INSTALLATION
The Becton gas stove is designed so that the flue can be fitted to either the top or the rear of the
appliance.
Fit the flue spigot and blanking plate for either top or rear flue outlet in accordance with figure 6a or 6b (below).
Lock the blanking plate in place by rotating anti- clockwise and tighten by tapping gently with a block of wood and mallet. Fit the spigot to the unused opening in the same way. The units are
sealed by the attached gaskets.
Fig 6c
REAR FLUE
Open Hearth
Fit and seal a ‘T’ section (with soot box) directly into the flue spigot. The maximum horizontal section allowed is 150mm.
Provide a minimum vertical height of 600mm of flue from the height of the rear flue outlet. See figure 7b.
Closure Plate
#Connect the flue spigot to the rear outlet. #Connect a flue extension to the spigot. #Fit the closure plate in fireplace.
#Position the fire so the flue extension passes through the hole in the closure plate.
#Ensure all joints are suitably sealed.
See Figure 7c.
TOP FLUE
Provide a minimum vertical height of 600mm of flue measured from the top of the appliance.
See Figure 7d.
Move the fire, with flue spigot in place, into position under the flue and seal the spigot/flue connection with fire cement. (Ref. Fig. 6c).
It is recommended that a smoke test is performed inside the fire to ensure that adequate flue draw is evident.
Fig 7a
12 | Becton Bunny & Becton 7 mk3 Gas stoves |