Regency FG39-LPG DV Stove Horizontal Flue KIT #946-112 Installation, Qty. Description

Page 10

INSTALLATION

DV STOVE HORIZONTAL FLUE KIT

Horizontal Stove Flue Kit (Part # 946-112) includes all the parts needed to install the FG39 Freestanding Gas unit with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown in your manual.

Qty. Description

1) 2 Rigid Pipe Section 1.2m length, 165mm inside diameter

2) 1 Flex Liner, compressed aluminium 2 ply liner, 102mm inside diameter

3) 4 spring spacers

4) 1 90 deg. Elbow

5) 1 Decorative Wall Trim

6) 1 Adapter

7) 1 AstroCap Termination Cap

8) 2 Trim Collar

9) 1 tube of Mill-Pac, high temperature sealant

10)12 Screws, #8 x 1/2" (13mm) Self tapping, Stainless Steel

11) 14 Screws, #8 x 1/2" (13mm) Self tapping, Black

12) 4 Screws #8 x 1-1/2" (38mm) Drill Point, Stainless Steel

Optional:

946-206 Vinyl Siding Standoff for AstroCap

Note:

a ) Liner sections should be continuous without any joints or seams.

b) This is an approved system, therefore components in this system must not be substituted for any other manufactur- er's products.

c) Wall Thimble is required when install- ing through a combustible wall.

DV STOVE HORIZONTAL FLUE KIT (#946-112) INSTALLATION

Review the following sequence of instruc- tions which are typical of most installations. The sequence may vary depending on wall thickness. Refer to flue location and clear- ance dimensions on pages 8 to 9.

1)Set the unit in its desired location. Check to determine if wall studs will be in the way of the fluing system, adjust location until all clearances are met and there are no obstructions.

Note: A 1-1/2"(38mm) clearance around the outer pipe must be main- tained except that only a 1" (25mm) clearance is needed at the termination end.

IMPORTANT:

Do not locate termination hood where excessive snow or ice buildup may oc- cur. Be sure to check flue termination area after snow falls, and clear to pre- vent accidental blockage of fluing sys- tem. When using snow blowers, make sure snow is not directed towards flue termination area.

Minimum Installation Height:

FG39: 59-3/4" ( 1518mm)

2)Assemble a trial fit to determine the ver- tical center-line for the flue termination.

a)Cut a 241mm round hole on both the interior and exterior wall.

b)Attach the 2 ft. (.6m) pipe section to the flue terminal and slide into posi- tion from the exterior. The larger diameter end of the adjustable pipe goes to the flue terminal.

c)Install the 90o elbow onto the adjust- able pipe to determine the vertical centerline of the starter collar on the unit.

Note: if the centerline cannot be met, the adjustable sections will have to be cut.

10

Regency FG39 FireGenie Freestanding Gas Stove

Image 10
Contents Manual Please Keep These Instructions For Future ReferenceUnit Specifications Table of Contents Safety Label General Safety Information InstallationSpecifications Save These InstructionsLocating Your Regency GAS Stove Installation ChecklistClearances to Combustibles Combustion and Ventilation AIRSafety Precautions for Installer Louver InstallationInstallation Precautions Flueing IntroductionExterior Flue Termination Locations Clearance k in mmHorizontal Terminations for All Fluing Systems Flue Restrictor setting at 40 Mj/h 31 Mj/hFlueing Arrangements Flue Restrictor PositionQty. Description DV Stove Horizontal Flue KIT #946-112 InstallationDV Stove Horizontal Flue KIT OptionalInstallation DURA-FLUE Termination KIT Planning Your Dura-Flue InstallationDURA-FLUE Fluing Components Diagram DURA-FLUE Horizontal InstallationsHint Apply silicone to female end DURA-FLUE Vertical Termination Hole previously drilledSupport Extensions Round Rdse or Square Sqse Offset ChartCathedral Ceilings MasticAeration Adjustment GAS Pipe Pressure TestingGAS Connection Antenna Control Box Cover Pilot Orifice Extrusion Assembly TubeBurner Orifice Jumper LocationAdjusting the Outlet Pressure Cable Electric ModulatorLPG Conversion Kit Contains LOG SET InstallationConversion to Lower BTU Rating Additional Piece pkg. with unitPinCutout Pins on Rear Log SupportLava rock NotchOptional Remote Control Final Check Front Door InstallationPackaged separately Wiring Away from sharp edgesOperating Instructions Summary Controls Pilot AdjustmentNormal Operating Sounds GAS Appliances Copy of the Lighting Plate Instructions 918-332aMaintenance Instructions MaintenanceGOLD-PLATED Doors Glass Replacement LOG ReplacementLatch Adjustment Door GasketFan Replacement FAN MaintenanceAlternate Fan Access Manual Switch Reset Cables Pin Ground Molex Connector WireRemoving Valve Tray Electronic Components Parts List Parts ListRegency FG39 FireGenie Freestanding Gas Stove FG39 Main Assembly Description Part#FG39 Burner & LOG Assembly FG39 Door Assemblies Regency FG39 FireGenie Freestanding Gas Stove Conditions WarrantyWarranty Lifetime Exclusions

FG39-NG, FG39-LPG specifications

The Regency FG39 series comprises two distinct gas fireplaces, the FG39-NG (natural gas) and the FG39-LPG (propane), embodying a perfect blend of functionality, design, and efficiency. These models cater to homeowners seeking an elegant heating solution that combines aesthetic appeal with modern technology.

One of the standout features of the Regency FG39 series is its advanced burner system. Designed for maximum heat output and efficiency, the interlocking burner design produces realistic flames that enhance the ambiance of any room. The flames are adjustable, allowing users to customize their heating experience to suit their preferences and home environment. With an impressive thermal efficiency rating, these fireplaces not only provide warmth but also do so while conserving energy.

An important characteristic of the Regency FG39 series is the extensive range of customizable options available. Homeowners can choose from various decorative fronts, media options like rocks and logs, and colors that complement their interior design themes. This modular approach allows the fireplace to blend seamlessly with any decor, while still standing as a stunning focal point.

Additionally, both models feature a sleek, contemporary design with a large viewing area that maximizes the fire's visual impact. The tempered glass doors not only enhance safety but also add a touch of sophistication. The clean lines and minimalist aesthetic make these fireplaces ideal for both modern and traditional homes.

Technologically, the Regency FG39 series is equipped with high-performance ventilation systems that ensure optimal airflow and heat distribution. This allows for versatile installation options, granting homeowners the flexibility to position the unit in various spaces without compromising on performance.

Furthermore, the unit's easy-to-use digital remote control elevates the user experience. With the ability to adjust temperature settings and flame levels from anywhere in the room, comfort is easily attainable at the touch of a button.

In conclusion, the Regency FG39-NG and FG39-LPG fireplaces offer a compelling solution for homeowners looking for a combination of style, efficiency, and advanced technology. With customizable options, impressive heating systems, and sleek designs, these fireplaces represent the epitome of modern heating solutions, enhancing any living space while ensuring comfort and luxury.