Aarrow Fires Becton 7 mk3 Introduction Important Notices, Statutory Requirements, Certification

Page 5

INTRODUCTION

IMPORTANT NOTICES

A qualified gas engineer must carry out the installation and servicing of this appliance in accordance with these instructions and in compliance with current Building Regulations.

Such person must be a registered CORGI engineer.

This appliance is designed to run on natural gas only. Warning - Only use the appliance with the specified gas.

The fire is fitted with a safety device to shut down the appliance if there is inadequate flue draw. If the fire shuts down for no apparent reason check chimney and air inlets to the room. In all cases the fire must not be re-lit until the safety aspects have been checked by a qualified gas engineer.

Please note the following;

The safety device must never be put out of action.

Sealed components must not be interfered with.

Servicing instructions and part identification numbers are given towards the back of the manual.

Only use genuine Aarrow parts for replacements.

Ventilation, purpose built ventilation is not normally required for either appliance, normal adventitious room ventilation being sufficient.

Coal Set, see safety notice on page 4.

All surfaces except the control knob, the control door handle and control door are considered to be working surfaces.

Warning: Under no circumstances must the fire be operated if the glass is cracked or broken.

Warning: If it is known or suspected that an operational or ignition fault exists on the appliance, it must not be used until it has been investigated and corrected by a qualified gas engineer.

Warning: THIS GAS APPLIANCE MUST BE SERVICED EVERY TWELVE MONTHS BY A QUALIFIED GAS ENGINEER.

STATUTORY REQUIREMENTS

The current Gas Safety (Installation and Use) Regulations (as amended).

The Building Regulations for England and Wales 2000 ref Approved Document J 2002 edition (issued by the DTLR).

The Building Standards (Scotland) (Consolidation) Regulations.

Detailed recommendations are outlined in the current issue of the following British Standards:- BS5440 parts 1 and 2, BS5871 part 1 and BS6891.

Any Manufacturer's Instructions must not be taken as overriding statutory requirements.

_________________________________________

CERTIFICATION

This appliance is CE certificated for performance and safety. Therefore, it is important that no alteration is made to the appliance.

Any alteration not approved by Aarrow Fires Ltd. will invalidate the guarantee.

Becton Bunny & Becton 7 mk3 Gas stoves

5

Image 5
Contents Becton MK Flaming Good Fires Installation ContentsGeneral Information Safety NoticesIntroduction Certification Introduction Important NoticesStatutory Requirements Fire Dimensions Operating Instructions Technical DataMax. Heat Setting Min. Heat SettingPositioning the rear lining Operating Instructions Fitting the Lining PanelsOperating Instructions Arranging the Coals Safety Notice Please see Safety Notices ref. Coal setOperating Instructions Lighting & Controlling the Fire Operating Instructions Fitting the Feet Installation Installing the FireFlue System Nacs National Association of Chimney Sweeps telephone 01785See d See cFire Location Graph 1.Combustible Shelf Clearances Test Sequence Installation Hearth RequirementsConnecting the GAS Supply Flame failure device testing Installation Fire TestingInstallation Check List ChecklistServicing Detail of Pilot Assembly Servicing Door Trim Fire Door Glass & Seal Replacement of the Door TrimEnsure the appliance is cold Lifting the door off its hingesRegular Service Servicing Burner AssemblyCleaning Outer Surfaces Servicing Annual ServiceCleaning the Glass See Safety Notices ref coal setServicing Fault DiagnosisAdd on Canopies Accessories and OptionsSpare Parts General Components Becton Bunny & Becton 7 mk3 Gas stoves Becton Bunny & Becton 7 mk3 Gas stoves Visual Aid Bunny Becton Part Description Spare PartsAFGS080 AFGS080 Control Door Handle Assembly AFGS1085AFGS025 Becton 7 mk3 Lining Kit AFGS1072Customer Registration GuaranteeDate of Visit Company Work Carried Out Signature Service RecordBecton Final Factory Check List ’ve checked it and it’s O.K