INSTALLATION

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this appli- ance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by an authorised service person. An authorised service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids).

INSTALLATION

CHECKLIST

1)Check Clearances to Combustibles (page 6), location of unit (page 6) and fluing requirements (pages 8 to 10).

2)Install Louvers, page 7.

3)Install fluing, either with the DV Stove Hor- izontal Flue Kit (page 10) or the Dura-Flue Termination kits (page 12). Set Flue Restric- tors, page 9.

4)Make gas connections, page 16. Test the pilot. Must be as per diagram.

5)If necessary, convert to LPG (page 17) or convert to lower Btu rating (page 19).

6)Test Gas Pressure, page 16.

7)Install log set, see page 19.

8)Install Front Door Front, page 21.

9)Install optional Remote Control, page 21.

10)Final check, page 21.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibil- ity of the manufacturer.

CLEARANCES TO COMBUSTIBLES

The clearances listed are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearances do not coincide.

For example, if the appliance is set as indicated in one of the figures but the connector is too close, move the stove until the correct clear- ance to the connector is obtained.

This appliance may be installed only with the clearances as shown in the situations pic- tured. Do not combine clearances from one type of installation with another in order to achieve closer clearances.

This unit can be installed on a solid combustible surface like a wood floor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with unit) is installed.

Use the minimum clearances shown in the diagrams below:

FG39-NG & FG39-LPG Clearances

A Side Wall to Unit

 

 

190 mm

B Back Wall to Unit

 

 

150 mm

E Side Wall to Unit

 

 

50 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FG39-NG & FG39-LPG

Reference Dimensions

C Back Wall to Flue Centerline

11" / 280 mm

 

D Side Wall to Flue Centerline

521 mm

 

F Side Wall to Flue Centerline

280 mm

 

 

 

 

 

 

 

 

 

Minimum ceiling height is 914 mm from top of unit.

LOCATING YOUR

REGENCY GAS STOVE

When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper opera- tion.

A)Cross Corner

B)Room Divider

C)Island

D)Flat on Wall

E)Flat on Wall Corner

F)Flush with Wall/ Alcove

 

12’ (4m)

 

Max.

 

B

A

12’ (4m)

 

Max.

F

 

 

C

E

D

For Flue Termination requirements, see page 8.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer.

This includes:

1)Clocking the appliance to ensure the correct firing rate (rate noted on label) after burning appliance for 15 minutes.

COMBUSTION AND VENTILATION AIR

The combustion air from this appliance is drawn from outside the building through the outer flue.

Extra provision for combustion air inside the room is not required.

6

Regency FG39 FireGenie Freestanding Gas Stove

Image 6
Contents Manual Please Keep These Instructions For Future ReferenceUnit Specifications Table of Contents Safety Label General Safety Information InstallationSpecifications Save These InstructionsLocating Your Regency GAS Stove Installation ChecklistClearances to Combustibles Combustion and Ventilation AIRSafety Precautions for Installer Louver InstallationInstallation Precautions Flueing IntroductionExterior Flue Termination Locations Clearance k in mmHorizontal Terminations for All Fluing Systems Flue Restrictor setting at 40 Mj/h 31 Mj/hFlueing Arrangements Flue Restrictor PositionQty. Description DV Stove Horizontal Flue KIT #946-112 InstallationDV Stove Horizontal Flue KIT OptionalInstallation Planning Your Dura-Flue Installation DURA-FLUE Termination KITDURA-FLUE Fluing Components DURA-FLUE Horizontal Installations DiagramHint Apply silicone to female end DURA-FLUE Vertical Termination Hole previously drilledSupport Extensions Round Rdse or Square Sqse Offset ChartCathedral Ceilings MasticGAS Pipe Pressure Testing Aeration AdjustmentGAS Connection Antenna Control Box Cover Pilot Orifice Extrusion Assembly TubeBurner Orifice Jumper LocationAdjusting the Outlet Pressure Cable Electric ModulatorLPG Conversion Kit Contains LOG SET InstallationConversion to Lower BTU Rating Additional Piece pkg. with unitPinCutout Pins on Rear Log SupportLava rock NotchFront Door Installation Optional Remote Control Final CheckPackaged separately Wiring Away from sharp edgesOperating Instructions Pilot Adjustment Summary ControlsNormal Operating Sounds GAS Appliances Copy of the Lighting Plate Instructions 918-332aMaintenance Maintenance InstructionsGOLD-PLATED Doors Glass Replacement LOG ReplacementLatch Adjustment Door GasketFAN Maintenance Fan ReplacementAlternate Fan Access Pin Ground Molex Connector Wire Manual Switch Reset CablesRemoving Valve Tray Parts List Electronic Components Parts ListRegency FG39 FireGenie Freestanding Gas Stove FG39 Main Assembly Description Part#FG39 Burner & LOG Assembly FG39 Door Assemblies Regency FG39 FireGenie Freestanding Gas Stove Conditions WarrantyWarranty Lifetime Exclusions

FG39-NG, FG39-LPG specifications

The Regency FG39 series comprises two distinct gas fireplaces, the FG39-NG (natural gas) and the FG39-LPG (propane), embodying a perfect blend of functionality, design, and efficiency. These models cater to homeowners seeking an elegant heating solution that combines aesthetic appeal with modern technology.

One of the standout features of the Regency FG39 series is its advanced burner system. Designed for maximum heat output and efficiency, the interlocking burner design produces realistic flames that enhance the ambiance of any room. The flames are adjustable, allowing users to customize their heating experience to suit their preferences and home environment. With an impressive thermal efficiency rating, these fireplaces not only provide warmth but also do so while conserving energy.

An important characteristic of the Regency FG39 series is the extensive range of customizable options available. Homeowners can choose from various decorative fronts, media options like rocks and logs, and colors that complement their interior design themes. This modular approach allows the fireplace to blend seamlessly with any decor, while still standing as a stunning focal point.

Additionally, both models feature a sleek, contemporary design with a large viewing area that maximizes the fire's visual impact. The tempered glass doors not only enhance safety but also add a touch of sophistication. The clean lines and minimalist aesthetic make these fireplaces ideal for both modern and traditional homes.

Technologically, the Regency FG39 series is equipped with high-performance ventilation systems that ensure optimal airflow and heat distribution. This allows for versatile installation options, granting homeowners the flexibility to position the unit in various spaces without compromising on performance.

Furthermore, the unit's easy-to-use digital remote control elevates the user experience. With the ability to adjust temperature settings and flame levels from anywhere in the room, comfort is easily attainable at the touch of a button.

In conclusion, the Regency FG39-NG and FG39-LPG fireplaces offer a compelling solution for homeowners looking for a combination of style, efficiency, and advanced technology. With customizable options, impressive heating systems, and sleek designs, these fireplaces represent the epitome of modern heating solutions, enhancing any living space while ensuring comfort and luxury.