Regency FG39-NG, FG39-LPG installation manual FG39 Main Assembly, Description Part#

Page 31

PARTS LIST

Part # Description

1)560-920 Louver Assy - Gold (Set)

4)730-038 Door Screen (Austraila only)

8)730-560 Relief Door Assembly

(with gasket)

10)730-034 Mounting Plate Gasket

11)730-519/P Fan Assembly (240 Volt)

910-169/P Fan Motor (240 Volt)

12)910-714 Power Cord (240 Volt)

15)560-525 Pedestal Assembly

16)730-039 Pedestal Door

17)904-257 Pedestal Door Magnet

18)560-025 Pedestal Back

19)730-530 Side Panel Door Assy (Right Side)

20)730-525 Side Panel Door Assy (Left Side)

21)560-031 Side Panel Door Hinge

23)904-258 Side Panel Door Magnet

24) 948-255 Door Latch

FG39 MAIN ASSEMBLY

 

Part #

Description

 

Part#

Description

25)

*

Flex Pipe (3" ID)

38)

820-058

Pedestal Base Cover

26)

*

Clamp for Flex Pipe

39)

730-036

Gasket - Air Passage

29)

*

Air Deflector

41)

904-185

Cable Tie - High Temperature

30)

730-044

Rear Panel

42)

904-186

Cable Tie Mounting Button

31)

630-021

Fan Access Panel

 

910-033

Heat Resistant Sleeve

32)

730-028

Firebox Baffle

 

 

 

33)

630-520

False Top Assembly

 

918-089

Decal Top Rear Control Panel

36)

936-194

Gasket - Starter Collar/

 

736-969

Conversion Kit to LPG

 

 

Air Passage

 

948-216

Logo Plate

37)

936-197

Gasket - Flue Collar/

 

918-278

Manual

 

 

Starter Collar

 

 

 

 

 

 

*Not available as a replacement part.

Regency FG39 FireGenie Freestanding Gas Stove

31

Image 31
Contents Please Keep These Instructions For Future Reference ManualUnit Specifications Table of Contents Safety Label Save These Instructions InstallationSpecifications General Safety InformationCombustion and Ventilation AIR Installation ChecklistClearances to Combustibles Locating Your Regency GAS StoveFlueing Introduction Louver InstallationInstallation Precautions Safety Precautions for InstallerClearance k in mm Exterior Flue Termination LocationsFlue Restrictor Position Flue Restrictor setting at 40 Mj/h 31 Mj/hFlueing Arrangements Horizontal Terminations for All Fluing SystemsOptional DV Stove Horizontal Flue KIT #946-112 InstallationDV Stove Horizontal Flue KIT Qty. DescriptionInstallation DURA-FLUE Termination KIT Planning Your Dura-Flue InstallationDURA-FLUE Fluing Components Diagram DURA-FLUE Horizontal InstallationsHint Apply silicone to female end Hole previously drilled DURA-FLUE Vertical TerminationMastic Offset ChartCathedral Ceilings Support Extensions Round Rdse or Square SqseAeration Adjustment GAS Pipe Pressure TestingGAS Connection Jumper Location Pilot Orifice Extrusion Assembly TubeBurner Orifice Antenna Control Box CoverCable Electric Modulator Adjusting the Outlet PressureAdditional Piece pkg. with unit LOG SET InstallationConversion to Lower BTU Rating LPG Conversion Kit ContainsNotch Pins on Rear Log SupportLava rock PinCutoutOptional Remote Control Final Check Front Door InstallationPackaged separately Away from sharp edges WiringOperating Instructions Summary Controls Pilot AdjustmentNormal Operating Sounds GAS Appliances 918-332a Copy of the Lighting Plate InstructionsMaintenance Instructions MaintenanceGOLD-PLATED Doors Door Gasket LOG ReplacementLatch Adjustment Glass ReplacementFan Replacement FAN MaintenanceAlternate Fan Access Manual Switch Reset Cables Pin Ground Molex Connector WireRemoving Valve Tray Electronic Components Parts List Parts ListRegency FG39 FireGenie Freestanding Gas Stove Description Part# FG39 Main AssemblyFG39 Burner & LOG Assembly FG39 Door Assemblies Regency FG39 FireGenie Freestanding Gas Stove Exclusions WarrantyWarranty Lifetime Conditions

FG39-NG, FG39-LPG specifications

The Regency FG39 series comprises two distinct gas fireplaces, the FG39-NG (natural gas) and the FG39-LPG (propane), embodying a perfect blend of functionality, design, and efficiency. These models cater to homeowners seeking an elegant heating solution that combines aesthetic appeal with modern technology.

One of the standout features of the Regency FG39 series is its advanced burner system. Designed for maximum heat output and efficiency, the interlocking burner design produces realistic flames that enhance the ambiance of any room. The flames are adjustable, allowing users to customize their heating experience to suit their preferences and home environment. With an impressive thermal efficiency rating, these fireplaces not only provide warmth but also do so while conserving energy.

An important characteristic of the Regency FG39 series is the extensive range of customizable options available. Homeowners can choose from various decorative fronts, media options like rocks and logs, and colors that complement their interior design themes. This modular approach allows the fireplace to blend seamlessly with any decor, while still standing as a stunning focal point.

Additionally, both models feature a sleek, contemporary design with a large viewing area that maximizes the fire's visual impact. The tempered glass doors not only enhance safety but also add a touch of sophistication. The clean lines and minimalist aesthetic make these fireplaces ideal for both modern and traditional homes.

Technologically, the Regency FG39 series is equipped with high-performance ventilation systems that ensure optimal airflow and heat distribution. This allows for versatile installation options, granting homeowners the flexibility to position the unit in various spaces without compromising on performance.

Furthermore, the unit's easy-to-use digital remote control elevates the user experience. With the ability to adjust temperature settings and flame levels from anywhere in the room, comfort is easily attainable at the touch of a button.

In conclusion, the Regency FG39-NG and FG39-LPG fireplaces offer a compelling solution for homeowners looking for a combination of style, efficiency, and advanced technology. With customizable options, impressive heating systems, and sleek designs, these fireplaces represent the epitome of modern heating solutions, enhancing any living space while ensuring comfort and luxury.