Aarrow Fires Becton 7 mk3, Becton Bunny Operating Instructions Lighting & Controlling the Fire

Page 9

OPERATING INSTRUCTIONS

LIGHTING & CONTROLLING THE FIRE

Under no circumstance must the fire be operated if the glass is cracked or broken.

Open the gas control access door situated at the bottom of the appliance. Always use the control door HANDLE.

Step 1a. To ignite the pilot push the control knob in, turn anti-clockwise towards the spark position and hold in for 15 seconds. (Fig 5a)

The pilot can be viewed through the L/H & centre front slots in the base matrix.

Fig 5a

Step 1b. Keep the control knob pressed in and turn

anti-clockwise to the pilot position. (Fig 5b)

Fig 5b

Step 1c. Keep the control knob pressed in for a further 15 seconds and then release. The pilot will remain alight.

If pilot does not remain alight repeat this procedure.

Please note that when purging the gas supply it is usual to have to keep the control knob depressed in the spark position for longer periods of time.

Step 2. To ignite the main burner, rotate the control knob anti-clockwise to the HIGH position (fig 5c)

Fig 5c

For maximum heat output leave the control knob at the high position

For minimum heat output, rotate the control knob clockwise to the LOW position. (Fig 5d)

Becton Bunny & Becton 7 mk3 Gas stoves

9

Image 9
Contents Becton MK Flaming Good Fires Installation ContentsSafety Notices IntroductionGeneral Information Introduction Important Notices Statutory RequirementsCertification Fire Dimensions Operating Instructions Technical DataMax. Heat Setting Min. Heat SettingPositioning the rear lining Operating Instructions Fitting the Lining PanelsOperating Instructions Arranging the Coals Safety Notice Please see Safety Notices ref. Coal setOperating Instructions Lighting & Controlling the Fire Operating Instructions Fitting the Feet Installation Installing the FireFlue System Nacs National Association of Chimney Sweeps telephone 01785See d See cFire Location Graph 1.Combustible Shelf Clearances Installation Hearth Requirements Connecting the GAS SupplyTest Sequence Flame failure device testing Installation Fire TestingInstallation Check List ChecklistServicing Detail of Pilot Assembly Servicing Door Trim Fire Door Glass & Seal Replacement of the Door TrimEnsure the appliance is cold Lifting the door off its hingesRegular Service Servicing Burner AssemblyCleaning Outer Surfaces Servicing Annual ServiceCleaning the Glass See Safety Notices ref coal setServicing Fault DiagnosisAccessories and Options Spare Parts General ComponentsAdd on Canopies Becton Bunny & Becton 7 mk3 Gas stoves Becton Bunny & Becton 7 mk3 Gas stoves Visual Aid Bunny Becton Part Description Spare PartsAFGS080 AFGS080 Control Door Handle Assembly AFGS1085AFGS025 Becton 7 mk3 Lining Kit AFGS1072Customer Registration GuaranteeDate of Visit Company Work Carried Out Signature Service RecordBecton Final Factory Check List ’ve checked it and it’s O.K