Hampton Direct H15-LP1, H15-NG1 installation manual 6-5/8 Rigid Pipe Cross Reference Chart

Page 13

INSTALLATION

4” x 6-5/8” Rigid Pipe Cross Reference Chart (Cont.)

Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.

Description

Simpson

Simpson

Selkirk

American Metal

Metal-Fab®

Security

Direct Vent GS®

Products

®

Direct Vent Pro®

Discontinued

Direct-Temp™

 

Sure Seal

Secure Vent®

 

 

 

Amerivent Direct

 

 

Attic Insulation Shield 12”

46DVA-IS - N/A from FPI

N/A

N/A

4DAIS12

 

N/A

SV4RSA

Attic Insulation Shield - Cold Climates 36”

N/A

N/A

N/A

4DAIS36

 

N/A

N/A

Basic Horizontal Termination Kit (A)

Horizontal Termination Kit (B)

Vertical Termination Kit

DISC. 46DVA-KHA (Changed Components) DISC.

970

971

978

4DT-HKA

4DT-HKB

4DT-VKC

4DHTK2

4DHTK1

4DVTK

4DHTKA

4DHTKB

4DVTK

SV - SHK

SV - HK

SV - FK

High Wind Vertical Cap

High Wind Horizontal Cap

Horizontal Square Termination Cap

Vertical Termination Cap

Storm Collar

46DVA-VCH

46DVA-HC

Disc - See 46DVA-HC 46DVA-VC 46DVA-SC

991

985

984

980

953

N/A

N/A 4DT-HHC 4DT-HVC 4DT-SC

N/A

N/A

4DHC

4DVC

4DSC

N/A

N/A

4DHT

4DVT

4DSC

N/A

N/A SV4CHC-1 SV4CGV-1 SV4FC

Adjustable Flashing, 0/12-6/12 Adjustable Flashing, 6/12-12/12

46DVA-F6 46DVA-F12

943

943S

4DT-AF6 4DT-AF12

4DF

4DF12

4DF 4DF-12

SV4FA

SV4FB

Vinyl Siding Standoff Vinyl Siding Shield Plate

46DVA-VSS N/A

950

N/A

4DT-VS 4DT-VSP

N/A

N/A

4DVS

N/A

SV4VS

SV4VS

Snorkel Termination 14” Snorkel Termination 36”

46DVA-SNK14 N/A

982

981

4DT-ST14 4DT-ST36

4D12S

4D36S

4DST14

4DST36

SV4STC14

SV4STC36

Restrictor Disk

Extended Vertical Termination Cap

Chimney Conversion Kit A

Chimney Conversion Kit B

Chimney Conversion Kit C

Chimney Conversion Kit Masonry

Mansonry Chimney Conversion Kit

(includes: Cap Adapter 18”x18” Flashing)

Wall Firestop

Colinear Flex Connectors

46DVA-RD 46DVA-VCE 46DVA-KCA 46DVA-KCB 46DVA-KCC 46DVA-KMC

46DVA-KCT

46DVA-WFS 46DVA-ADF

929

930

931

932

933

934

935

947

923F

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

FPI

946-506/P

Vent Guard (Optional) for AstropCap

946-205

Vinyl Siding Shield for Riser Vent Terminal

510-994

Rigid Pipe Adapter (Must use with all Rigid Piping)

946-208/P

Vent Guard (Optional) for Riser Vent Terminal

640-530/P

Riser Vent Terminal

946-523/P

AstroCap Horizontal Cap

 

 

946-206

Vinyl Siding Standoff for AstroCap

 

 

 

 

*NOTE: When using Metal-Fab Sure Seal Rigid Piping please note that either the Adaptor (4DDA) or 90º Starter Elbow (4D90A) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).

Offset Pipe Selection:

Use this table to determine offset pipe lengths.

Pipe Length

4” x 6-5/8” Venting

Run (X)

Rise (Y)

 

0”(0mm)

4-7/8”(124mm)

13-3/8”(340mm)

6”(152mm)

8”(203mm)

16-1/2”(419mm)

 

 

 

9”(229mm)

10-1/8”(257mm)

18-5/8”(473mm)

 

 

 

12”(305mm)

12-1/4”(311mm)

20-3/4”(527mm)

 

 

 

24”(610mm)

20-5/8”(524mm)

29-1/8”(740mm)

36”(914mm)

29”(737mm)

37-1/2”(953mm)

 

 

 

48”(1219mm)

37-7/16”(951mm)

45-15/16”(1167mm)

 

 

 

L

X

Y

For specifi c instructions or details on particular venting components please visit the following websites:

Simpson Direct Vent Pro: www.duravent.com

Selkirk Direct-Temp: www.selkirkcorp.com

American Metal Products Amerivent Direct: www.americanmetalproducts.com

Metal-Fab Sure Seal: www.mtlfab.com

Security Secure Vent: www.securitychimneys.com

NOTE: Horizontal runs of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present a possible fire hazard.

Hampton® H15-1 Direct Vent Freestanding Gas Stove

13

Image 13
Contents 918-516a 12/17/07 H15 Direct Vent Gas FireplaceHampton Unit DimensionsTo the New Owner Table of Contents Safety Label MA Code CO Detector RequirementsSpecifications InstallationImportant Message Save These Instructions Mobile Manufactured Homes After First SaleInstallation Checklist General Safety InformationClearances to Combustibles This includesOptional FAN InstallationManufactured Mobile Home Additional Requirements Fan Kit ContainsRear Plate Wires Lug NutVent Restrictor Position PrecautionsRotating Elbow Remove all 4 screws WashersExterior Vent Terminal Locations Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Alternate Rigid Pipe Venting SystemsHorizontal Caps+ H1 With these options, max Horizontal Venting with Two 2 90o ElbowsMin Max Min. pipe length is 30 feet with min Vertical Venting with Two 2 90o ElbowsFeet total horizontal Venting Arrangements Required Parts Vertical Termination with CO-LINEAR Flex SystemStraight Vertical Terminations DescriptionQty. Description DV Stove Horizontal Vent KITOn a siding cov- ered wall, a vinyl siding standoff Minimum components for a Horizontal Installation Planning Your Venting InstallationKit #640-944 Kit #380-946 640-545/P Decorative Wall Trim Black Tube Mill-Pac ScrewsDURA-VENT Termination KIT Planning Your Dura-Vent InstallationDura-Vent Basic Horizontal Kit # 90o Elbow Wall Thimble Cover Horiz. Sq. Term. CapHorizontal Terminations Below Grade Snorkel InstallationMinimum components for a Dura-Vent Verti- cal Termination Snorkel TerminationsSeal around the outer edge of the Riser Vent Backing Plate Vertical TerminationsContinue to assemble pipe lengths Offset ChartVent System Approved for US Installations OnlyConverting a Factory Built Metal Chimney High Elevation Cathedral CeilingsGAS Connection Valve Description LPG Conversion Kit Contains Qty Conversion KIT# 381-969 from NG to LPInstallation of the DC Sparker Velcro Inside View LOG SET InstallationRemove Glass Door Left Front Log Right Front LogLogs must be oriented as shown below Connect the wires as per the wiring diagram below Wire Size Max. LengthFinal Check Check for proper draftWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingMaintenance Instructions MaintenancePilot Adjustment Normal Operating Sounds of GAS AppliancesGlass Replacement General Vent MaintenanceFAN Maintenance LOG ReplacementTo remove valve from valve assembly, continue Installing Valve AssemblyRemoving Valve ScrewsMain Assembly Parts List910-039 Burner & LOG AssemblyHampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Hampton H15-1 Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

H15-LP1, H15-NG1 specifications

Hampton Direct has established a reputation for producing innovative and high-quality products, and their H15-NG1 and H15-LP1 appliances are no exceptions. These two models have been thoughtfully designed to cater to different needs while sharing several essential features that promise reliability and performance.

The H15-NG1 is designed as a natural gas appliance, ideal for users who prefer the efficiency and cost-effectiveness of natural gas heating. Its advanced technology ensures that it operates smoothly and efficiently, providing consistent heating without compromising safety. Users can appreciate the integrated safety features, including automated shut-off mechanisms and flame detection systems. The H15-NG1 also has adjustable heat settings, giving users the flexibility to control the temperature according to their requirements.

On the other hand, the H15-LP1 is specifically designed for propane users. This model is perfect for those who utilize propane as a primary energy source in their households. Similar to its counterpart, the H15-LP1 boasts a powerful heating system that can quickly warm up large spaces, making it an excellent choice for both indoor and outdoor applications. It also includes safety features such as a pressure regulator, ensuring a stable flow of propane that enhances both efficiency and safety.

Both the H15-NG1 and H15-LP1 are constructed with durable materials, ensuring longevity and resilience in various conditions. They are easy to install and user-friendly, making them suitable for users of all experience levels.

Another significant feature of both models is their energy efficiency, which not only provides savings on utility bills but also contributes to an eco-friendly lifestyle. They are equipped with innovative heating technology that maximizes heat output while minimizing energy consumption. This focus on sustainability aligns with contemporary standards for energy-efficient home appliances.

In summary, the Hampton Direct H15-NG1 and H15-LP1 offer impressive features and technologies designed to meet diverse heating needs. With a commitment to safety, efficiency, and user convenience, these models stand out as reliable choices for homeowners looking for effective heating solutions. Whether you prefer natural gas or propane, both units promise a blend of performance, durability, and ease of use.