MAINTENANCE

MAINTENANCE

INSTRUCTIONS

Any maintenance required accessing the glass door of the unit must be performed by an authorized service person.

1)Always unplug the power cord before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vac- uuming at least once a year. When cleaning the logs, use a soft clean brush as the logs are fragile and easily damaged.

2)Clean glass (never when unit is hot), ap- pliance, louvres, and door with a damp cloth. Never use an abrasive cleaner. The gold louvres (and optional gold door) may be scratched if abrasives are used to clean them.

The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint (not with wall paint). Regency uses StoveBright Paint - Metallic Black #6309.

3)Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. If there is a problem, call an author- ized service person.

4)The appliance and flueing system must be inspected before use, and at least annual- ly, by an authorized field service person, to ensure that the flow of combustion and ventilation air is not obstructed.

During the annual service call, the burners should be removed from the burner tray and cleaned. Replace the embers - do not block the pilot or burner ports.

5)Keep the area near the appliance clear and free from combustible materials, gasoline and other flammable vapours and liquids.

WARNING: CHILDREN AND ADULTSSHOULDBEALERTEDTO THEHAZARDSOFHIGHSURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDRENSHOULDBECAREFUL- LYSUPERVISEDWHENTHEYARE IN THE SAME ROOM AS THE AP- PLIANCE.

CAUTION: ANY SAFETY SCREEN ORGUARDREMOVEDFORSERV- ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT- ING THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE.

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL AN AUTHORIZEDSERVICETECHNI CIAN TO INSPECT THE APPLI- ANCEANDTOREPLACEANYPART OF CONTROL SYSTEM AND ANY GASCONTROLWHICHHASBEEN UNDERWATER.

6) Verify proper operation after servicing.

GOLD-PLATED DOORS

The 24 carat gold plated finish on the door requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and will void the warranty. Clean any fingerprints off before turning the unit on.

26

Regency FG39 FireGenie Freestanding Gas Stove

Image 26
Contents Manual Please Keep These Instructions For Future ReferenceUnit Specifications Table of Contents Safety Label General Safety Information InstallationSpecifications Save These InstructionsLocating Your Regency GAS Stove Installation ChecklistClearances to Combustibles Combustion and Ventilation AIRSafety Precautions for Installer Louver InstallationInstallation Precautions Flueing IntroductionExterior Flue Termination Locations Clearance k in mmHorizontal Terminations for All Fluing Systems Flue Restrictor setting at 40 Mj/h 31 Mj/hFlueing Arrangements Flue Restrictor PositionQty. Description DV Stove Horizontal Flue KIT #946-112 InstallationDV Stove Horizontal Flue KIT OptionalInstallation DURA-FLUE Fluing Components Planning Your Dura-Flue InstallationDURA-FLUE Termination KIT Hint Apply silicone to female end DURA-FLUE Horizontal InstallationsDiagram DURA-FLUE Vertical Termination Hole previously drilledSupport Extensions Round Rdse or Square Sqse Offset ChartCathedral Ceilings MasticGAS Connection GAS Pipe Pressure TestingAeration Adjustment Antenna Control Box Cover Pilot Orifice Extrusion Assembly TubeBurner Orifice Jumper LocationAdjusting the Outlet Pressure Cable Electric ModulatorLPG Conversion Kit Contains LOG SET InstallationConversion to Lower BTU Rating Additional Piece pkg. with unitPinCutout Pins on Rear Log SupportLava rock NotchPackaged separately Front Door InstallationOptional Remote Control Final Check Wiring Away from sharp edgesOperating Instructions Normal Operating Sounds GAS Appliances Pilot AdjustmentSummary Controls Copy of the Lighting Plate Instructions 918-332aGOLD-PLATED Doors MaintenanceMaintenance Instructions Glass Replacement LOG ReplacementLatch Adjustment Door GasketAlternate Fan Access FAN MaintenanceFan Replacement Removing Valve Tray Pin Ground Molex Connector WireManual Switch Reset Cables Regency FG39 FireGenie Freestanding Gas Stove Parts ListElectronic Components Parts List FG39 Main Assembly Description Part#FG39 Burner & LOG Assembly FG39 Door Assemblies Regency FG39 FireGenie Freestanding Gas Stove Conditions WarrantyWarranty Lifetime Exclusions

FG39-NG, FG39-LPG specifications

The Regency FG39 series comprises two distinct gas fireplaces, the FG39-NG (natural gas) and the FG39-LPG (propane), embodying a perfect blend of functionality, design, and efficiency. These models cater to homeowners seeking an elegant heating solution that combines aesthetic appeal with modern technology.

One of the standout features of the Regency FG39 series is its advanced burner system. Designed for maximum heat output and efficiency, the interlocking burner design produces realistic flames that enhance the ambiance of any room. The flames are adjustable, allowing users to customize their heating experience to suit their preferences and home environment. With an impressive thermal efficiency rating, these fireplaces not only provide warmth but also do so while conserving energy.

An important characteristic of the Regency FG39 series is the extensive range of customizable options available. Homeowners can choose from various decorative fronts, media options like rocks and logs, and colors that complement their interior design themes. This modular approach allows the fireplace to blend seamlessly with any decor, while still standing as a stunning focal point.

Additionally, both models feature a sleek, contemporary design with a large viewing area that maximizes the fire's visual impact. The tempered glass doors not only enhance safety but also add a touch of sophistication. The clean lines and minimalist aesthetic make these fireplaces ideal for both modern and traditional homes.

Technologically, the Regency FG39 series is equipped with high-performance ventilation systems that ensure optimal airflow and heat distribution. This allows for versatile installation options, granting homeowners the flexibility to position the unit in various spaces without compromising on performance.

Furthermore, the unit's easy-to-use digital remote control elevates the user experience. With the ability to adjust temperature settings and flame levels from anywhere in the room, comfort is easily attainable at the touch of a button.

In conclusion, the Regency FG39-NG and FG39-LPG fireplaces offer a compelling solution for homeowners looking for a combination of style, efficiency, and advanced technology. With customizable options, impressive heating systems, and sleek designs, these fireplaces represent the epitome of modern heating solutions, enhancing any living space while ensuring comfort and luxury.