INSTALLATION
Horizontal Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
Option |
| V | H + H1 |
A) | 1' | Min. | 3' Max. |
B) | 2' | Min. | 4' Max. |
C) | 3' | Min. | 5' Max. |
D) | 4' | Min. | 6' Max. |
E) | 5' | Min. | 7' Max. |
F) | 6' | Min. | 8' Max. |
With these options, maxi- mum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal.
Please note minimum 1 foot between 90o elbows is required.
H1
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the "Vent Restrictor Postion" section.
V
H
Horizontal Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
Option | H | V | H + H1 With these options, max. |
A)1' Max. 1' Min. 3' Max. total pipe length is 30 feet
B)2' Max. 2' Min. 5' Max. with min. of 8 feet total vertical and max. 8 feet
C)3' Max. 4' Min. 6' Max. total horizontal.
D)4' Max. 6' Min. 7' Max. Please note min. 1 foot
E)5' Max. 8' Min. 8' Max. between 90o elbows is required.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the "Vent |
|
Restrictor Postion" section. | H1 |
|
H
V