Hampton Direct H15-LP1, H15-NG1 installation manual Offset Chart, Continue to assemble pipe lengths

Page 25

INSTALLATION

Diagram 8

3)To install the Round Support Box/Wall Thim- ble in a fl at ceiling, cut a 10 inch square hole in the ceiling centred on the hole drilled in Step 2. Frame the hole as shown in diagram 9.

Diagram 9

4)Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Round Support Box. Insure that all pipes and elbow connections are in the fully twist-locked position and sealed.

Diagram 10: The upper half of the fl ashing is installed under the roofi ng material and not nailed down until the chimney is installed. This allows for small adjustments.

Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet, to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose. See diagram 5.

Galvanizedpipeandelbowsmaybeutilized in the attic as well as above the roofl ine. The galvanized fi nish is desirable above the roofl ine due to its higher corrosion resistance.

Continue to add pipe sections through the

ashing until the height of the vent cap meets the minimum height requirements specifi ed in diagram 11 or local codes. Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem.

7)Ensure vent is vertical and secure the base of the fl ashing to the roof with roofi ng rails, slide storm collar over the pipe section and seal with a mastic.

8)Install the vertical termination cap by twist locking it.

Notes:

a)For multistorey vertical installations, a Ceiling Fire stop (Part # 963) is required at the second floor, and any subsequent fl oor. Diagram 12. The opening should be framed to 10 " x 10" inside dimen- sions, in the same manner as shown in diagram 9.

b)Any occupied areas above the first floor, including closets and storage spaces, through which the vertical vent passes, must be enclosed.

Diagram 12

Note: For best results and optimum performance with each approved venting system, it is highly recom- mended to apply “Mill-Pac” sealant (supplied) to every inner pipe con- nection. Failure to do so may result in drafting or performance issues notcoveredunderwarranty.Silicone (red RTV) is optional.

5)Cut a hole in the roof centred on the small drilled hole placed in the roof in Step 2. The hole should be of suffi cient size to meet the minimum requirements for clearance to combustibles of 1-1/4". Slip the fl ashing under the shingles (shingles should overlap half the fl ashing) as per diagram 10.

6)Continue to assemble pipe lengths.

Diagram 11

Roof Pitch

Minimum Vent Height

 

Feet

Meters

fl at to 7/12

2

0.61

over 7/12 to 8/12

2

0.61

over 8/12 to 9/12

2

0.61

over 9/12 to 10/12

2.5

0.76

over 10/12 to 11/12

3.25

0.99

over 11/12 to 12/12

4

1.22

over 12/12 to 14/12

5

1.52

over 14/12 to 16/12

6

1.83

over 16/12 to 18/12

7

2.13

over 18/12 to 20/12

7.5

2.29

over 20/12 to 21/12

8

2.44

 

 

 

Offset Chart

Hampton® H15-1 Direct Vent Freestanding Gas Stove

25

Image 25
Contents 918-516a 12/17/07 H15 Direct Vent Gas FireplaceHampton Unit DimensionsTo the New Owner Table of Contents Safety Label MA Code CO Detector RequirementsSpecifications InstallationImportant Message Save These Instructions Mobile Manufactured Homes After First SaleInstallation Checklist General Safety InformationClearances to Combustibles This includesOptional FAN InstallationManufactured Mobile Home Additional Requirements Fan Kit ContainsRear Plate Wires Lug NutVent Restrictor Position PrecautionsRotating Elbow Remove all 4 screws WashersExterior Vent Terminal Locations Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Alternate Rigid Pipe Venting SystemsHorizontal Caps+ H1 With these options, max Horizontal Venting with Two 2 90o ElbowsMin Max Min. pipe length is 30 feet with min Vertical Venting with Two 2 90o ElbowsFeet total horizontal Venting Arrangements Required Parts Vertical Termination with CO-LINEAR Flex SystemStraight Vertical Terminations DescriptionQty. Description DV Stove Horizontal Vent KITOn a siding cov- ered wall, a vinyl siding standoff Minimum components for a Horizontal Installation Planning Your Venting InstallationKit #640-944 Kit #380-946 640-545/P Decorative Wall Trim Black Tube Mill-Pac ScrewsDURA-VENT Termination KIT Planning Your Dura-Vent InstallationDura-Vent Basic Horizontal Kit # 90o Elbow Wall Thimble Cover Horiz. Sq. Term. CapHorizontal Terminations Below Grade Snorkel InstallationMinimum components for a Dura-Vent Verti- cal Termination Snorkel TerminationsSeal around the outer edge of the Riser Vent Backing Plate Vertical TerminationsContinue to assemble pipe lengths Offset ChartVent System Approved for US Installations OnlyConverting a Factory Built Metal Chimney High Elevation Cathedral CeilingsGAS Connection Valve Description LPG Conversion Kit Contains Qty Conversion KIT# 381-969 from NG to LPInstallation of the DC Sparker Velcro Inside View LOG SET InstallationRemove Glass Door Left Front Log Right Front LogLogs must be oriented as shown below Connect the wires as per the wiring diagram below Wire Size Max. LengthFinal Check Check for proper draftWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingMaintenance Instructions MaintenancePilot Adjustment Normal Operating Sounds of GAS AppliancesGlass Replacement General Vent MaintenanceFAN Maintenance LOG ReplacementTo remove valve from valve assembly, continue Installing Valve AssemblyRemoving Valve ScrewsMain Assembly Parts List910-039 Burner & LOG AssemblyHampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

H15-LP1, H15-NG1 specifications

Hampton Direct has established a reputation for producing innovative and high-quality products, and their H15-NG1 and H15-LP1 appliances are no exceptions. These two models have been thoughtfully designed to cater to different needs while sharing several essential features that promise reliability and performance.

The H15-NG1 is designed as a natural gas appliance, ideal for users who prefer the efficiency and cost-effectiveness of natural gas heating. Its advanced technology ensures that it operates smoothly and efficiently, providing consistent heating without compromising safety. Users can appreciate the integrated safety features, including automated shut-off mechanisms and flame detection systems. The H15-NG1 also has adjustable heat settings, giving users the flexibility to control the temperature according to their requirements.

On the other hand, the H15-LP1 is specifically designed for propane users. This model is perfect for those who utilize propane as a primary energy source in their households. Similar to its counterpart, the H15-LP1 boasts a powerful heating system that can quickly warm up large spaces, making it an excellent choice for both indoor and outdoor applications. It also includes safety features such as a pressure regulator, ensuring a stable flow of propane that enhances both efficiency and safety.

Both the H15-NG1 and H15-LP1 are constructed with durable materials, ensuring longevity and resilience in various conditions. They are easy to install and user-friendly, making them suitable for users of all experience levels.

Another significant feature of both models is their energy efficiency, which not only provides savings on utility bills but also contributes to an eco-friendly lifestyle. They are equipped with innovative heating technology that maximizes heat output while minimizing energy consumption. This focus on sustainability aligns with contemporary standards for energy-efficient home appliances.

In summary, the Hampton Direct H15-NG1 and H15-LP1 offer impressive features and technologies designed to meet diverse heating needs. With a commitment to safety, efficiency, and user convenience, these models stand out as reliable choices for homeowners looking for effective heating solutions. Whether you prefer natural gas or propane, both units promise a blend of performance, durability, and ease of use.