove Horizontal Vent KITOn a siding cov- ered wall, a vinyl siding standoff 640-545/P Decorative Wall Trim Black Tube Mill-Pac Screws Planning Your Venting InstallationMinimum components for a Horizontal Installation Kit #640-944 Kit #380-94690o Elbow Wall Thimble Cover Horiz. Sq. Term. Cap Planning Your Dura-Vent InstallationDURA-VENT Termination KIT Dura-Vent Basic Horizontal Kit #Snorkel Terminations Below Grade Snorkel InstallationHorizontal Terminations Minimum components for a Dura-Vent Verti- cal TerminationSeal around the outer edge of the Riser Vent Backing Plate Vertical TerminationsContinue to assemble pipe lengths Offset ChartVent System Approved for US Installations OnlyConverting a Factory Built Metal Chimney High Elevation Cathedral CeilingsGAS Connection Valve Description LPG Conversion Kit Contains Qty Conversion KIT# 381-969 from NG to LPInstallation of the DC Sparker Velcro Left Front Log Right Front Log LOG SET InstallationInside View Remove Glass DoorLogs must be oriented as shown below Check for proper draft Wire Size Max. LengthConnect the wires as per the wiring diagram below Final CheckWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingNormal Operating Sounds of GAS Appliances MaintenanceMaintenance Instructions Pilot AdjustmentLOG Replacement General Vent MaintenanceGlass Replacement FAN MaintenanceScrews Installing Valve AssemblyTo remove valve from valve assembly, continue Removing ValveMain Assembly Parts List910-039 Burner & LOG AssemblyHampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

H15-LP1, H15-NG1 specifications

Hampton Direct has established a reputation for producing innovative and high-quality products, and their H15-NG1 and H15-LP1 appliances are no exceptions. These two models have been thoughtfully designed to cater to different needs while sharing several essential features that promise reliability and performance.

The H15-NG1 is designed as a natural gas appliance, ideal for users who prefer the efficiency and cost-effectiveness of natural gas heating. Its advanced technology ensures that it operates smoothly and efficiently, providing consistent heating without compromising safety. Users can appreciate the integrated safety features, including automated shut-off mechanisms and flame detection systems. The H15-NG1 also has adjustable heat settings, giving users the flexibility to control the temperature according to their requirements.

On the other hand, the H15-LP1 is specifically designed for propane users. This model is perfect for those who utilize propane as a primary energy source in their households. Similar to its counterpart, the H15-LP1 boasts a powerful heating system that can quickly warm up large spaces, making it an excellent choice for both indoor and outdoor applications. It also includes safety features such as a pressure regulator, ensuring a stable flow of propane that enhances both efficiency and safety.

Both the H15-NG1 and H15-LP1 are constructed with durable materials, ensuring longevity and resilience in various conditions. They are easy to install and user-friendly, making them suitable for users of all experience levels.

Another significant feature of both models is their energy efficiency, which not only provides savings on utility bills but also contributes to an eco-friendly lifestyle. They are equipped with innovative heating technology that maximizes heat output while minimizing energy consumption. This focus on sustainability aligns with contemporary standards for energy-efficient home appliances.

In summary, the Hampton Direct H15-NG1 and H15-LP1 offer impressive features and technologies designed to meet diverse heating needs. With a commitment to safety, efficiency, and user convenience, these models stand out as reliable choices for homeowners looking for effective heating solutions. Whether you prefer natural gas or propane, both units promise a blend of performance, durability, and ease of use.