INSTALLATION

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The REGENCY Room Sealed Freestanding Gas Stove must be installed in accordance AG601 and NZS 5261 and with these instructions. Carefully read all the instructions in this manual first. Consult the building authority having juris- diction to determine the need for a permit prior to starting the installation.

Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or war- ranty.

Note: These instructions take prece- dence over Simpson Dura-Flue in- structions.

SPECIFICATIONS

Fuels: FG39-NG is approved for use with NG.

FG39-LPG is approved for use with liquefied petroleum gases (LPG).

Electrical: 240V A.C. system.

Circulation Fan: Variable speed, 125/75.

Log Sets: Ceramic fibre, 7 per set.

Flue System: Coaxial (6-5/8" outer / 4" inner liner) rigid flue and termination cap.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIRS SHOULDBEDONEBYANAUTHOR- IZED SERVICE PERSON. THIS AP- PLIANCESHOULDBEINSTALLED, REPAIRED, INSPECTED BEFORE USE AND AT LEAST ANNUALLY BYANAUTHORIZEDSERVICEPER- SON. MORE FREQUENT CLEAN- ING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPET-

ING,ETC. ITISIMPERATIVETHAT THE CONTROL COMPARTMENT, BURNERSANDCIRCULATINGAIR PASSAGEWAYS OF THE APPLI- ANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LO- CATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILLVOIDYOURWARRANTYAND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDRENANDADULTSSHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISEDWHEN THEYAREINTHESAMEROOMAS THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACEDONORNEARTHEAPPLI- ANCE.

1)Provide adequate clearances for servicing, proper operation and around the air open- ings into the combustion chamber.

2)The appliance may be installed on a flat, solid, continuous surface (e.g. wood, met- al, concrete). This may be the floor, or it can be raised up on a platform to enhance its visual impact. The appliance may be in- stalled on carpeting, tile, wood flooring or other combustible material, because the appliance's metal pedestal base extends the full width and depth of the appliance. The Regency Room Sealed Freestanding Gas Stove can be installed in a wide variety of ways and will fit nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a cor- ner.

3)The Regency Room Sealed Freestanding Gas Stove is approved for alcove installa- tions, which meet the clearances listed on

page 6. This unit is approved for manufac- tured home installations, see page 9 for the required flue arrangements. If installed into a manufactured home the unit must be bolted down to the floor.

4)This appliance is Listed for bedroom instal- lations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

5)This appliance is Listed for Alcove installa- tions, maintain minimum Alcove clearances as follows, minimum width of 48" (1219mm), a maximum depth of 36" (914mm), and minimum ceiling height of 64"(1626mm).

6)We recommend that you plan your installa- tion on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized building inspector review your plans before installation.

GENERAL SAFETY

INFORMATION

1)The appliance shall be installed in accord- ance with the manufacturer's installation instructions,local gas fitting regulations, mu- nicipal building codes, water supply regu- lations, electrical wiring regulations, with AS5601-2004 (AGA gas installation code) NZS 5261 (New Zealand)

2)Installation and repair should be done ONLY by an authorised person.

3)DO NOT CONNECT TO MASONARY FLUE.

4)This appliance must be connected to the specified flue and termination cap to the outside of the building enve- lope. Never flue to another room or inside a building. Make sure that the flue is fitted as per Flueing instruc- tions.

5)Inspect the flueing system annually for blockage and any signs of deterioration.

6)Flueing terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the appliance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

9)Wear gloves and safety glasses for protec- tion while doing required maintenance.

Regency FG39 FireGenie Freestanding Gas Stove

5

Image 5
Contents Please Keep These Instructions For Future Reference ManualUnit Specifications Table of Contents Safety Label Specifications InstallationGeneral Safety Information Save These InstructionsClearances to Combustibles Installation ChecklistLocating Your Regency GAS Stove Combustion and Ventilation AIRInstallation Precautions Louver InstallationSafety Precautions for Installer Flueing IntroductionClearance k in mm Exterior Flue Termination LocationsFlueing Arrangements Flue Restrictor setting at 40 Mj/h 31 Mj/hHorizontal Terminations for All Fluing Systems Flue Restrictor PositionDV Stove Horizontal Flue KIT DV Stove Horizontal Flue KIT #946-112 InstallationQty. Description OptionalInstallation DURA-FLUE Fluing Components Planning Your Dura-Flue InstallationDURA-FLUE Termination KIT Hint Apply silicone to female end DURA-FLUE Horizontal InstallationsDiagram Hole previously drilled DURA-FLUE Vertical TerminationCathedral Ceilings Offset ChartSupport Extensions Round Rdse or Square Sqse MasticGAS Connection GAS Pipe Pressure TestingAeration Adjustment Burner Orifice Pilot Orifice Extrusion Assembly TubeAntenna Control Box Cover Jumper LocationCable Electric Modulator Adjusting the Outlet PressureConversion to Lower BTU Rating LOG SET InstallationLPG Conversion Kit Contains Additional Piece pkg. with unitLava rock Pins on Rear Log SupportPinCutout NotchPackaged separately Front Door InstallationOptional Remote Control Final Check Away from sharp edges WiringOperating Instructions Normal Operating Sounds GAS Appliances Pilot AdjustmentSummary Controls 918-332a Copy of the Lighting Plate InstructionsGOLD-PLATED Doors MaintenanceMaintenance Instructions Latch Adjustment LOG ReplacementGlass Replacement Door GasketAlternate Fan Access FAN MaintenanceFan Replacement Removing Valve Tray Pin Ground Molex Connector WireManual Switch Reset Cables Regency FG39 FireGenie Freestanding Gas Stove Parts ListElectronic Components Parts List Description Part# FG39 Main AssemblyFG39 Burner & LOG Assembly FG39 Door Assemblies Regency FG39 FireGenie Freestanding Gas Stove Warranty Lifetime WarrantyConditions Exclusions

FG39-NG, FG39-LPG specifications

The Regency FG39 series comprises two distinct gas fireplaces, the FG39-NG (natural gas) and the FG39-LPG (propane), embodying a perfect blend of functionality, design, and efficiency. These models cater to homeowners seeking an elegant heating solution that combines aesthetic appeal with modern technology.

One of the standout features of the Regency FG39 series is its advanced burner system. Designed for maximum heat output and efficiency, the interlocking burner design produces realistic flames that enhance the ambiance of any room. The flames are adjustable, allowing users to customize their heating experience to suit their preferences and home environment. With an impressive thermal efficiency rating, these fireplaces not only provide warmth but also do so while conserving energy.

An important characteristic of the Regency FG39 series is the extensive range of customizable options available. Homeowners can choose from various decorative fronts, media options like rocks and logs, and colors that complement their interior design themes. This modular approach allows the fireplace to blend seamlessly with any decor, while still standing as a stunning focal point.

Additionally, both models feature a sleek, contemporary design with a large viewing area that maximizes the fire's visual impact. The tempered glass doors not only enhance safety but also add a touch of sophistication. The clean lines and minimalist aesthetic make these fireplaces ideal for both modern and traditional homes.

Technologically, the Regency FG39 series is equipped with high-performance ventilation systems that ensure optimal airflow and heat distribution. This allows for versatile installation options, granting homeowners the flexibility to position the unit in various spaces without compromising on performance.

Furthermore, the unit's easy-to-use digital remote control elevates the user experience. With the ability to adjust temperature settings and flame levels from anywhere in the room, comfort is easily attainable at the touch of a button.

In conclusion, the Regency FG39-NG and FG39-LPG fireplaces offer a compelling solution for homeowners looking for a combination of style, efficiency, and advanced technology. With customizable options, impressive heating systems, and sleek designs, these fireplaces represent the epitome of modern heating solutions, enhancing any living space while ensuring comfort and luxury.