Regency FG39-NG, FG39-LPG LOG Replacement, Door Gasket, Latch Adjustment, Glass Replacement

Page 27

MAINTENANCE

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will al- ter the unit’s performance which is not covered under warranty.

DOOR GASKET

If the door gasket requires replacement use 7/ 8" diameter oval door gasket (Part # 650-920).

LATCH ADJUSTMENT

The door latch may require adjustment as the door gasket material compresses after a few fires and after glass replacement. Turn the adjustable catch to tighten or loosen the latch.

GLASS

REPLACEMENT

Your Regency stove is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the eflue that you break your glass by impact, purchase your replace- ment door from an authorized Regency dealer only, and follow our step-by-step instructions for replacement. The glass is not sold sepa- rately, as it must be properly sealed in the door frame.

Replacement Part #

940-325/P FG39 Wraparound Glass

940-322/P FG39 Panel Center Glass

940-323/P FG39 Panel Side Glass

WARNING:Donotoperateappliancewith glass panels removed, cracked or bro- ken. Replacement of the glass should be done by a licensed or qualified serv- ice person.

Note: Wearing gloves will protect your hands while handling glass.

Panel Glass Replacement

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Pull out the door gasket.

3)Remove the nuts holding the glass retainers in place.

4)Remove the glass retainers (sides, top and bottom) and the door catch plate.

5)Replace the glass. The glass must have gasketing around it.

6)Reverse the previous steps, replace the retainers and fasten with the nuts but do not overtighten, as this can break the glass. Note: the door catch plate fits on top of the left side retainer.

7)Put gasket glue on the retainers, but do not put glue on the screws. Replace the door gasket, the two ends butt tight together on the bottom edge of the door.

8)Replace door on the stove and check the seal.

Panel Glass Door Assembly

Wraparound Assembly Door (same glass retainers as the Panel Assembly)

Mitred Glass Replacement

Removing Glass:

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Pull out the door gasket.

3)Remove the 24 nuts holding the glass retainers in place. Do not remove the nuts underneath the retainers.

4)Remove the door catch plate.

5)Remove glass retainers on sides first (3 each side) then remove two center retain- ers.

Note: Center glass retainers are glued to center glass.

6)Remove glass from extrusions. When re- moving center glass, leave white insula- tion in place.

Installing Glass:

1) Install both center and side glass onto extrusions as per diagram.

2)Place glass assembly into door frame.

3)Install retainers by placing 1 drop of glue where previously glued and put in place.

4)Install side retainers.

5)Install door catch plate.

6)Install the 24 nuts loosely, do not tighten yet.

Regency FG39 FireGenie Freestanding Gas Stove

27

Image 27
Contents Please Keep These Instructions For Future Reference ManualUnit Specifications Table of Contents Safety Label Save These Instructions InstallationSpecifications General Safety InformationCombustion and Ventilation AIR Installation ChecklistClearances to Combustibles Locating Your Regency GAS StoveFlueing Introduction Louver InstallationInstallation Precautions Safety Precautions for InstallerClearance k in mm Exterior Flue Termination LocationsFlue Restrictor Position Flue Restrictor setting at 40 Mj/h 31 Mj/hFlueing Arrangements Horizontal Terminations for All Fluing SystemsOptional DV Stove Horizontal Flue KIT #946-112 InstallationDV Stove Horizontal Flue KIT Qty. DescriptionInstallation Planning Your Dura-Flue Installation DURA-FLUE Termination KITDURA-FLUE Fluing Components DURA-FLUE Horizontal Installations DiagramHint Apply silicone to female end Hole previously drilled DURA-FLUE Vertical TerminationMastic Offset ChartCathedral Ceilings Support Extensions Round Rdse or Square SqseGAS Pipe Pressure Testing Aeration AdjustmentGAS Connection Jumper Location Pilot Orifice Extrusion Assembly TubeBurner Orifice Antenna Control Box CoverCable Electric Modulator Adjusting the Outlet PressureAdditional Piece pkg. with unit LOG SET InstallationConversion to Lower BTU Rating LPG Conversion Kit ContainsNotch Pins on Rear Log SupportLava rock PinCutoutFront Door Installation Optional Remote Control Final CheckPackaged separately Away from sharp edges WiringOperating Instructions Pilot Adjustment Summary ControlsNormal Operating Sounds GAS Appliances 918-332a Copy of the Lighting Plate InstructionsMaintenance Maintenance InstructionsGOLD-PLATED Doors Door Gasket LOG ReplacementLatch Adjustment Glass ReplacementFAN Maintenance Fan ReplacementAlternate Fan Access Pin Ground Molex Connector Wire Manual Switch Reset CablesRemoving Valve Tray Parts List Electronic Components Parts ListRegency FG39 FireGenie Freestanding Gas Stove Description Part# FG39 Main AssemblyFG39 Burner & LOG Assembly FG39 Door Assemblies Regency FG39 FireGenie Freestanding Gas Stove Exclusions WarrantyWarranty Lifetime Conditions

FG39-NG, FG39-LPG specifications

The Regency FG39 series comprises two distinct gas fireplaces, the FG39-NG (natural gas) and the FG39-LPG (propane), embodying a perfect blend of functionality, design, and efficiency. These models cater to homeowners seeking an elegant heating solution that combines aesthetic appeal with modern technology.

One of the standout features of the Regency FG39 series is its advanced burner system. Designed for maximum heat output and efficiency, the interlocking burner design produces realistic flames that enhance the ambiance of any room. The flames are adjustable, allowing users to customize their heating experience to suit their preferences and home environment. With an impressive thermal efficiency rating, these fireplaces not only provide warmth but also do so while conserving energy.

An important characteristic of the Regency FG39 series is the extensive range of customizable options available. Homeowners can choose from various decorative fronts, media options like rocks and logs, and colors that complement their interior design themes. This modular approach allows the fireplace to blend seamlessly with any decor, while still standing as a stunning focal point.

Additionally, both models feature a sleek, contemporary design with a large viewing area that maximizes the fire's visual impact. The tempered glass doors not only enhance safety but also add a touch of sophistication. The clean lines and minimalist aesthetic make these fireplaces ideal for both modern and traditional homes.

Technologically, the Regency FG39 series is equipped with high-performance ventilation systems that ensure optimal airflow and heat distribution. This allows for versatile installation options, granting homeowners the flexibility to position the unit in various spaces without compromising on performance.

Furthermore, the unit's easy-to-use digital remote control elevates the user experience. With the ability to adjust temperature settings and flame levels from anywhere in the room, comfort is easily attainable at the touch of a button.

In conclusion, the Regency FG39-NG and FG39-LPG fireplaces offer a compelling solution for homeowners looking for a combination of style, efficiency, and advanced technology. With customizable options, impressive heating systems, and sleek designs, these fireplaces represent the epitome of modern heating solutions, enhancing any living space while ensuring comfort and luxury.