Hampton Direct H15-LP1, H15-NG1 installation manual Offset Chart, Continue to assemble pipe lengths

Page 25

INSTALLATION

Diagram 8

3)To install the Round Support Box/Wall Thim- ble in a fl at ceiling, cut a 10 inch square hole in the ceiling centred on the hole drilled in Step 2. Frame the hole as shown in diagram 9.

Diagram 9

4)Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Round Support Box. Insure that all pipes and elbow connections are in the fully twist-locked position and sealed.

Diagram 10: The upper half of the fl ashing is installed under the roofi ng material and not nailed down until the chimney is installed. This allows for small adjustments.

Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet, to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose. See diagram 5.

Galvanizedpipeandelbowsmaybeutilized in the attic as well as above the roofl ine. The galvanized fi nish is desirable above the roofl ine due to its higher corrosion resistance.

Continue to add pipe sections through the

ashing until the height of the vent cap meets the minimum height requirements specifi ed in diagram 11 or local codes. Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem.

7)Ensure vent is vertical and secure the base of the fl ashing to the roof with roofi ng rails, slide storm collar over the pipe section and seal with a mastic.

8)Install the vertical termination cap by twist locking it.

Notes:

a)For multistorey vertical installations, a Ceiling Fire stop (Part # 963) is required at the second floor, and any subsequent fl oor. Diagram 12. The opening should be framed to 10 " x 10" inside dimen- sions, in the same manner as shown in diagram 9.

b)Any occupied areas above the first floor, including closets and storage spaces, through which the vertical vent passes, must be enclosed.

Diagram 12

Note: For best results and optimum performance with each approved venting system, it is highly recom- mended to apply “Mill-Pac” sealant (supplied) to every inner pipe con- nection. Failure to do so may result in drafting or performance issues notcoveredunderwarranty.Silicone (red RTV) is optional.

5)Cut a hole in the roof centred on the small drilled hole placed in the roof in Step 2. The hole should be of suffi cient size to meet the minimum requirements for clearance to combustibles of 1-1/4". Slip the fl ashing under the shingles (shingles should overlap half the fl ashing) as per diagram 10.

6)Continue to assemble pipe lengths.

Diagram 11

Roof Pitch

Minimum Vent Height

 

Feet

Meters

fl at to 7/12

2

0.61

over 7/12 to 8/12

2

0.61

over 8/12 to 9/12

2

0.61

over 9/12 to 10/12

2.5

0.76

over 10/12 to 11/12

3.25

0.99

over 11/12 to 12/12

4

1.22

over 12/12 to 14/12

5

1.52

over 14/12 to 16/12

6

1.83

over 16/12 to 18/12

7

2.13

over 18/12 to 20/12

7.5

2.29

over 20/12 to 21/12

8

2.44

 

 

 

Offset Chart

Hampton® H15-1 Direct Vent Freestanding Gas Stove

25

Image 25
Contents 918-516a 12/17/07 H15 Direct Vent Gas FireplaceHampton Unit DimensionsTo the New Owner Table of Contents Safety Label MA Code CO Detector RequirementsSpecifications InstallationImportant Message Save These Instructions Mobile Manufactured Homes After First SaleInstallation Checklist General Safety InformationClearances to Combustibles This includesOptional FAN InstallationManufactured Mobile Home Additional Requirements Fan Kit ContainsRear Plate Wires Lug NutVent Restrictor Position PrecautionsRotating Elbow Remove all 4 screws WashersExterior Vent Terminal Locations Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Alternate Rigid Pipe Venting SystemsHorizontal Caps+ H1 With these options, max Horizontal Venting with Two 2 90o ElbowsMin Max Min. pipe length is 30 feet with min Vertical Venting with Two 2 90o ElbowsFeet total horizontal Venting Arrangements Required Parts Vertical Termination with CO-LINEAR Flex SystemStraight Vertical Terminations DescriptionQty. Description DV Stove Horizontal Vent KITOn a siding cov- ered wall, a vinyl siding standoff Minimum components for a Horizontal Installation Planning Your Venting InstallationKit #640-944 Kit #380-946 640-545/P Decorative Wall Trim Black Tube Mill-Pac Screws DURA-VENT Termination KIT Planning Your Dura-Vent Installation Dura-Vent Basic Horizontal Kit # 90o Elbow Wall Thimble Cover Horiz. Sq. Term. CapHorizontal Terminations Below Grade Snorkel InstallationMinimum components for a Dura-Vent Verti- cal Termination Snorkel TerminationsSeal around the outer edge of the Riser Vent Backing Plate Vertical TerminationsContinue to assemble pipe lengths Offset ChartVent System Approved for US Installations OnlyConverting a Factory Built Metal Chimney High Elevation Cathedral CeilingsGAS Connection Valve Description LPG Conversion Kit Contains Qty Conversion KIT# 381-969 from NG to LPInstallation of the DC Sparker Velcro Inside View LOG SET InstallationRemove Glass Door Left Front Log Right Front LogLogs must be oriented as shown below Connect the wires as per the wiring diagram below Wire Size Max. LengthFinal Check Check for proper draftWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingMaintenance Instructions MaintenancePilot Adjustment Normal Operating Sounds of GAS AppliancesGlass Replacement General Vent MaintenanceFAN Maintenance LOG ReplacementTo remove valve from valve assembly, continue Installing Valve AssemblyRemoving Valve ScrewsMain Assembly Parts List910-039 Burner & LOG AssemblyHampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information