Regency FG39-NG installation manual Manual, Please Keep These Instructions For Future Reference

Page 1

Owners & Installation

Manual

Freestanding Gas Stove

Models: FG39-NG

FG39-LPG

PLEASE KEEP THESE INSTRUCTIONS

FOR FUTURE REFERENCE

LISTINGS AND CODE APPROVALS

These gas appliances have been tested in accordance with AS4553-2000, NZS 5262 and have been certified by the Australian Gas Association for installation and operation as described in these Installation and Operating Instructions.

Your unit should be serviced annually by an authorised service person.

WARNING:

Improper installation, adjustment, altera- tion, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional infor- mation consult an authorized installer, serv- ice agency or the gas supplier.

FOR YOUR SAFETY

Do not store or use gasoline or other flamma- ble vapours and liquids in the vicinity of this or any other appliance.

Installation and service must be performed by an authorized installer, service agency or the gas supplier.

FOR YOUR SAFETY

What to do if you smell gas:

Do not try to light any appli- ance

Do not touch any electrical switch: do not use any phone in your building.

Immediately call your gas supplier from a neighbour's phone. Follow the gas sup- plier's instructions.

If you cannot reach your gas supplier, call the fire department.

918-278a

05/26/06

Image 1
Contents Please Keep These Instructions For Future Reference ManualUnit Specifications Table of Contents Safety Label Specifications InstallationGeneral Safety Information Save These InstructionsClearances to Combustibles Installation ChecklistLocating Your Regency GAS Stove Combustion and Ventilation AIRInstallation Precautions Louver InstallationSafety Precautions for Installer Flueing IntroductionClearance k in mm Exterior Flue Termination LocationsFlueing Arrangements Flue Restrictor setting at 40 Mj/h 31 Mj/hHorizontal Terminations for All Fluing Systems Flue Restrictor PositionDV Stove Horizontal Flue KIT DV Stove Horizontal Flue KIT #946-112 InstallationQty. Description OptionalInstallation DURA-FLUE Termination KIT Planning Your Dura-Flue InstallationDURA-FLUE Fluing Components Diagram DURA-FLUE Horizontal InstallationsHint Apply silicone to female end Hole previously drilled DURA-FLUE Vertical TerminationCathedral Ceilings Offset ChartSupport Extensions Round Rdse or Square Sqse MasticAeration Adjustment GAS Pipe Pressure TestingGAS Connection Burner Orifice Pilot Orifice Extrusion Assembly TubeAntenna Control Box Cover Jumper LocationCable Electric Modulator Adjusting the Outlet PressureConversion to Lower BTU Rating LOG SET InstallationLPG Conversion Kit Contains Additional Piece pkg. with unitLava rock Pins on Rear Log SupportPinCutout NotchOptional Remote Control Final Check Front Door InstallationPackaged separately Away from sharp edges WiringOperating Instructions Summary Controls Pilot AdjustmentNormal Operating Sounds GAS Appliances 918-332a Copy of the Lighting Plate InstructionsMaintenance Instructions MaintenanceGOLD-PLATED Doors Latch Adjustment LOG ReplacementGlass Replacement Door GasketFan Replacement FAN MaintenanceAlternate Fan Access Manual Switch Reset Cables Pin Ground Molex Connector WireRemoving Valve Tray Electronic Components Parts List Parts ListRegency FG39 FireGenie Freestanding Gas Stove Description Part# FG39 Main AssemblyFG39 Burner & LOG Assembly FG39 Door Assemblies Regency FG39 FireGenie Freestanding Gas Stove Warranty Lifetime WarrantyConditions Exclusions

FG39-NG, FG39-LPG specifications

The Regency FG39 series comprises two distinct gas fireplaces, the FG39-NG (natural gas) and the FG39-LPG (propane), embodying a perfect blend of functionality, design, and efficiency. These models cater to homeowners seeking an elegant heating solution that combines aesthetic appeal with modern technology.

One of the standout features of the Regency FG39 series is its advanced burner system. Designed for maximum heat output and efficiency, the interlocking burner design produces realistic flames that enhance the ambiance of any room. The flames are adjustable, allowing users to customize their heating experience to suit their preferences and home environment. With an impressive thermal efficiency rating, these fireplaces not only provide warmth but also do so while conserving energy.

An important characteristic of the Regency FG39 series is the extensive range of customizable options available. Homeowners can choose from various decorative fronts, media options like rocks and logs, and colors that complement their interior design themes. This modular approach allows the fireplace to blend seamlessly with any decor, while still standing as a stunning focal point.

Additionally, both models feature a sleek, contemporary design with a large viewing area that maximizes the fire's visual impact. The tempered glass doors not only enhance safety but also add a touch of sophistication. The clean lines and minimalist aesthetic make these fireplaces ideal for both modern and traditional homes.

Technologically, the Regency FG39 series is equipped with high-performance ventilation systems that ensure optimal airflow and heat distribution. This allows for versatile installation options, granting homeowners the flexibility to position the unit in various spaces without compromising on performance.

Furthermore, the unit's easy-to-use digital remote control elevates the user experience. With the ability to adjust temperature settings and flame levels from anywhere in the room, comfort is easily attainable at the touch of a button.

In conclusion, the Regency FG39-NG and FG39-LPG fireplaces offer a compelling solution for homeowners looking for a combination of style, efficiency, and advanced technology. With customizable options, impressive heating systems, and sleek designs, these fireplaces represent the epitome of modern heating solutions, enhancing any living space while ensuring comfort and luxury.