Regency FG39-NG Cathedral Ceilings, Offset Chart, Support Extensions Round Rdse or Square Sqse

Page 15

INSTALLATION

Notes:

a)For multistorey vertical installations, a Ceiling Fire stop (Part # 963) is required at the second floor, and any subse- quent floor. Diagram 13. The opening should be framed to 10 " x 10" (254mm x 254mm) inside dimensions, in the same manner as shown in diagram 10.

nails

Ceiling Firestop

1-1/4"

 

(32mm)

 

Min.

1-1/4" (32mm) Min.

 

CATHEDRAL CEILINGS

Round Support (RDS) & Square Support (SQS)

If your home has a cathedral ceiling (no attic space between the ceiling and the roof), install the chimney and support as follows.

1)Situate the chimney in a convenient loca- tion as near as possible to the appliance outlet. Cut and frame a hole in the roof for the support. The sides of this hole must be vertical with 1 1/4" (32mm) clearance.

2)Place the support in the opening. Lower it to the correct height as determined by the table and diagram below.

trimmed (e.g.: to fit under a flashing). Place the Finish Collar around the support and fasten it to the ceiling using the screws provided.

3) Use appropriate roof flashing. Place the

flashing under the upper shingles and on

top of the lower shingles approximately half

of the flashing should be under the shin-

gles.

4) Assemble the desired lengths of Black Pipe

and Elbows necessary to reach from the

appliance adaptor up through the support

box and flashing to proper height as per Dia.

12, local codes or page 9. Ensure that all

pipe and elbow connections are in their fully

twist lock position.

5) Ensure flue is vertical and secure flashing

to the roof with roofing nails. Slide the storm

collar over the pipe section and seal with a

1-1/4" (32mm) Min.

1-1/4" (32mm) Min.

Diagram 13

Offset Chart

Slope

 

"X"

 

 

 

 

0/12

- 2/12

 

4" (102mm)

2/12

- 7/12

 

5-1/2" (140mm)

 

 

 

7/12

- 12/12

6-3/4" (172mm)

 

 

12/12 - 24/12

7-1/2" (191mm)

 

 

 

 

 

 

24/12+

 

 

 

 

12-1/2" (378mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mastic.

6) Twist lock the flue cap on to the last section.

Support Extensions - Round (RDSE) or Square (SQSE)

Steep pitched cathedral ceilings may require the use of a support extension. This piece fits down inside the support and can be adjusted to increase the support's length by up to 22" (559mm). The extension is attached to the support using the eight metal screws provided. Be sure there is at least a 2 inch overlap where the extension joins the support.

b)Any occupied areas above the first floor, including closets and storage spaces, through which the vertical flue passes, must be enclosed.

Using a level, make sure the support is vertical. If the support extends above the roof, cut it flush with the top of the roof. Nail the support to the frame opening using (8) 3" (76mm) spiral nails or #8 x 1-1/2" (38mm) screws.

Note: If you are using a 6" square sup- port you may find it difficult to screw it in place because it is fairly small inside.

Simpson Dura-Flue has provided angle brackets with this support which can be screwed to the outside of the support box and nailed to surrounding framing as re- quired. Use a minimum of four #8 x 1/2" (13mm) screws per bracket. In some cases these brackets may need to be

Regency FG39 FireGenie Freestanding Gas Stove

15

Image 15
Contents Please Keep These Instructions For Future Reference ManualUnit Specifications Table of Contents Safety Label Save These Instructions InstallationSpecifications General Safety InformationCombustion and Ventilation AIR Installation ChecklistClearances to Combustibles Locating Your Regency GAS StoveFlueing Introduction Louver InstallationInstallation Precautions Safety Precautions for InstallerClearance k in mm Exterior Flue Termination LocationsFlue Restrictor Position Flue Restrictor setting at 40 Mj/h 31 Mj/hFlueing Arrangements Horizontal Terminations for All Fluing SystemsOptional DV Stove Horizontal Flue KIT #946-112 InstallationDV Stove Horizontal Flue KIT Qty. DescriptionInstallation Planning Your Dura-Flue Installation DURA-FLUE Termination KITDURA-FLUE Fluing Components DURA-FLUE Horizontal Installations DiagramHint Apply silicone to female end Hole previously drilled DURA-FLUE Vertical TerminationMastic Offset ChartCathedral Ceilings Support Extensions Round Rdse or Square SqseGAS Pipe Pressure Testing Aeration AdjustmentGAS Connection Jumper Location Pilot Orifice Extrusion Assembly TubeBurner Orifice Antenna Control Box CoverCable Electric Modulator Adjusting the Outlet PressureAdditional Piece pkg. with unit LOG SET InstallationConversion to Lower BTU Rating LPG Conversion Kit ContainsNotch Pins on Rear Log SupportLava rock PinCutoutFront Door Installation Optional Remote Control Final CheckPackaged separately Away from sharp edges WiringOperating Instructions Pilot Adjustment Summary ControlsNormal Operating Sounds GAS Appliances 918-332a Copy of the Lighting Plate InstructionsMaintenance Maintenance InstructionsGOLD-PLATED Doors Door Gasket LOG ReplacementLatch Adjustment Glass ReplacementFAN Maintenance Fan ReplacementAlternate Fan Access Pin Ground Molex Connector Wire Manual Switch Reset CablesRemoving Valve Tray Parts List Electronic Components Parts ListRegency FG39 FireGenie Freestanding Gas Stove Description Part# FG39 Main AssemblyFG39 Burner & LOG Assembly FG39 Door Assemblies Regency FG39 FireGenie Freestanding Gas Stove Exclusions WarrantyWarranty Lifetime Conditions

FG39-NG, FG39-LPG specifications

The Regency FG39 series comprises two distinct gas fireplaces, the FG39-NG (natural gas) and the FG39-LPG (propane), embodying a perfect blend of functionality, design, and efficiency. These models cater to homeowners seeking an elegant heating solution that combines aesthetic appeal with modern technology.

One of the standout features of the Regency FG39 series is its advanced burner system. Designed for maximum heat output and efficiency, the interlocking burner design produces realistic flames that enhance the ambiance of any room. The flames are adjustable, allowing users to customize their heating experience to suit their preferences and home environment. With an impressive thermal efficiency rating, these fireplaces not only provide warmth but also do so while conserving energy.

An important characteristic of the Regency FG39 series is the extensive range of customizable options available. Homeowners can choose from various decorative fronts, media options like rocks and logs, and colors that complement their interior design themes. This modular approach allows the fireplace to blend seamlessly with any decor, while still standing as a stunning focal point.

Additionally, both models feature a sleek, contemporary design with a large viewing area that maximizes the fire's visual impact. The tempered glass doors not only enhance safety but also add a touch of sophistication. The clean lines and minimalist aesthetic make these fireplaces ideal for both modern and traditional homes.

Technologically, the Regency FG39 series is equipped with high-performance ventilation systems that ensure optimal airflow and heat distribution. This allows for versatile installation options, granting homeowners the flexibility to position the unit in various spaces without compromising on performance.

Furthermore, the unit's easy-to-use digital remote control elevates the user experience. With the ability to adjust temperature settings and flame levels from anywhere in the room, comfort is easily attainable at the touch of a button.

In conclusion, the Regency FG39-NG and FG39-LPG fireplaces offer a compelling solution for homeowners looking for a combination of style, efficiency, and advanced technology. With customizable options, impressive heating systems, and sleek designs, these fireplaces represent the epitome of modern heating solutions, enhancing any living space while ensuring comfort and luxury.