Regency FG39-NG Conversion to Lower BTU Rating, LOG SET Installation, LPG Conversion Kit Contains

Page 19

INSTALLATION

CONVERSION TO LOWER BTU RATING

THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION

LOG SET

INSTALLATION

Read the instructions below carefully

NG Conversion Kit 730-920

Contains:

Qty. Part # Description

1904-240 Burner Orifice #37 (NG)

1918-034 Decal "Converted to 30,000 Btu"

1918-033 Instruction Sheet

LPG Conversion Kit 730-922

Contains:

Qty. Part # Description

1904-390 Burner Orifice #52 (LPG)

1918-034 Decal "Converted to 30,000 Btu"

1918-033 Instruction Sheet

Additional Piece (pkg. with unit:

1Log Bracket Restrictor

1)Shut off the gas supply.

2)Open the front door. Carefully remove the logs and lava rock.

3)Remove burner. See diagram below.

!!

6)Remove burner orifice with a 1/2" spanner and discard.

Burner Orifice

7)Reinstall new burner orifice (NG stamped #37 or LPG stamped #52) and tighten.

8)Reverse steps 3) and 2).

9)Adjust Flue restrictor setting: To set the Flue restriction as indicated in the diagram, sim- ply loosen the screws and push the flue restrictor plate to the correct position. Tight- en the screws.

Unit Btu/h

Restrictor Opening

FG3940 Mj/h

A 45mm

31 Mj/h

B 35mm

and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

The gas log kit contains the following:

a)02-65 Rear Log

b)02-56 Middle Left Log

c)02-44 Front Left Log

d)02-46 Left Top Log

e ) 02-45 Front Right Log

f)02-47 Center Log

g)02-48 Middle Right Log

h)Embers

i)Lava

Note: Install Optional Brick Panels prior to installing logs.

Note: Use a

magnetic type screwdriver if possible.

4) Unscrew the 2 Rear Log Pins and move

to the front hole po- sition.

5)Remove Rear Log Bracket and slide the

Log Bracket Re- strictor between the Rear Log Bracket and the burner, secure with the 2 screws.

Position the Log Bracket Restrictor between

the Rear Log Bracket and the burner.

Flue Restrictor

Flue Restrictor

setting at High Btu/h

setting at Low Btu/h

10)Attach the label "This unit has been con- verted to..." on top of the data badge over the higher Btu information.

11)Check for gas leaks.

12)Check inlet and outlet pressures.

13)Check operation of flame control. Check for proper flame appearance and glow on logs.

The "02" refer numbers (i.e. 02-65) are

molded into the rear of each log.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

2)Sprinkle the embers on the left and right sides of the firebox base.

Embers.Embers

Regency FG39 FireGenie Freestanding Gas Stove

19

Image 19
Contents Please Keep These Instructions For Future Reference ManualUnit Specifications Table of Contents Safety Label Save These Instructions InstallationSpecifications General Safety InformationCombustion and Ventilation AIR Installation ChecklistClearances to Combustibles Locating Your Regency GAS StoveFlueing Introduction Louver InstallationInstallation Precautions Safety Precautions for InstallerClearance k in mm Exterior Flue Termination LocationsFlue Restrictor Position Flue Restrictor setting at 40 Mj/h 31 Mj/hFlueing Arrangements Horizontal Terminations for All Fluing SystemsOptional DV Stove Horizontal Flue KIT #946-112 InstallationDV Stove Horizontal Flue KIT Qty. DescriptionInstallation DURA-FLUE Termination KIT Planning Your Dura-Flue InstallationDURA-FLUE Fluing Components Diagram DURA-FLUE Horizontal InstallationsHint Apply silicone to female end Hole previously drilled DURA-FLUE Vertical TerminationMastic Offset ChartCathedral Ceilings Support Extensions Round Rdse or Square SqseAeration Adjustment GAS Pipe Pressure TestingGAS Connection Jumper Location Pilot Orifice Extrusion Assembly TubeBurner Orifice Antenna Control Box CoverCable Electric Modulator Adjusting the Outlet PressureAdditional Piece pkg. with unit LOG SET InstallationConversion to Lower BTU Rating LPG Conversion Kit ContainsNotch Pins on Rear Log SupportLava rock PinCutoutOptional Remote Control Final Check Front Door InstallationPackaged separately Away from sharp edges WiringOperating Instructions Summary Controls Pilot AdjustmentNormal Operating Sounds GAS Appliances 918-332a Copy of the Lighting Plate InstructionsMaintenance Instructions MaintenanceGOLD-PLATED Doors Door Gasket LOG ReplacementLatch Adjustment Glass ReplacementFan Replacement FAN MaintenanceAlternate Fan Access Manual Switch Reset Cables Pin Ground Molex Connector WireRemoving Valve Tray Electronic Components Parts List Parts ListRegency FG39 FireGenie Freestanding Gas Stove Description Part# FG39 Main AssemblyFG39 Burner & LOG Assembly FG39 Door Assemblies Regency FG39 FireGenie Freestanding Gas Stove Exclusions WarrantyWarranty Lifetime Conditions

FG39-NG, FG39-LPG specifications

The Regency FG39 series comprises two distinct gas fireplaces, the FG39-NG (natural gas) and the FG39-LPG (propane), embodying a perfect blend of functionality, design, and efficiency. These models cater to homeowners seeking an elegant heating solution that combines aesthetic appeal with modern technology.

One of the standout features of the Regency FG39 series is its advanced burner system. Designed for maximum heat output and efficiency, the interlocking burner design produces realistic flames that enhance the ambiance of any room. The flames are adjustable, allowing users to customize their heating experience to suit their preferences and home environment. With an impressive thermal efficiency rating, these fireplaces not only provide warmth but also do so while conserving energy.

An important characteristic of the Regency FG39 series is the extensive range of customizable options available. Homeowners can choose from various decorative fronts, media options like rocks and logs, and colors that complement their interior design themes. This modular approach allows the fireplace to blend seamlessly with any decor, while still standing as a stunning focal point.

Additionally, both models feature a sleek, contemporary design with a large viewing area that maximizes the fire's visual impact. The tempered glass doors not only enhance safety but also add a touch of sophistication. The clean lines and minimalist aesthetic make these fireplaces ideal for both modern and traditional homes.

Technologically, the Regency FG39 series is equipped with high-performance ventilation systems that ensure optimal airflow and heat distribution. This allows for versatile installation options, granting homeowners the flexibility to position the unit in various spaces without compromising on performance.

Furthermore, the unit's easy-to-use digital remote control elevates the user experience. With the ability to adjust temperature settings and flame levels from anywhere in the room, comfort is easily attainable at the touch of a button.

In conclusion, the Regency FG39-NG and FG39-LPG fireplaces offer a compelling solution for homeowners looking for a combination of style, efficiency, and advanced technology. With customizable options, impressive heating systems, and sleek designs, these fireplaces represent the epitome of modern heating solutions, enhancing any living space while ensuring comfort and luxury.